Full Mimicking of Coronary Hemodynamics for Ex-Vivo Stimulation of Human Saphenous Veins

被引:0
|
作者
Marco Piola
Matthijs Ruiter
Riccardo Vismara
Valeria Mastrullo
Marco Agrifoglio
Marco Zanobini
Maurizio Pesce
Monica Soncini
Gianfranco Beniamino Fiore
机构
[1] Politecnico di Milano,Dipartimento di Elettronica, Informazione e Bioingegneria
[2] Centro Cardiologico Monzino-IRCCS,Unità di Ingegneria Tissutale
[3] Università di Milano,Dipartimento di Scienze Cliniche e di Comunità
[4] Centro Cardiologico Monzino-IRCCS,Divisione di Cardiochirurgia
来源
Annals of Biomedical Engineering | 2017年 / 45卷
关键词
Coronary flow rate; Pulsatile pressure; Saphenous vein graft disease; platform; Wall remodeling;
D O I
暂无
中图分类号
学科分类号
摘要
After coronary artery bypass grafting, structural modifications of the saphenous vein wall lead to lumen narrowing in response to the altered hemodynamic conditions. Here we present the design of a novel ex vivo culture system conceived for mimicking central coronary artery hemodynamics, and we report the results of biomechanical stimulation experiments using human saphenous vein samples. The novel pulsatile system used an aortic-like pressure for forcing a time-dependent coronary-like resistance to obtain the corresponding coronary-like flow rate. The obtained pulsatile pressures and flow rates (diastolic/systolic: 80/120 mmHg and 200/100 mL/min, respectively) showed a reliable mimicking of the complex coronary hemodynamic environment. Saphenous vein segments from patients undergoing coronary artery bypass grafting (n = 12) were subjected to stimulation in our bioreactor with coronary pulsatile pressure/flow patterns or with venous-like perfusion. After 7-day stimulation, SVs were fixed and stained for morphometric evaluation and immunofluorescence. Results were compared with untreated segments of the same veins. Morphometric and immunofluorescence analysis revealed that 7 days of pulsatile stimulation: (i) did not affect integrity of the vessel wall and lumen perimeter, (ii) significantly decreased both intima and media thickness, (iii) led to partial endothelial denudation, and (iv) induced apoptosis in the vessel wall. These data are consistent with the early vessel remodeling events involved in venous bypass adaptation to arterial flow/pressure patterns. The pulsatile system proved to be a suitable device to identify ex vivo mechanical cues leading to graft adaptation.
引用
收藏
页码:884 / 897
页数:13
相关论文
共 50 条
  • [1] Full Mimicking of Coronary Hemodynamics for Ex-Vivo Stimulation of Human Saphenous Veins
    Piola, Marco
    Ruiter, Matthijs
    Vismara, Riccardo
    Mastrullo, Valeria
    Agrifoglio, Marco
    Zanobini, Marco
    Pesce, Maurizio
    Soncini, Monica
    Fiore, Gianfranco Beniamino
    ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (04) : 884 - 897
  • [2] Histology of saphenous veins after treatment with the ClariVein® device - an ex-vivo experiment
    Kendler, Michael
    Averbeck, Marco
    Simon, Jan C.
    Ziemer, Mirjana
    JOURNAL DER DEUTSCHEN DERMATOLOGISCHEN GESELLSCHAFT, 2013, 11 (04): : 348 - 352
  • [3] Procedure for Human Saphenous Veins Ex Vivo Perfusion and External Reinforcement
    Longchamp, Alban
    Allagnat, Florent
    Berard, Xavier
    Alonso, Florian
    Haefliger, Jacques-Antoine
    Deglise, Sebastien
    Corpataux, Jean-Marc
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2014, (92):
  • [4] Role of hemodynamic forces in the ex vivo arterialization of human saphenous veins
    Berard, Xavier
    Deglise, Sebastien
    Alonso, Florian
    Saucy, Francois
    Meda, Paolo
    Bordenave, Laurence
    Corpataux, Jean-Marc
    Haefliger, Jacques-Antoine
    JOURNAL OF VASCULAR SURGERY, 2013, 57 (05) : 1371 - 1382
  • [5] Histopathological analysis of incompetent great saphenous veins after mechanochemical ablation treatment - An ex-vivo experiment
    Yang, Bo
    Nie, Qiang-Qiang
    Fan, Xue-Qiang
    Zhang, Jian-Bin
    Liu, Peng
    VASCULAR, 2022, 30 (02) : 349 - 356
  • [6] Early effects of arterial hemodynamic conditions on human saphenous veins perfused ex vivo
    Mavromatis, K
    Fukai, T
    Tate, M
    Chesler, N
    Ku, DN
    Galis, ZS
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2000, 20 (08) : 1889 - 1895
  • [7] Mechanical properties of native and ex vivo remodeled porcine saphenous veins
    Gusic, RJ
    Petko, M
    Myung, R
    Gaynor, JW
    Gooch, KJ
    JOURNAL OF BIOMECHANICS, 2005, 38 (09) : 1770 - 1779
  • [8] Ex-vivo cytokine response to stimulation in health and disease
    Nierhaus, Axel
    Frings, Daniel
    Montag, Barbara
    Linssen, Jo
    Kreymann, Georg
    SHOCK, 2008, 29 : 68 - 69
  • [9] Comparative assessment of continuous and pulsatile ex-vivo perfusion of human saphenous vein after 14 days
    Probst, H.
    Huot, F.
    Deglise, S.
    Haller, C.
    Mazzolai, L.
    Saucy, F.
    Bosman, F.
    Corpataux, J.
    BRITISH JOURNAL OF SURGERY, 2006, 93 (09) : 1170 - 1170
  • [10] A compact and automated ex vivo vessel culture system for the pulsatile pressure conditioning of human saphenous veins
    Piola, Marco
    Prandi, Francesca
    Bono, Nina
    Soncini, Monica
    Penza, Eleonora
    Agrifoglio, Marco
    Polvani, Gianluca
    Pesce, Maurizio
    Fiore, Gianfranco Beniamino
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2016, 10 (03) : E204 - E215