Detection of Breast Cancer with a Computer-Aided Detection Applied to Full-Field Digital Mammography

被引:0
|
作者
Ryusuke Murakami
Shinichiro Kumita
Hitomi Tani
Tamiko Yoshida
Kenichi Sugizaki
Tomoyuki Kuwako
Tomonari Kiriyama
Kenta Hakozaki
Emi Okazaki
Keiko Yanagihara
Shinya Iida
Shunsuke Haga
Shinichi Tsuchiya
机构
[1] Graduate School of Medicine,Department of Radiology
[2] Nippon Medical School,Department Surgery for Organ Function and Biological Regulation
[3] Graduate School of Medicine,Division of Diagnostic Pathology
[4] Nippon Medical School,undefined
[5] Nippon Medical School Hospital,undefined
来源
Journal of Digital Imaging | 2013年 / 26卷
关键词
Breast neoplasm; Cancer detection; Computer-aided diagnosis (CAD); Digital mammography;
D O I
暂无
中图分类号
学科分类号
摘要
A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, mammographic presentation, lesion size, and results of histopathological examination. The overall sensitivity of CAD was 91 % (139 of 152 cases). CAD detected 100 % (47/47) of cancers manifested as microcalcifications; 98 % (62/63) of those manifested as non-calcified masses; 100 % (15/15) of those manifested as mixed masses and microcalcifications; 75 % (12/16) of those manifested as architectural distortions, and 69 % (18/26) of those manifested as focal asymmetry. CAD sensitivity was 83 % (10/12) for cancers measuring 1–10 mm, 92 % (37/40) for those measuring 11–20 mm, and 92 % (92/100) for those measuring >20 mm. There was no significant difference in CAD detection efficiency between cancers in dense breasts (88 %; 69/78) and those in non-dense breasts (95 %; 70/74). CAD showed a high sensitivity of 91 % (139/152) for the mammographic appearance of cancer and 100 % sensitivity for identifying cancers manifested as microcalcifications. Sensitivity was not influenced by breast density or lesion size. CAD should be effective for helping radiologists detect breast cancer at an earlier stage.
引用
收藏
页码:768 / 773
页数:5
相关论文
共 50 条
  • [41] Computer-aided detection (CAD) of breast cancer on full field digital and screening film mammograms
    Sun, XJ
    Qian, W
    Song, XS
    Qian, YY
    Song, DS
    Clark, RA
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 930 - 939
  • [42] Computer-Aided Detection Systems for Digital Mammography
    Perez-Diaz, Marlen
    Orozco-Morales, Ruben
    Suarez-Aday, Eduardo
    Pirchio, Rosana
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 265 - 271
  • [43] There Is No Way That the Cancer Detection Rate for Full-Field Digital Mammography Is the Same as for Digital Breast Tomosynthesis
    Kopans, Daniel B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (01) : W46 - W46
  • [44] Computer aided detection (CAD) in direct digital full field mammography
    Friedemann, B
    Uwe, F
    Karim, B
    Silivia, O
    Eckhardt, G
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 253 - 256
  • [45] Breast Cancer: Computer-aided Detection with Digital Breast Tomosynthesis
    Morra, Lia
    Sacchetto, Daniela
    Durando, Manuela
    Agliozzo, Silvano
    Carbonaro, Luca Alessandro
    Delsanto, Silvia
    Pesce, Barbara
    Persano, Diego
    Mariscotti, Giovanna
    Marra, Vincenzo
    Fonio, Paolo
    Bert, Alberto
    RADIOLOGY, 2015, 277 (01) : 56 - 63
  • [46] Computer-aided detection in mammography
    Astley, SM
    Gilbert, FJ
    CLINICAL RADIOLOGY, 2004, 59 (05) : 390 - 399
  • [47] Reproducibility of computer-aided detection marks in digital mammography
    Kim, Seung Ja
    Moon, Woo Kyung
    Cho, Nariya
    Cha, Joo Hee
    Kim, Sun Mi
    Im, Jung-Gi
    KOREAN JOURNAL OF RADIOLOGY, 2007, 8 (03) : 198 - 205
  • [48] Computer-aided detection for architectural distortion: a comparison of digital breast tomosynthesis and digital mammography
    Li, Yue
    He, Zilong
    Ma, Xiangyuan
    Zeng, Weixiong
    Liu, Jialing
    Xu, Weimin
    Xu, Zeyuan
    Wang, Sina
    Wen, Chanjuan
    Zeng, Hui
    Wu, Jiefang
    Chen, Weiguo
    Lu, Yao
    MEDICAL IMAGING 2022: COMPUTER-AIDED DIAGNOSIS, 2022, 12033
  • [49] Comparison of computer-aided detection of clustered microcalcifications in digital mammography and digital breast tomosynthesis
    Samala, Ravi K.
    Chan, Heang-Ping
    Lu, Yao
    Hadjiiski, Lubomir
    Wei, Jun
    Helvie, Mark
    MEDICAL IMAGING 2015: COMPUTER-AIDED DIAGNOSIS, 2015, 9414
  • [50] Computer-Aided Detection and Diagnosis of Breast Cancer With Mammography: Recent Advances
    Tang, Jinshan
    Rangayyan, Rangaraj M.
    Xu, Jun
    El Naqa, Issam
    Yang, Yongyi
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2009, 13 (02): : 236 - 251