Performance evaluation of axially loaded high strength ferrocement confined fibre reinforced concrete columns
被引:0
|
作者:
Arathi Krishna
论文数: 0引用数: 0
h-index: 0
机构:SASTRA Deemed University,School of Civil Engineering
Arathi Krishna
Sreenath Sreekumaran
论文数: 0引用数: 0
h-index: 0
机构:SASTRA Deemed University,School of Civil Engineering
Sreenath Sreekumaran
Saravana Raja Mohan Kaliyaperumal
论文数: 0引用数: 0
h-index: 0
机构:SASTRA Deemed University,School of Civil Engineering
Saravana Raja Mohan Kaliyaperumal
机构:
[1] SASTRA Deemed University,School of Civil Engineering
来源:
Innovative Infrastructure Solutions
|
2024年
/
9卷
关键词:
Ferrocement;
Jacketing;
Micro fibre;
High strength mortar;
D O I:
暂无
中图分类号:
学科分类号:
摘要:
The current investigation sought to study the structural characteristics of reinforced concrete (RC) columns, focussing on the synergistic effect of ferrocement confinement and fibre-reinforced concrete cores. The primary objective of this study was to investigate the effects of incorporating high-strength mortar jacketing and steel fibre inclusion on the load-carrying capacity, ductility, and energy absorption. The findings of this research demonstrate that the load-carrying capacity of columns can be significantly enhanced through ferrocement wrapping, particularly when combined by incorporating steel fibres. The load capacity of columns confined with fibre-reinforced ferrocement showed a 51% increase, whereas columns confined with non-fibrous ferrocement displayed a 43% increase in load capacity compared to typical reinforced concrete (RC) columns. Furthermore, the analysis revealed that using steel fibres led to enhanced ductility and increased energy absorption. The columns that were confined using ferrocement and reinforced with fibre exhibited a notable boost in ductility, with a 2.9-times increase, as well as a major improvement in energy absorption, with a 3.3-fold increase, in comparison to the reference columns. The study’s findings suggest that combining ferrocement confinement and steel fibre reinforcement can significantly enhance the structural effectiveness of concrete columns, resulting in improved resilience and load-carrying capability.
机构:
Hong Kong Polytech Univ, Dept Civil & Environm Engn, Kowloon, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Dept Civil & Environm Engn, Kowloon, Hong Kong, Peoples R China
Ho, Ivy Fung-yuen
Lam, Eddie Siu-shu
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Polytech Univ, Dept Civil & Environm Engn, Kowloon, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Dept Civil & Environm Engn, Kowloon, Hong Kong, Peoples R China
Lam, Eddie Siu-shu
Wu, Bo
论文数: 0引用数: 0
h-index: 0
机构:
S China Univ Technol, Sch Architectural & Civil Engn, Guangzhou 51000052999, Guangdong, Peoples R ChinaHong Kong Polytech Univ, Dept Civil & Environm Engn, Kowloon, Hong Kong, Peoples R China
Wu, Bo
Wang, Ya-yong
论文数: 0引用数: 0
h-index: 0
机构:
China Acad Bldg Res, Beijing 100000, Peoples R ChinaHong Kong Polytech Univ, Dept Civil & Environm Engn, Kowloon, Hong Kong, Peoples R China