Application of multiple FACTS devices of similar type for congestion mitigation

被引:3
作者
Siddiqui A.S. [1 ]
Deb T. [1 ]
机构
[1] Department of Electrical Engineering, Jamia Millia Islamia, New Delhi
来源
Deb, Tanmoy (tdeb1969@gmail.com) | 1600年 / Springer卷 / 07期
关键词
Congestion; Deregulated power system; Multiple FACTS devices;
D O I
10.1007/s13198-014-0262-1
中图分类号
学科分类号
摘要
FACTS (flexible AC transmission system) devices can increase line loadability by altering transmission line parameters. Use of multiple FACTS devices can reduce congestion in heavily loaded lines, reduce system loss, improve stability and hence reduce cost of energy delivery. This paper examines the effect of multiple FACTS devices of similar type on congestion mitigation. The system has been tested with a series FACTS device (TCSC), a shunt FACTS device (STATCOM) and a combined series & shunt FACTS device (UPFC). The proposal has been demonstrated on IEEE-14 bus system. © 2014, The Society for Reliability Engineering, Quality and Operations Management (SREQOM), India and The Division of Operation and Maintenance, Lulea University of Technology, Sweden.
引用
收藏
页码:387 / 397
页数:10
相关论文
共 10 条
[1]  
Azadani E.N., Hosseinion S.H., Janati M., Hasanpor P., Optimal placement of multiple STATCOM, Proceedings of the IEEE international middle-east conference, 2007, pp. 523-528, (2008)
[2]  
Chakraborty A.K., Majundas S., Chattopadhayay P.K., Nandi C., Active line flow control of power system network with FACTS devices of choice using soft computing technique, Int J Comput Appl, 25, 9, pp. 14-21, (2011)
[3]  
Esmaeili A., Esmaeili S., A new multi objective optimal allocation of multi-type FACTS devices for total transfer capability enhancement and improving line congestion using harmony search algorithm, Turk J Electr Eng Comput Sci, 21, pp. 957-979, (2013)
[4]  
Gerbex S., Optimal location of multi type FACTS devices in a power system by means of genetic algorithm, IEEE Trans Power Syst, 16, 3, pp. 537-544, (2001)
[5]  
Gitizadeh M., Allocation of multi type FACTS devices using multi objective genetic algorithm approach for power system rainforest, J Electr Eng, 92, 6, pp. 227-237, (2010)
[6]  
Mohammad Idris R., Khairuddin A., Mustafa M.W., The placement of FACTS devices in modern electrical network using pries algorithm, Proceedings of the 9th WSEAS international conference on applications of electrical engineering, (2010)
[7]  
Rahimzadeh S., Bina Tankoli M., Viki A., Simultaneous application of multi type FACTS devices to the restructured environment–achieving both optimal number & location, Gener Trans Distrib IET, 4, 3, pp. 349-362, (2010)
[8]  
Rashed G.T., Shaheem H.T., Cheng S.J., (2007) Optimal location and parameter setting of multiple TCSC for increasing power system load ability based on GAPSO techniques, Proceedings of the IEEE international computation conference, 4, pp. 335-344, (2007)
[9]  
Saravanan M., Slochanal S.M.R., Ventakash P., Prince J., Abraham S., Application of particle swarm optimization technique for optimal location of FACTS devices considering cost of installation & system loadability, Electr Power Syst Res, 77, pp. 276-286, (2007)
[10]  
Tabatabaei N.M., Aghajani G.H., Boushehri N.S., Shoarinejad S., Optimal location of FACTS devices using adaptive particle swarm optimization mixed with simulated annealing, Int J Tech Phys Probl Eng, 3, 7, pp. 60-70, (2011)