Measurements of soot volume fraction in pulsed diffusion flame by laser induced incandescence

被引:0
|
作者
Hayri Sapmaz
Cheng-Xian Lin
Chaouki Ghenai
机构
[1] Boston Scientific,Department of Mechanical, Aerospace, and Biomedical Engineering
[2] University of Tennessee,Department of Mechanical Engineering, College of Engineering and Computer Science
[3] Florida Atlantic University,undefined
来源
Experiments in Fluids | 2008年 / 44卷
关键词
Strouhal Number; Soot Particle; Soot Formation; Soot Volume Fraction; Laser Induce Incandescence;
D O I
暂无
中图分类号
学科分类号
摘要
Laser induced incandescence (LII) is used in this study to measure soot volume fractions in steady and pulsed laminar diffusion flame. The main objective of this study is to investigate the effect of flame pulsing on soot formation inside the flame region. Phase-locked soot images were obtained for flame pulsing frequency between 10 and 200 Hz. The phase-locked soot images revealed the entire motion process of the soot field during one pulsation period. The results showed that the total soot volume fraction in the flame region increased by 45% when the pulsing frequency was increased from 10 to 200 Hz.
引用
收藏
页码:137 / 144
页数:7
相关论文
共 50 条
  • [1] Measurements of soot volume fraction in pulsed diffusion flame by laser induced incandescence
    Sapmaz, Hayri
    Lin, Cheng-Xian
    Ghenai, Chaouki
    EXPERIMENTS IN FLUIDS, 2008, 44 (01) : 137 - 144
  • [2] Soot volume fraction and particle size measurements with laser-induced incandescence
    Mewes, B
    Seitzman, JM
    APPLIED OPTICS, 1997, 36 (03): : 709 - 717
  • [3] Calibration and correction of laser-induced incandescence for soot volume fraction measurements
    Choi, MY
    Jensen, KA
    COMBUSTION AND FLAME, 1998, 112 (04) : 485 - 491
  • [4] TWO-DIMENSIONAL IMAGING OF SOOT VOLUME FRACTION IN PULSED DIFFUSION FLAMES BY LASER-INDUCED INCANDESCENCE
    Sapmaz, H.
    Ghenai, C.
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER CONFERENCE, VOL 1, PTS A AND B, 2006, : 1405 - 1409
  • [5] SPATIALLY-RESOLVED MEASUREMENTS OF SOOT VOLUME FRACTION USING LASER-INDUCED INCANDESCENCE
    QUAY, B
    LEE, TW
    NI, T
    SANTORO, RJ
    COMBUSTION AND FLAME, 1994, 97 (3-4) : 384 - 392
  • [6] Soot Volume Fraction Measurements by Auto-Compensating Laser-Induced Incandescence in Diffusion Flames Generated by Ethylene Pool Fire
    Cruz, Juan J.
    Verdugo, Ignacio
    Gutierrez-Caceres, Nicolas
    Escudero, Felipe
    Demarco, Rodrigo
    Liu, Fengshan
    Yon, Jerome
    Chen, Dongping
    Fuentes, Andres
    FRONTIERS IN MECHANICAL ENGINEERING-SWITZERLAND, 2021, 7
  • [7] Soot Volume Fraction Measurements in a Gasoline Direct Injection Engine by Combined Laser Induced Incandescence and Laser Extinction Method
    de Francqueville, Loic
    Bruneaux, Gilles
    Thirouard, Benoist
    SAE INTERNATIONAL JOURNAL OF ENGINES, 2010, 3 (01) : 163 - 182
  • [8] Absorption correction of two-color laser-induced incandescence signals for soot volume fraction measurements
    Migliorini, Francesca
    De Iuliis, Silvana
    Cignoli, Francesco
    Zizak, Giorgio
    APPLIED OPTICS, 2006, 45 (29) : 7706 - 7711
  • [9] Comparative measurements of soot particles by laser induced incandescence in premixed and diffusion flames
    McManus, KR
    Rawlins, WT
    Allen, MG
    CHEMICAL AND PHYSICAL PROCESSES IN COMBUSTION, 1997, : 43 - 46
  • [10] Planar 2-color time-resolved laser-induced incandescence measurements of soot in a diffusion flame
    Tian, B.
    Zhang, C.
    Gao, Y.
    Hochgreb, S.
    AEROSOL SCIENCE AND TECHNOLOGY, 2017, 51 (12) : 1345 - 1353