Central venous pulse pressure analysis using an R-Synchronized pressure measurement system

被引:4
作者
Fujita Y. [1 ]
Hayashi D. [1 ]
Wada S. [1 ]
Yoshioka N. [1 ]
Yasukawa T. [1 ]
Pestel G. [2 ]
机构
[1] Department of Anesthesiology, ICM, Kawasaki Medical School, Kurashiki-city, Okayama 701-0192
[2] Department of Anesthesiology, Bern University Hospital (Inselspital), Bern
关键词
Blood pressure; Central venous pressure. Equipment; Computer; Monitor;
D O I
10.1007/s10877-006-9035-y
中图分类号
学科分类号
摘要
Objective. The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Methods. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expir ation were compared, and CVP waveform components were measured using this system. Results. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8±0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6±0.7 mmHgand-0.9±0.5 mmHg, respectively), with a mean pulse pressure of 3.4 mmHg. The difference between the mean CVP and CV Patend-diastole during expiration was 0.58±0.81 mmHg. Conclusions. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology. © Springer Science+Business Media, Inc. 2006.
引用
收藏
页码:385 / 389
页数:4
相关论文
共 50 条
[31]   The effects of repeated occlusion measurement on blood pressure and pulse rate [J].
Tomaka, J ;
Palacios-Esquivel, R ;
Concha, JB .
INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 1998, 30 (03) :353-358
[32]   Brachial vs. Central Systolic Pressure and Pulse Wave Transmission Indicators: A Critical Analysis [J].
Izzo, Joseph L., Jr. .
AMERICAN JOURNAL OF HYPERTENSION, 2014, 27 (12) :1433-1442
[33]   Continuous blood pressure monitoring during exercise using pulse wave transit time measurement [J].
Lass, J ;
Meigas, K ;
Karai, D ;
Kattai, R ;
Kaik, J ;
Rossmann, M .
PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 :2239-2242
[34]   Continuous blood pressure measurement using pulse transit timeKontinuierliche Blutdruckmessung anhand der Pulstransitzeit [J].
A. Hennig ;
A. Patzak .
Somnologie - Schlafforschung und Schlafmedizin, 2013, 17 (2) :104-110
[35]   Intrauterine growth restriction increases blood pressure and central pulse pressure measured with telemetry in aging rats [J].
Schreuder, Michiel F. ;
van Wijk, Joanna A. E. ;
Delemarre-van de Waal, Henriette A. .
JOURNAL OF HYPERTENSION, 2006, 24 (07) :1337-1343
[36]   A NEW APPROACH OF DYNAMIC BLOOD PRESSURE MEASUREMENT BASED ON THE TIME DOMAIN ANALYSIS OF THE PULSE WAVE [J].
Su Zimei ;
Xu Wei ;
Yu Hui ;
Du Fei ;
Wang Jicun ;
Xu Kexin .
POWER CONTROL AND OPTIMIZATION, PROCEEDINGS, 2009, 1159 :195-+
[37]   Pulse Wave Calibration and Implications for Blood Pressure Measurement: Systematic Review and Meta-Analysis [J].
Jedrzejewski, Dawid ;
McFarlane, Ewan ;
Lacy, Peter S. ;
Williams, Bryan .
HYPERTENSION, 2021, 78 (02) :360-371
[38]   Comparison of brachial artery pressure and derived central pressure in the measurement of abdominal aortic aneurysm distensibility [J].
Wilson, K ;
MacCallum, H ;
Wilkinson, IB ;
Hoskins, PR ;
Lee, AJ ;
Bradbury, AW .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2001, 22 (04) :355-360
[39]   Continuous blood pressure measurement system based on low cuff pressure approach [J].
Ding, Cang-Yi ;
Huang, Cheng-Ning ;
Yu, Fang-Ming ;
Chung, Hung-Yuan .
PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-8, 2007, :776-+
[40]   Reductions in central venous pressure by lower body negative pressure or blood loss elicit similar hemodynamic responses [J].
Johnson, Blair D. ;
van Helmond, Noud ;
Curry, Timothy B. ;
van Buskirk, Camille M. ;
Convertino, Victor A. ;
Joyner, Michael J. .
JOURNAL OF APPLIED PHYSIOLOGY, 2014, 117 (02) :131-141