Central venous pulse pressure analysis using an R-Synchronized pressure measurement system

被引:3
作者
Fujita Y. [1 ]
Hayashi D. [1 ]
Wada S. [1 ]
Yoshioka N. [1 ]
Yasukawa T. [1 ]
Pestel G. [2 ]
机构
[1] Department of Anesthesiology, ICM, Kawasaki Medical School, Kurashiki-city, Okayama 701-0192
[2] Department of Anesthesiology, Bern University Hospital (Inselspital), Bern
关键词
Blood pressure; Central venous pressure. Equipment; Computer; Monitor;
D O I
10.1007/s10877-006-9035-y
中图分类号
学科分类号
摘要
Objective. The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Methods. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expir ation were compared, and CVP waveform components were measured using this system. Results. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8±0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6±0.7 mmHgand-0.9±0.5 mmHg, respectively), with a mean pulse pressure of 3.4 mmHg. The difference between the mean CVP and CV Patend-diastole during expiration was 0.58±0.81 mmHg. Conclusions. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology. © Springer Science+Business Media, Inc. 2006.
引用
收藏
页码:385 / 389
页数:4
相关论文
共 50 条
  • [21] MEASUREMENT OF SYSTOLIC BLOOD-PRESSURE USING PULSE OXIMETRY DURING HELICOPTER FLIGHT
    TALKE, PO
    CRITICAL CARE MEDICINE, 1991, 19 (07) : 934 - 937
  • [22] A novel calibration method for noninvasive blood pressure measurement using pulse transit time
    Yan, Y. S.
    Zhang, Y. T.
    2007 4TH IEEE/EMBS INTERNATIONAL SUMMER SCHOOL AND SYMPOSIUM ON MEDICAL DEVICES AND BIOSENSORS, 2007, : 1 - +
  • [23] Development of Pulse and Blood Pressure Monitoring System
    Salah, Wael A.
    Abu Sneineh, Anees
    2018 IEEE SYMPOSIUM ON COMPUTER APPLICATIONS & INDUSTRIAL ELECTRONICS (ISCAIE 2018), 2018, : 37 - 42
  • [24] Diurnal changes in central blood pressure and pulse pressure amplification in patients with obstructive sleep apnoea
    Serinel, Yasmina
    Hoyos, Camilla
    Qasem, Ahmad
    Yee, Brendon J.
    Grunstein, Ronald R.
    Wong, Keith H.
    Phillips, Craig L.
    INTERNATIONAL JOURNAL CARDIOLOGY HYPERTENSION, 2019, 1
  • [25] A Compound Pressure Signal Acquisition System for Multichannel Wrist Pulse Signal Analysis
    Wang, Peng
    Zuo, Wangmeng
    Zhang, David
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (06) : 1556 - 1565
  • [26] Central pulse pressure is inversely associated with proximal aortic remodelling
    Tosello, Francesco
    Guala, Andrea
    D'ascenzo, Fabrizio
    Bollati, Martina
    Leone, Dario
    Sabia, Luca
    Bruno, Giulia
    Mingrone, Giulia
    Astarita, Anna
    Vallelonga, Fabrizio
    Avenatti, Eleonora
    Moretti, Claudio
    Veglio, Franco
    Ridolfi, Luca
    Milan, Alberto
    JOURNAL OF HYPERTENSION, 2021, 39 (05) : 919 - 925
  • [27] Wearable blood pressure measurement device using cuffless blood pressure measurement methods
    Dohi T.
    Waki K.
    IEEJ Transactions on Sensors and Micromachines, 2016, 136 (09) : 370 - 376
  • [28] Improved Assessment of Hypertensive Related Brain Insults in Late Life Using Central Pulse Pressure
    King, Kevin S.
    HYPERTENSION, 2020, 75 (02) : 295 - 296
  • [29] Continuous Noninvasive blood pressure measurement by pulse transit time
    Fung, P
    Dumont, G
    Ries, C
    Mott, C
    Ansermino, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 738 - 741
  • [30] The effects of repeated occlusion measurement on blood pressure and pulse rate
    Tomaka, J
    Palacios-Esquivel, R
    Concha, JB
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 1998, 30 (03) : 353 - 358