Establishment of reference intervals and transfusion criterion for Sonoclot analysis

被引:0
|
作者
Zhen-lu Zhang
You-ping Chen
Cui-hua Tao
Xiao-hui Liu
Meng-ya Li
Xin Zhou
机构
[1] Zhongnan Hospital of Wuhan University,Department of Laboratory Medicine
[2] Wuhan Asia Heart Hospital of Wuhan University,Department of Pathology
[3] Wuhan Asia Heart Hospital of Wuhan University,Department of Transfusion
[4] Wuhan Asia Heart Hospital of Wuhan University,Department of Laboratory Medicine
[5] Wuhan Asia Heart Hospital of Wuhan University,Department of Cardiology
来源
Journal of Huazhong University of Science and Technology [Medical Sciences] | 2016年 / 36卷
关键词
Sonoclot analyzer; reference interval; transfusion criterion;
D O I
暂无
中图分类号
学科分类号
摘要
Sonoclot analyzer has been widely used in many countries. But the reference intervals provided by the manufacturer were derived from only 45 participants, and there was no cut-off value for transfusion for Sonoclot analysis. This study aimed to establish reference intervals and transfusion criterion for Sonoclot analysis. Volunteers were recruited from healthy Chinese adults and patients undergoing cardiac surgery. Blood samples were withdrawn from forearm vein and measured for activated clotting time (ACT), clot rate (CR), platelet function (PF), activated partial thromboplastin time (APTT), fibrinogen concentration (FIB), and platelet count (PLT). The reference intervals were determined by the nonparametric method. Cut-off values were determined by the receiver operating characteristics curve. A total of 135 healthy volunteers and 281 patients were enrolled. The 95% reference intervals were 96–195 s, 22–51 signal U/min, >1.6 for ACT, CR, PF respectively. In the 281 patients, the results of APTT, FIB, PLT, ACT, CR, and PF ranged from 20.5–300.0 s, 0.28–4.11 g/L, (19.0–387.3)×109/L, 80–514 s, 2.9–74 signal U/min, and 0.1–5.1 respectively. The cut-off values for transfusion were >208, ≤14, and ≤1.3 for ACT, CR, PF respectively. The cut-off values of Sonoclot analysis were within the manufacturer’s reference intervals, while they were outside the reference intervals established in this study. The results suggested that the manufacturer’s reference intervals were not suitable for Chinese. The reference intervals and cut-off values established in this study will be helpful to Chinese patients.
引用
收藏
页码:614 / 617
页数:3
相关论文
共 50 条
  • [41] Establishment of haemoglobin A2 reference intervals in Pretoria, South Africa: A retrospective secondary data analysis
    Nieuwenhuizen, Cailin
    Netshidzivhani, Tshiphiri
    Potgieter, Johan
    AFRICAN JOURNAL OF LABORATORY MEDICINE, 2022, 11 (01)
  • [42] Establishment of reference intervals for free light chains and immunoglobulins in Saudi population
    Borai, Anwar
    Ichihara, Kiyoshi
    Tamimi, Waleed
    Masaud, Abdulaziz
    Sobki, Samia
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (03) : 522 - 529
  • [43] Establishment of reference intervals for markers of fetal thyroid status in amniotic fluid
    Singh, PK
    Parvin, CA
    Gronowski, AM
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2003, 88 (09): : 4175 - 4179
  • [44] Establishment of reference intervals of clinical chemistry analytes for the adult population in Egypt
    Baz, Heba
    Ichihara, Kiyoshi
    Selim, May
    Awad, Ahmed
    Aglan, Sarah
    Ramadan, Dalia
    Hassab, Amina
    Mansour, Lamia
    Elgaddar, Ola
    PLOS ONE, 2021, 16 (03):
  • [45] Establishment of reference intervals for immunoassay analytes of adult population in Saudi Arabia
    Borai, Anwar
    Ichihara, Kiyoshi
    Masaud, Abdulaziz
    Tamimi, Waleed
    Bahijri, Suhad
    Armbruster, David
    Kawano, Reo
    Baarmah, Ziad
    Joatar, Faris
    Almohammadi, Mohammed
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (08) : 1302 - 1313
  • [46] Standardization of laboratory data and establishment of reference intervals in the fukuoka prefecture: A Japanese perspective
    Kinoshita, S
    Toyofuku, M
    Iida, H
    Wakiyama, M
    Kurihara, M
    Nakahara, M
    Nakata, M
    Nakashima, K
    Seo, S
    Hosaka, N
    Yano, J
    Mizumoto, T
    Ishihara, H
    Ikeda, K
    Tsuchihashi, M
    Kawashima, H
    Imoto, Y
    Imamura, K
    Urabe, Y
    Shinohara, K
    Ooishi, K
    Abe, T
    Jinnouchi, J
    Hyoudou, K
    Kondo, S
    Kobayashi, T
    Ono, J
    Hamasaki, N
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2001, 39 (03) : 256 - 262
  • [47] Establishment of reference intervals blood parameters wintering operators based measurement uncertainty
    Vyacheslav, Kuzovyk
    Olena, Bulygina
    Karyna, Bezvershniuk
    2019 IEEE 8TH INTERNATIONAL CONFERENCE ON ADVANCED OPTOELECTRONICS AND LASERS (CAOL), 2019, : 728 - 731
  • [48] Analyses of laboratory data and establishment of reference values and intervals for healthy elderly people
    Kubota, K.
    Kadomura, T.
    Ohta, K.
    Koyama, K.
    Okuda, H.
    Kobayashi, M.
    Ishii, C.
    Fujiwara, Y.
    Nishioka, T.
    Ohmae, Y.
    Ohmae, T.
    Kitajima, M.
    JOURNAL OF NUTRITION HEALTH & AGING, 2012, 16 (04): : 412 - 416
  • [49] Establishment of Reference Intervals for Bone Turnover Biomarkers in Healthy Populations in Northern China
    Huo, Lijing
    Liu, Xuexin
    Wei, Changmei
    Yu, Fang
    Ren, Luping
    Tie, Yanqing
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2024, 17 : 3955 - 3965
  • [50] Establishment of reference intervals for nonfasting lipid profile: Our experience in Indian subcontinent
    Saharia, G. K.
    Mangaraj, M.
    CLINICA CHIMICA ACTA, 2022, 530 : S281 - S282