Establishment of reference intervals and transfusion criterion for Sonoclot analysis

被引:0
|
作者
Zhen-lu Zhang
You-ping Chen
Cui-hua Tao
Xiao-hui Liu
Meng-ya Li
Xin Zhou
机构
[1] Zhongnan Hospital of Wuhan University,Department of Laboratory Medicine
[2] Wuhan Asia Heart Hospital of Wuhan University,Department of Pathology
[3] Wuhan Asia Heart Hospital of Wuhan University,Department of Transfusion
[4] Wuhan Asia Heart Hospital of Wuhan University,Department of Laboratory Medicine
[5] Wuhan Asia Heart Hospital of Wuhan University,Department of Cardiology
来源
Journal of Huazhong University of Science and Technology [Medical Sciences] | 2016年 / 36卷
关键词
Sonoclot analyzer; reference interval; transfusion criterion;
D O I
暂无
中图分类号
学科分类号
摘要
Sonoclot analyzer has been widely used in many countries. But the reference intervals provided by the manufacturer were derived from only 45 participants, and there was no cut-off value for transfusion for Sonoclot analysis. This study aimed to establish reference intervals and transfusion criterion for Sonoclot analysis. Volunteers were recruited from healthy Chinese adults and patients undergoing cardiac surgery. Blood samples were withdrawn from forearm vein and measured for activated clotting time (ACT), clot rate (CR), platelet function (PF), activated partial thromboplastin time (APTT), fibrinogen concentration (FIB), and platelet count (PLT). The reference intervals were determined by the nonparametric method. Cut-off values were determined by the receiver operating characteristics curve. A total of 135 healthy volunteers and 281 patients were enrolled. The 95% reference intervals were 96–195 s, 22–51 signal U/min, >1.6 for ACT, CR, PF respectively. In the 281 patients, the results of APTT, FIB, PLT, ACT, CR, and PF ranged from 20.5–300.0 s, 0.28–4.11 g/L, (19.0–387.3)×109/L, 80–514 s, 2.9–74 signal U/min, and 0.1–5.1 respectively. The cut-off values for transfusion were >208, ≤14, and ≤1.3 for ACT, CR, PF respectively. The cut-off values of Sonoclot analysis were within the manufacturer’s reference intervals, while they were outside the reference intervals established in this study. The results suggested that the manufacturer’s reference intervals were not suitable for Chinese. The reference intervals and cut-off values established in this study will be helpful to Chinese patients.
引用
收藏
页码:614 / 617
页数:3
相关论文
共 50 条
  • [21] Establishment of reference intervals of complete blood count for twin pregnancy
    Yifan Zeng
    Lei Li
    Man Mao
    Xinghua Liang
    Min Chen
    Yong Xia
    Wenyin He
    BMC Pregnancy and Childbirth, 21
  • [22] Establishment of reference intervals for thyroid function tests during pregnancy
    Amari, K. Mourabit
    Bondaz, L.
    Girouard, J.
    Gagnon, C.
    Weisnagel, J.
    Forest, J-C
    Giguere, Y.
    CLINICAL BIOCHEMISTRY, 2012, 45 (13-14) : 1114 - 1114
  • [23] Acute phase proteins in healthy goats: Establishment of reference intervals
    Heller, Meera C.
    Johns, Jennifer L.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2015, 27 (02) : 177 - 181
  • [24] Establishment of reference intervals for serum and salivary cortisol in Kano, Nigeria
    Mansur, R.
    Ibrahim, Z. U.
    Abdulsalam, K.
    Mohammed, I. Y.
    Sheriff, S.
    Aliyu, M. H.
    CLINICA CHIMICA ACTA, 2024, 558
  • [25] Establishment of Normal Reference Intervals for Coagulation Test Indicators in Children
    Li, Zhe
    Lou, Jintu
    Chen, Lin
    CLINICAL LABORATORY, 2024, 70 (02) : 378 - 383
  • [26] Establishment of Reference Intervals of Serum Immunoglobulins in Healthy Korean Adults
    Jang, Jae-Hyuk
    Woo, Seong-Dae
    Lee, Youngsoo
    Shin, Yoo-Seob
    Ye, Young-Min
    Park, Hae-Sim
    ALLERGY ASTHMA & IMMUNOLOGY RESEARCH, 2021, 13 (04) : 671 - 674
  • [27] Distribution of serum amyloid A and establishment of reference intervals in healthy adults
    Liu, Qian
    Li, Yan
    Yang, Fumeng
    Xu, Tongdao
    Yao, Li
    Sun, Jin
    Liang, Wei
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2020, 34 (04)
  • [28] Establishment of pediatric reference intervals on a large cohort of healthy children
    Southcott, Emma K.
    Kerrigan, Jennifer L.
    Potter, Julia M.
    Telford, Richard D.
    Waring, Paul
    Reynolds, Graham J.
    Lafferty, Antony R. A.
    Hickman, Peter E.
    CLINICA CHIMICA ACTA, 2010, 411 (19-20) : 1421 - 1427
  • [29] Retinol and α-tocopherol in pregnancy: Establishment of reference intervals and associations with CBC
    Liu, Jingrui
    Zhan, Sien
    Jia, Yan
    Li, Youran
    Liu, Ying
    Dong, Ying
    Tang, Guodong
    Li, Lin
    Zhai, Yanhong
    Cao, Zheng
    MATERNAL AND CHILD NUTRITION, 2020, 16 (03):
  • [30] Establishment of Pediatric Reference Intervals for Routine Laboratory Tests in Korean Population: A Retrospective Multicenter Analysis
    Sung, Ji Yeon
    Seo, Jong Do
    Ko, Dae-Hyun
    Park, Min-Jeong
    Hwang, Sang Mee
    Oh, Sohee
    Chun, Sail
    Seong, Moon-Woo
    Song, Junghan
    Song, Sang Hoon
    Park, Sung Sup
    ANNALS OF LABORATORY MEDICINE, 2021, 41 (02) : 155 - +