Establishment of reference intervals and transfusion criterion for Sonoclot analysis

被引:0
|
作者
Zhen-lu Zhang
You-ping Chen
Cui-hua Tao
Xiao-hui Liu
Meng-ya Li
Xin Zhou
机构
[1] Zhongnan Hospital of Wuhan University,Department of Laboratory Medicine
[2] Wuhan Asia Heart Hospital of Wuhan University,Department of Pathology
[3] Wuhan Asia Heart Hospital of Wuhan University,Department of Transfusion
[4] Wuhan Asia Heart Hospital of Wuhan University,Department of Laboratory Medicine
[5] Wuhan Asia Heart Hospital of Wuhan University,Department of Cardiology
来源
Journal of Huazhong University of Science and Technology [Medical Sciences] | 2016年 / 36卷
关键词
Sonoclot analyzer; reference interval; transfusion criterion;
D O I
暂无
中图分类号
学科分类号
摘要
Sonoclot analyzer has been widely used in many countries. But the reference intervals provided by the manufacturer were derived from only 45 participants, and there was no cut-off value for transfusion for Sonoclot analysis. This study aimed to establish reference intervals and transfusion criterion for Sonoclot analysis. Volunteers were recruited from healthy Chinese adults and patients undergoing cardiac surgery. Blood samples were withdrawn from forearm vein and measured for activated clotting time (ACT), clot rate (CR), platelet function (PF), activated partial thromboplastin time (APTT), fibrinogen concentration (FIB), and platelet count (PLT). The reference intervals were determined by the nonparametric method. Cut-off values were determined by the receiver operating characteristics curve. A total of 135 healthy volunteers and 281 patients were enrolled. The 95% reference intervals were 96–195 s, 22–51 signal U/min, >1.6 for ACT, CR, PF respectively. In the 281 patients, the results of APTT, FIB, PLT, ACT, CR, and PF ranged from 20.5–300.0 s, 0.28–4.11 g/L, (19.0–387.3)×109/L, 80–514 s, 2.9–74 signal U/min, and 0.1–5.1 respectively. The cut-off values for transfusion were >208, ≤14, and ≤1.3 for ACT, CR, PF respectively. The cut-off values of Sonoclot analysis were within the manufacturer’s reference intervals, while they were outside the reference intervals established in this study. The results suggested that the manufacturer’s reference intervals were not suitable for Chinese. The reference intervals and cut-off values established in this study will be helpful to Chinese patients.
引用
收藏
页码:614 / 617
页数:3
相关论文
共 50 条
  • [1] Establishment of reference intervals and transfusion criterion for Sonoclot analysis
    Zhang, Zhen-lu
    Chen, You-ping
    Tao, Cui-hua
    Liu, Xiao-hui
    Li, Meng-ya
    Zhou, Xin
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2016, 36 (04) : 614 - 617
  • [2] Establishment of reference intervals in Indian population
    Tester F. Ashavaid
    Seema P. Todur
    Alpa J. Dherai
    Indian Journal of Clinical Biochemistry, 2005, 20 (2) : 110 - 118
  • [3] Establishment of paediatric biochemical reference intervals
    Brinkworth, RSA
    Whitham, E
    Nazeran, H
    ANNALS OF CLINICAL BIOCHEMISTRY, 2004, 41 : 321 - 329
  • [4] ESTABLISHMENT OF REFERENCE INTERVALS IN INDIAN POPULATION
    Ashavaid, Tester F.
    Todur, Seema P.
    Dherai, Alpa J.
    INDIAN JOURNAL OF CLINICAL BIOCHEMISTRY, 2005, 20 (02) : 110 - 118
  • [5] Pediatric reference intervals: Critical gap analysis and establishment of a national initiative
    Abdelhaleem, Mohamed
    Adeli, Khosrow
    Bamforth, Fiona
    Callahan, John
    Chan, Anthony
    Chan, Pak Cheung
    Delvin, Edgard
    Dooley, Kent
    Fu, Lei
    Grey, Vijaylaxmi
    Kahr, Walter
    Lepage, Nathalie
    Lyon, Martha
    Meng, Qing
    Potter, Murray
    Verjee, Zulfikaral
    CLINICAL BIOCHEMISTRY, 2006, 39 (06) : 559 - 560
  • [6] Establishment of pediatric reference intervals for bone markers
    Huang, Y.
    Eapen, E.
    Steele, S.
    Grey, V.
    CLINICAL BIOCHEMISTRY, 2011, 44 (13) : 1172 - 1172
  • [7] On establishment of common reference intervals in laboratory medicine
    Petersen, PH
    Fraser, CG
    Ricos, C
    Stockl, D
    Libeer, JC
    Baadenhuijsen, H
    Thienpont, L
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1996, 34 (06): : 515 - 516
  • [8] The Establishment of Adult Reference Intervals on Fructosamine in Beijing
    Chen, Xun
    Wu, Jing
    Li, Ronghai
    Wang, Qingyong
    Tang, Yufeng
    Shang, Xiaohong
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2016, 30 (06) : 1051 - 1055
  • [9] Establishment and verification of reference intervals for blood cell analysis in extremely high altitude
    Yuan, Zhimin
    Zhuang, Jian
    FRONTIERS IN PHYSIOLOGY, 2024, 15
  • [10] Establishment of reference intervals for bone markers in children and adolescents
    Huang, Yun
    Eapen, Esther
    Steele, Susan
    Grey, Vijaylaxmi
    CLINICAL BIOCHEMISTRY, 2011, 44 (10-11) : 771 - 778