Autonomous microfluidic multi-channel chip for real-time PCR with integrated liquid handling

被引:0
作者
Olivier Frey
Sonja Bonneick
Andreas Hierlemann
Jan Lichtenberg
机构
[1] University of Neuchâtel,Sensors, Actuators and Microsystems Laboratory, Institute of Microtechnology
[2] ETH Zurich,Physical Electronics Laboratory
来源
Biomedical Microdevices | 2007年 / 9卷
关键词
PCR; Microchip PCR; Sample shuttling; PDMS; Diffuser nozzle structures;
D O I
暂无
中图分类号
学科分类号
摘要
We report on a novel, polymer-based, multi-channel device for polymerase chain reaction that combines, for the first time, rapid sample processing in less than 5 min with high throughput at low costs. This is achieved by sample shuttling, during which submicroliter sample plugs (∼100 nl) are oscillated rapidly over three constant-temperature zones by pneumatic actuation with integrated system. The accuracy and the speed of the liquid handling have been significantly increased, while the design of the device can be kept very simple and allows for mass production using conventional low-cost polymer fabrication processes. Massive parallelization can lead to a throughput up to 100 samples in 10 min including the preparation time. The amplification can be optically monitored by means of online fluorescence detection. Successful real-time PCR and the determination of the threshold cycle, Ct, using the developed device were demonstrated with plasmid DNA in a fluorescent real-time format.
引用
收藏
页码:711 / 718
页数:7
相关论文
共 32 条
[21]   Deep Domain Adaptation Enhances Amplification Curve Analysis for Single-Channel Multiplexing in Real-Time PCR [J].
Mao, Ye ;
Xu, Ke ;
Miglietta, Luca ;
Kreitmann, Louis ;
Moser, Nicolas ;
Georgiou, Pantelis ;
Holmes, Alison ;
Rodriguez-Manzano, Jesus .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (06) :3093-3103
[22]   Miniature on-chip detection of unpurified methicillin-resistant Staphylococcus aureus (MRSA) DNA using real-time PCR [J].
House, Dustin L. ;
Chon, Chan Hee ;
Creech, C. Buddy ;
Skaar, Eric P. ;
Li, Dongqing .
JOURNAL OF BIOTECHNOLOGY, 2010, 146 (03) :93-99
[23]   Multi-target plasmid controls for conventional and real-time PCR-based serotyping of Streptococcus pneumoniae [J].
Schembri, Jack ;
Gillis, Hayley D. ;
Lang, Amanda L. S. ;
Warhuus, Michelle ;
Martin, Irene ;
Demczuk, Walter ;
ElSherif, May ;
McNeil, Shelly A. ;
LeBlanc, Jason J. .
PLASMID, 2018, 98 :45-51
[24]   Regenerable bead-based microfluidic device with integrated thin-film photodiodes for real-time monitoring of DNA detection [J].
Caneira, Catarina R. F. ;
Santos, Denis R. ;
Chu, Virginia ;
Conde, Joao P. .
SENSORS AND ACTUATORS B-CHEMICAL, 2022, 359
[25]   Comparative analytical evaluation of the respiratory TaqMan Array Card with real-time PCR and commercial multi-pathogen assays [J].
Harvey, John J. ;
Chester, Stephanie ;
Burke, Stephen A. ;
Ansbro, Marisela ;
Aden, Tricia ;
Gose, Remedios ;
Sciulli, Rebecca ;
Bai, Jing ;
DesJardin, Lucy ;
Benfer, Jeffrey L. ;
Hall, Joshua ;
Smole, Sandra ;
Doan, Kimberly ;
Popowich, Michael D. ;
St George, Kirsten ;
Quinlan, Tammy ;
Halse, Tanya A. ;
Li, Zhen ;
Perez-Osorio, Ailyn C. ;
Glover, William A. ;
Russell, Denny ;
Reisdorf, Erik ;
Whyte, Thomas, Jr. ;
Whitaker, Brett ;
Hatcher, Cynthia ;
Srinivasan, Velusamy ;
Tatti, Kathleen ;
Tondella, Maria Lucia ;
Wang, Xin ;
Winchell, Jonas M. ;
Mayer, Leonard W. ;
Jernigan, Daniel ;
Mawle, Alison C. .
JOURNAL OF VIROLOGICAL METHODS, 2016, 228 :151-157
[26]   A polymer microfluidic chip for quantitative detection of multiple water- and foodborne pathogens using real-time fluorogenic loop-mediated isothermal amplification [J].
Tourlousse, Dieter M. ;
Ahmad, Farhan ;
Stedtfeld, Robert D. ;
Seyrig, Gregoire ;
Tiedje, James M. ;
Hashsham, Syed A. .
BIOMEDICAL MICRODEVICES, 2012, 14 (04) :769-778
[27]   A real-time LAMP-based dual-sample microfluidic chip for rapid and simultaneous detection of multiple waterborne pathogenic bacteria from coastal waters [J].
Jin, Jinglei ;
Duan, Lijun ;
Fu, Jiali ;
Chai, Fangchao ;
Zhou, Qianjin ;
Wang, Yaohua ;
Shao, Xinbin ;
Wang, Lei ;
Yan, Maocang ;
Su, Xiurong ;
Zhang, Yanjun ;
Pan, Junhang ;
Chen, Jiong .
ANALYTICAL METHODS, 2021, 13 (24) :2710-2721
[28]   Applicability of the "Real-Time PCR-Based Ready-to-Use Multi-Target Analytical System for GMO Detection" in processed maize matrices [J].
Kluga, Linda ;
Folloni, Silvia ;
Van den Bulcke, Marc ;
Van den Eede, Guy ;
Querci, Maddalena .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2012, 234 (01) :109-118
[29]   Applicability of the “Real-Time PCR-Based Ready-to-Use Multi-Target Analytical System for GMO Detection” in processed maize matrices [J].
Linda Kluga ;
Silvia Folloni ;
Marc Van den Bulcke ;
Guy Van den Eede ;
Maddalena Querci .
European Food Research and Technology, 2012, 234 :109-118
[30]   Four-channel asymmetric Real-Time PCR hybridization probe assay: A rapid pre-screening method for critical BCR-ABL kinase domain mutations [J].
Martinez-Serra, Jordi ;
Gutierrez, Antonio ;
Marcus, Toni F. ;
Soverini, Simona ;
Carlos Amat, Juan ;
Navarro-Palou, Maria ;
Ros, Teresa ;
Bex, Teresa ;
Ballester, Carmen ;
Miquel Bauca, Josep ;
SanFelix, Sara ;
Novo, Andres ;
Vidal, Carmen ;
Santos, Carmen ;
Besalduch, Joan .
CLINICAL BIOCHEMISTRY, 2012, 45 (4-5) :345-351