Quantitative assay of hepatitis B surface antigen by using surface plasmon resonance biosensor

被引:0
|
作者
Sang Yoon Hwang
Chang Hoon Yoon
Jun Yeoung Jeon
Sung Chul Choi
Eun Kyu Lee
机构
[1] Hanyang University,Bioprocessing Research Laboratory, Department of Chemical Engineering
[2] Isu Chemicals,GE Team
[3] Inc.,undefined
[4] DI Biotech,undefined
[5] Ltd.,undefined
[6] GreenCross Vaccine Corp.,undefined
来源
Biotechnology and Bioprocess Engineering | 2005年 / 10卷
关键词
SPR; biosensor; HBsAg; binding assay;
D O I
暂无
中图分类号
学科分类号
摘要
We performed a basic experiment for the rapid, on-line, real-time measurement of hepatitis B surface antigen using a surface plasmon resonance biosensor. We immobilized anti-HBsAg (hepatitis B surface antigen) polyclonal antibody, as a ligand, to the dextran layer on a CM5 chip surface that had previously been activated byN-hydroxysuccinimide. A sample solution containing HBsAg was fed through a microfluidic channel, and the reflecting angle change due to the mass increase from the binding was detected. The binding characteristics between HBsAg and its polyclonal antibody followed the typical monolayer adsorption isotherm. When the entire immobilized antibody had interacted, no additional, non-specific binding occurred, suggesting the immunoreaction was very specific. The bound antigen per unit mass of the antibody was independent of the immobilized ligand density. No significant steric hindrance was observed at an immobilization density of approximately 17.6 ng/mm2. The relationship between the HBsAg concentration in the sample solution and the antigen bound to the ligand was linear up to ca. 40 μg/mL. This linearity was much higher than that of the ELISA method. It appeared the antigen-antibody binding increased as the immobilized ligand density increased. In summary, this study showed the potential of this SPR biosensor-based method as a rapid, simple and multi-sample on-line assay. Once properly validated, it may serve as a more efficient method for HBsAg quantification for replacing the ELISA.
引用
收藏
页码:309 / 314
页数:5
相关论文
共 50 条
  • [1] Quantitative assay of hepatitis B surface antigen by using surface plasmon resonance biosensor
    Hwang, SY
    Yoo, CH
    Jeon, JY
    Choi, SC
    Lee, EK
    BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2005, 10 (04) : 309 - 314
  • [2] Determination of hepatitis B surface antigen by surface plasmon resonance biosensor
    Chen, ZZ
    Wang, KM
    Yang, XH
    Huang, SS
    Huang, HM
    Li, D
    Wang, Q
    ACTA CHIMICA SINICA, 2003, 61 (01) : 137 - 140
  • [3] Characterization of recombinant hepatitis B surface antigen using surface plasmon resonance
    Tung, JS
    Gimenez, J
    Przysiecki, CT
    Mark, G
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1998, 87 (01) : 76 - 80
  • [4] Quantitative measurement of serum hepatitis B surface antigen using an immunoradiometric assay in chronic hepatitis B
    Kwon H.-W.
    Lee H.-Y.
    Kim S.G.
    Kim W.
    Jung Y.J.
    Kang K.W.
    Chung J.-K.
    Lee M.C.
    Lee D.S.
    Nuclear Medicine and Molecular Imaging, 2011, 45 (1) : 15 - 20
  • [5] Multicenter Evaluation of the Elecsys Hepatitis B Surface Antigen Quantitative Assay
    Zacher, B. J.
    Moriconi, F.
    Bowden, S.
    Hammond, R.
    Louisirirotchanakul, S.
    Phisalprapa, P.
    Tanwandee, T.
    Wursthorn, K.
    Brunetto, M. R.
    Wedemeyer, H.
    Bonino, F.
    CLINICAL AND VACCINE IMMUNOLOGY, 2011, 18 (11) : 1943 - 1950
  • [6] Efficient Antifouling Surface for Quantitative Surface Plasmon Resonance Based Biosensor Analysis
    Nogues, Claude
    Leh, Herve
    Lautru, Joseph
    Delelis, Olivier
    Buckle, Malcolm
    PLOS ONE, 2012, 7 (09):
  • [7] A rapid biosensor chip assay for measuring of telomerase activity using surface plasmon resonance
    Maesawa, C
    Inaba, T
    Sato, H
    Iijima, S
    Ishida, K
    Terashima, M
    Sato, R
    Suzuki, M
    Yashima, A
    Ogasawara, S
    Oikawa, H
    Sato, N
    Saito, K
    Masuda, T
    NUCLEIC ACIDS RESEARCH, 2003, 31 (02)
  • [8] Surface plasmon resonance biosensor using heterodyne interferometry
    Joe, SF
    Wu, CM
    Chang, LB
    Hsieh, LZ
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS II PT 1AND 2, 2004, 5634 : 166 - 173
  • [9] Wide dynamic range of surface-plasmon-resonance-based assay for hepatitis B surface antigen antibody optimal detection in comparison with ELISA
    Tam, Yew Joon
    Zeenathul, Nazariah Allaudin
    Rezaei, Morvarid Akhavan
    Mustafa, Nor Hidayah
    Azmi, Mohd Lila Mohd
    Bahaman, Abdul Rani
    Lo, Sewn Cen
    Tan, Joo Shun
    Hani, Homayoun
    Rasedee, Abdullah
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2017, 64 (05) : 735 - 744
  • [10] A quantitative Hepatitis B surface antigen assay on Architect i2000.