Experimental two-phase flow measurement using ultra fast limited-angle-type electron beam X-ray computed tomography

被引:0
作者
M. Bieberle
F. Fischer
E. Schleicher
D. Koch
H.-J. Menz
H.-G. Mayer
U. Hampel
机构
[1] Forschungszentrum Dresden-Rossendorf e. V.,Institute of Safety Research
[2] Stuttgart University,Institute of Nuclear Energy Technology and Energy Systems
来源
Experiments in Fluids | 2009年 / 47卷
关键词
Flow Loop; Bubble Size Distribution; Algebraic Reconstruction Technique; Electron Beam Tomography; Radon Space;
D O I
暂无
中图分类号
学科分类号
摘要
An experimental evaluation of a novel limited-angle-type ultra fast electron beam X-ray computed tomography approach for the visualization and measurement of a gas–liquid two-phase flow is reported here. With this method, a simple linear electron beam scan is used to produce instantaneous radiographic views of a two-phase flow in a pipe segment of a flow loop. Electron beam scanning can be performed very rapidly, thus a frame rate of 5 kHz is achieved. Radiographic projections are recorded by a very fast detector arc made of zink–cadmium–telluride elements. This detector records the X-ray radiation passing through the object with a sampling rate of 1 MHz. The reconstruction of slice images from the recorded detector data is a limited-angle problem since in our scanning geometry the object’s Radon space is only incompletely sampled. It was investigated here, whether this technology is able to produce accurate gas fraction data from bubbly two-phase flow. Experiments were performed both on a Perspex phantom with known geometry and an experimental flow loop operated under vacuum conditions in an electron beam processing box.
引用
收藏
相关论文
共 62 条
  • [1] Barrett HH(1990)Limited-angle tomography for the nineties J Nucl Med 31 168-169
  • [2] Bieberle M(2006)Evaluation of a limited angle scanned electron beam X-ray approach for two-phase pipe flows Meas Sci Technol 17 2057-2065
  • [3] Hampel U(2007)Ultra fast limited-angle type X-ray tomography Appl Phys Lett 91 123516-307
  • [4] Bieberle M(1983)Cardiac computed tomography Proc IEEE 71 298-2251
  • [5] Fischer F(2007)Capacitance wire-mesh sensor for fast measurement of phase fraction distributions Meas Sci Technol 18 2245-481
  • [6] Schleicher E(1970)Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and X-ray photography J Theor Biol 29 471-72
  • [7] Koch D(2005)Ultrafast X-ray computed tomography with a linearly scanned electron beam source Flow Meas Instrum 16 65-165
  • [8] do Couto Aktay KS(2000)Development of an ultra fast X-ray computed tomography scanner system: application for measurement of instantaneous void distribution of gas–liquid two-phase flow Heat Trans Asian Res 29 155-307
  • [9] Menz H-J(1996)A dual sensor flow imaging tomographic system Meas Sci Technol 7 297-290
  • [10] Mayer H-G(2007)Experimental investigation on bubble turbulent diffusion in a vertical large-diameter pipe by wire-mesh sensors and correlation techniques Nucl Technol 158 275-912