Proof of live birth using postmortem multislice computed tomography (pmMSCT) in cases of suspected neonaticide: advantages of diagnostic imaging compared to conventional autopsy

被引:0
作者
Saskia S. Guddat
René Gapert
Michael Tsokos
Lars Oesterhelweg
机构
[1] Charité-University Medicine Berlin,Institute of Legal Medicine and Forensic Sciences
[2] University College Dublin,Human Anatomy Laboratory, UCD School of Medicine and Medical Science
来源
Forensic Science, Medicine, and Pathology | 2013年 / 9卷
关键词
Pulmonary and gastrointestinal aeration; Flotation test; Virtual autopsy; Forensic death investigation; Biological imaging;
D O I
暂无
中图分类号
学科分类号
摘要
Proof of live birth is of major importance in suspected neonaticide cases. Although not without controversy the lung flotation test is the main method used to asses this in different jurisdictions worldwide. The present study examines the usefulness of postmortem multislice computed tomography (pmMSCT) in the detection of live birth signs. Body scans were conducted on four infants, one was stillborn, another died a day after birth and the other two were classified as neonaticides. The appearance of the lungs, gastrointestinal tract and vascular system of the liver was compared in these cases. Clear differences were discernable between the lungs of the stillborn and the 1 day old infant. The aerated lungs and air in the stomach and duodenum were clearly visible in the latter case while the stillborn infant lacked these signs. The two neonaticide cases demonstrated similarly aerated lung tissue to the 1 day old infant. The hepatic vessels did not show any putrefactive gas changes in any of the cases. The extent of aeration of the peripheral alveoli was easily observable on the pmMSCT, thus making it a useful tool in the possible differentiation between artificially and naturally aerated lungs. During the four autopsies the classic flotation tests were performed and similar positive aeration of the lungs in the two neonaticides was shown. The stillborn’s tests, on the other hand were negative for aeration. The results of this study clearly demonstrate the advantages of using pmMSCT before commencing a conventional autopsy in cases of suspected neonaticide.
引用
收藏
页码:3 / 12
页数:9
相关论文
共 39 条
[1]  
Kellet RJ(1992)Infanticide and child destruction—the historical, legal and pathological aspects Forensic Sci Int 53 1-28
[2]  
Rosset A(2004)OsiriX: an open-source software for navigating in multidimensional DICOM images J Digit Imaging 17 205-216
[3]  
Spadola L(2003)Virtopsy, a new imaging horizon in forensic pathology: virtual autopsy by post-mortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI)—a feasibility study J Forensic Sci 48 386-403
[4]  
Ratib O(2006)VIRTOPSY: minimally invasive, imaging-guided virtual autopsy Radigraphics. 26 1305-1333
[5]  
Thali MJ(2012)Postmortem CT investigation of skeletal and dental maturation of the foetuses and newborn infants: a serial case study Forensic Sci Med Pathol 7 317-321
[6]  
Yen K(2012)Post-mortem computed tomography and 3D imaging: anthropological applications for juvenile remains Forensic Sci Med Pathol undefined undefined-undefined
[7]  
Schweitzer W(2011)Abandonment of newborn infants: a Danish forensic medical survey 1997–2008 Forensic Sci Med Pathol undefined undefined-undefined
[8]  
Vock P(undefined)undefined undefined undefined undefined-undefined
[9]  
Boesch C(undefined)undefined undefined undefined undefined-undefined
[10]  
Ozdoba C(undefined)undefined undefined undefined undefined-undefined