Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectral prediction of postmortem interval from vitreous humor samples

被引:0
作者
Ji Zhang
Xin Wei
Jiao Huang
Hancheng Lin
Kaifei Deng
Zhengdong Li
Yu Shao
Donghua Zou
Yijiu Chen
Ping Huang
Zhenyuan Wang
机构
[1] Ministry of Justice,Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science
[2] Xi’an Jiaotong University,Department of Forensic Pathology
[3] Xuzhou Medical University,Department of Forensic Medicine
来源
Analytical and Bioanalytical Chemistry | 2018年 / 410卷
关键词
Forensic medicine; Postmortem interval; Fourier transform infrared spectroscopy; Machine learning; Vitreous humor;
D O I
暂无
中图分类号
学科分类号
摘要
Evaluation of postmortem interval (PMI) is of paramount importance to guide criminal investigations, especially when witnesses are not found. However, accurate PMI estimation is a challenging task in the forensic community due to the limitations of existing methods. The study aims to investigate the potential of attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy for predicting PMI based on vitreous humor (VH). VH samples were collected from 72 rabbits in the range of 0–48 h postmortem at a 6-h interval. Their FTIR spectra were normalized by the extended multiplicative signal correction (RMSC) and divided into calibration and validation sets. After analysis of the absorption bands, the Bayesian ridge regression (BRR), support vector regression (SVR), and artificial neural network (ANN) methods were established by the calibration set using a 10-fold cross-validation that was further used to predict the PMI in the validation set. The validity of the models was assessed by a permutation test. The current study demonstrated that multiple macromolecules in the VH samples were reflected in a FTIR spectrum, and the spectral absorption bands at 1313 and 925 cm−1 were highly correlated with PMI. The three models allowed generalization to the validation set due to similar R2 and errors between the calibration and validation tests. The highest accuracy with R2 = 0.983 and error = 2.018 h was achieved by the ANN model in the validation test. The results suggest that ATR-FTIR spectroscopy may be useful for VH analysis in order to predict PMI in the future.
引用
收藏
页码:7611 / 7620
页数:9
相关论文
共 261 条
  • [1] Mathur A(2011)An overview of methods used for estimation of time since death Aust J Forensic Sci 43 275-285
  • [2] Agrawal YK(1991)A new biochemical method for estimation of postmortem time Forensic Sci Int 51 139-146
  • [3] Rognum TO(2014)Chemometric estimation of post-mortem interval based on Na Aust J Forensic Sci 46 166-179
  • [4] Hauge S(1997) and K Am J Forensic Med Pathol 18 158-162
  • [5] Oyasaeter S(2016) concentrations from human vitreous humour by linear least squares and artificial neural networks modelling Forensic Sci Int 262 160-165
  • [6] Saugstad OD(2018)Determination of postmortem interval by sampling vitreous humour Trends Mol Med 24 197-205
  • [7] Gadzuric SB(2018)Estimation of time since death by vitreous humor hypoxanthine, potassium, and ambient temperature Talanta 186 489-496
  • [8] Kuzmanovic SOP(2015)Using metabolomics to investigate biomarkers of drug addiction Anal Bioanal Chem 407 3659-3665
  • [9] Jokic AI(2016)Simultaneous detection of multiple inherited metabolic diseases using GC-MS urinary metabolomics by chemometrics multi-class classification strategies Anal Bioanal Chem 408 3103-3112
  • [10] Vranes MB(2015)A preliminary study on postmortem interval estimation of suffocated rats by GC-MS/MS-based plasma metabolic profiling J Forensic Sci 60 759-763