Assessment of indoor air quality and their inter-association in hospitals of northern India—a cross-sectional study

被引:0
|
作者
Anam Taushiba
Samridhi Dwivedi
Farheen Zehra
Pashupati Nath Shukla
Alfred J. Lawrence
机构
[1] Isabella Thoburn College,Department of Chemistry
[2] Integral University,Department of Environmental Science
[3] National Botanical Research Institute,Department of Pharmacology & Microbial Technology
来源
Air Quality, Atmosphere & Health | 2023年 / 16卷
关键词
Indoor air quality; Nosocomial infection; Exposure; Mold; Bacteria; Indoor pollution;
D O I
暂无
中图分类号
学科分类号
摘要
This study was commenced to evaluate the indoor and outdoor air quality concentrations of PM2.5, sub-micron particles (PM>2.5, PM1.0–2.5, PM0.50 –1.0, PM0.25–0.50, and PM<0.25), heavy metals, and microbial contaminants along with their identification in three different hospitals of Lucknow City. The study was conducted from February 2022 to April 2022 in hospitals situated in the commercial, residential, and industrial belts of the city. The indoor concentration trend of particulate matter as observed during the study suggested that most of the highest concentrations belonged to the hospital situated in an industrial area. The highest obtained indoor and outdoor concentrations for PM1.0–2.5, PM0.50–1.0, PM0.25–0.50, and PM<0.25 are 40.44 µg/m3, 56.08 µg/m3, 67.20 µg/m3, 74.50 µg/m3, 61.9 µg/m3, 79.3 µg/m3, 82.0 µg/m3, and 93.9 µg/m3, respectively, which belonged to hospital C situated in the industrial belt. However, for PM>2.5, the highest indoor concentration obtained belonged to hospital B, i.e., 30.7 µg/m3, which is situated in the residential belt of the city. Regarding PM2.5, the highest indoor and outdoor concentrations obtained are 149.41 µg/m3 and 227.45 µg/m3, which were recorded at hospital A and hospital C, respectively. The present study also observed that a high bacterial load of 1389.21 CFU/m3 is recorded in hospital B, and the fungi load was highest in hospital C with 786.34 CFU/m3. Henceforth, the present study offers thorough information on the various air pollutants in a crucial indoor setting, which will further aid the researchers in the field to identify and mitigate the same more precisely.
引用
收藏
页码:1023 / 1036
页数:13
相关论文
共 50 条
  • [1] Assessment of indoor air quality and their inter-association in hospitals of northern India-a cross-sectional study
    Taushiba, Anam
    Dwivedi, Samridhi
    Zehra, Farheen
    Shukla, Pashupati Nath
    Lawrence, Alfred J.
    AIR QUALITY ATMOSPHERE AND HEALTH, 2023, 16 (05) : 1023 - 1036
  • [2] Association of early menopause with indoor air pollution: A multilevel modelling analysis of the nationally representative cross-sectional study in India
    Halder, Pritam
    Soni, Anamika
    Seth, Ashwani
    Vijayakumar, Dheenadahayalan
    Das, Anamika
    Sankhyan, Sujata
    Mamgai, Anshul
    Pal, Saumyarup
    Tiwari, Jaya
    Baranwal, Aparna
    Chaitra, C. M.
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2025, 14 (01) : 173 - 183
  • [3] Community knowledge, attitude and behaviour towards indoor air quality: A national cross-sectional study in Singapore
    Unni, Bindhu
    Tang, Nicholas
    Cheng, Ying Ming
    Gan, Damian
    Aik, Joel
    ENVIRONMENTAL SCIENCE & POLICY, 2022, 136 : 348 - 356
  • [4] Indoor microbiome, air pollutants and asthma, rhinitis and eczema in preschool children - A repeated cross-sectional study
    Sun, Yu
    Meng, Yi
    Ou, Zheyuan
    Li, Yanling
    Zhang, Mei
    Chen, Yang
    Zhang, Zefei
    Chen, Xingyi
    Mu, Peiqiang
    Norback, Dan
    Zhao, Zhuohui
    Zhang, Xin
    Fu, Xi
    ENVIRONMENT INTERNATIONAL, 2022, 161
  • [5] Assessment of indoor air quality and characterization of indoor settled dust in schools of Tezpur, Northeast India
    Nath, Anamika
    Saikia, Dimpi
    Nonglait, Mebaaibok L.
    Deka, Pratibha
    AIR QUALITY ATMOSPHERE AND HEALTH, 2024, : 793 - 814
  • [6] Assessment of Indoor Particulate Matter and Teacher's Perceived Indoor Climate in Government Schools of Bilaspur District, Chhattisgarh, India: A Cross-Sectional Study
    Pritwani, Sabhya
    Devasenapathy, Niveditha
    INDIAN JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2024, 28 (02) : 120 - 126
  • [7] The relationship between occupant behaviour and indoor air quality in Malaysian hospital outpatient departments: A multistage cross-sectional study
    Ibrahim, Farha
    Samsudin, Ely Zarina
    Ishak, Ahmad Razali
    Sathasivam, Jeyanthini
    HELIYON, 2024, 10 (14)
  • [8] Indoor air pollution affects hypertension risk in rural women in Northern China by interfering with the uptake of metal elements: A preliminary cross-sectional study
    Wang, Bin
    Zhu, Yibing
    Pang, Yiming
    Xie, Jing
    Hao, Yongxiu
    Yan, Huina
    Li, Zhiwen
    Ye, Rongwei
    ENVIRONMENTAL POLLUTION, 2018, 240 : 267 - 272
  • [9] Indoor air quality assessment in a school buildling in Chennai City, India
    Nagendra, S. M. Shiva
    Harika, P. Sri
    AIR POLLUTION XVIII, 2010, 136 : 275 - 286
  • [10] A cross-sectional study on aetiology of diarrhoeal disease, India
    Purwar, S.
    Bhattacharya, D.
    Metgud, S. C.
    Kumar, D.
    Chitambar, S. D.
    Roy, S.
    INDIAN JOURNAL OF MEDICAL MICROBIOLOGY, 2016, 34 (03) : 375 - 379