Information is lacking on the nonlinear dynamic response of r.c. base-isolated buildings where asymmetries are due to fire-induced lateral stiffness eccentricities in the frame members of the superstructure or in the base-isolation system. To study the seismic response following fire, a numerical investigation is carried out on four-, six- and eight-storey r.c. base-isolated structures composed of a basement and three, five and seven storeys above ground level, respectively. The base-isolation system is constituted of High-Damping-Laminated-Rubber Bearings, inserted on the top of the columns of the basement. Different values of the isolation ratio, defined as the ratio between the fundamental vibration period of the base-isolated and fixed-base structures above the isolation system, and plan-aspect ratio, defined as the ratio between the plan dimensions of the building, are considered. Fire scenarios correspond to the fire compartment confined to the whole (i.e. symmetric case) and half (i.e. asymmetric case) area of the base-isolation level (i.e. basement, F0) and superstructure (i.e. first level, F1) at 30 and 60 min of fire resistance, respectively. A thermal–mechanical mapping analysis is carried out, with reduced mechanical properties of r.c. cross-sections, in line with the 500 °C isotherm method proposed by Eurocode 2, and HDLRBs, in accordance with a proposed 200 °C isotherm method. Finally, the nonlinear dynamic analysis is carried out with reference to near-fault earthquakes selected and scaled on the design hypotheses adopted for the test structures.
引用
收藏
页码:3673 / 3694
页数:21
相关论文
共 56 条
[1]  
Anagnostopoulos SA(2015)Earthquake induced torsion in buildings: critical review and state of the art Earthq Struct 8 305-377
[2]  
Kyrkos MT(2013)Performance of reinforced concrete structures subjected to fire following earthquake Eur J Environ Civ Eng 17 270-292
[3]  
Stathopoulos KG(1979)High temperature vulcanization of elastomers Rubber Chem Technol 52 725-734
[4]  
Behnam B(2009)Design ground motions near active faults Bull NZ Soc Earthq Eng 42 1-8
[5]  
Ronagh H(2010)Near-source seismic demand and pulse-like records: a discussion for L’Aquila earthquake Earthq Eng Struct Dyn 39 1039-1062
[6]  
Bhowmick AK(1994)Nonlinear response of torsionally coupled base isolated structure ASCE J Struct Eng 120 1-22
[7]  
Mukhopadhyah R(2009)Effects of heating on the behavior of lead–rubber bearings. I: theory J Struct Eng 135 1440-1449
[8]  
De SK(2009)Seismic behaviour of asymmetric base isolated structures with various distributions of isolators Eng Struct 31 910-921
[9]  
Bray JD(2013)Simplified approach for evaluating residual strength of fire-exposed reinforced concrete columns Mater Struct 46 2059-2075
[10]  
Rodriguez-Marek A(2016)Further results on the heating of single and multi-core lead–rubber bearings and dampers Bull Earthq Eng 14 999-1016