Randomised study for the 1-year crestal bone maintenance around modified diameter implants with different loading protocols: a radiographic evaluation

被引:0
作者
Matteo Danza
Pietro Tortora
Alessandro Quaranta
Vittoria Perrotti
Iole Vozza
Adriano Piattelli
机构
[1] University of Rome,Dental School “Sapienza”
[2] University of Chieti-Pescara,Dental School
来源
Clinical Oral Investigations | 2010年 / 14卷
关键词
Bone maintenance; Diagnostic imaging; Dental implants; Radiograph; Randomised study; Loading protocols;
D O I
暂无
中图分类号
学科分类号
摘要
This study evaluated by standardised digitised periapical radiography the crestal bone maintenance around modified diameter internal hex implants with variable thread design and narrow neck loaded with different procedures. Forty implants were placed in 25 patients. Twenty implants were conventionally loaded, 20 ones immediately loaded. Radiographs were taken with a customised bite record and processed with software. Measurements of bone from the fixture–abutment junction to mesial and distal marginal bone levels were made. Student’s t test statistical analysis was adopted. Baseline data were variable; at 1-year follow-up, there were no significant differences for marginal bone loss between immediately and conventionally loaded maxillary implants (p = 0.1031), whilst there were slight significant differences between immediately and conventionally loaded implants in the mandible (p = 0.0141). Crestal bone maintenance around conventionally and immediately loaded modified diameter implants was similar, with slight significant differences in mandible where a lower marginal bone loss was observed.
引用
收藏
页码:417 / 426
页数:9
相关论文
共 166 条
  • [1] Szmukler-Moncler S(2000)Considerations preliminary to the application of early and immediate loading protocols in dental implantology Clin Oral Implants Res 11 12-25
  • [2] Piattelli A(2005)Immediate and early implant loading protocols: a literature review of clinical studies J Prosthet Dent 94 242-258
  • [3] Favero GA(2005)Immediate occlusal loading of double acid-etched surface titanium implants in 41 consecutive full-arch cases in the mandible and maxilla: 6- to 74-month results J Periodontol 76 1972-1981
  • [4] Dubruille JH(1996)Immediate loading of titanium plasma-sprayed implants: an histologic analysis in monkeys J Periodontol 69 321-327
  • [5] Attard NJ(2002)Peri-implant bone reactions to immediately loaded implants. An experimental study in monkeys J Periodontol 72 506-511
  • [6] Zarb GA(2005)Immediate versus delayed loading of dental implants in the maxillae of minipigs. Part II: histomorphometric analysis Int J Oral Maxillofac Implants 20 540-546
  • [7] Ibañez JC(2007)Impact of implant overloading on the peri-implant bone in inflamed and non-inflamed peri-implant mucosa Clin Oral Implants Res 18 601-610
  • [8] Tahhan MJ(2001)The significance of passive framework fit in implant prosthodontics: current status Implant Dent 10 892-895
  • [9] Zamar JA(2001)Immediate occlusal loading of Brånemark implants applied in various jawbone regions: a prospective, 1-year clinical study Clin Implant Dent Relat Res 3 204-213
  • [10] Menendez AB(2003)Immediate functional loading of Brånemark System implants with enhanced initial stability: a prospective 1- to 2-year clinical and radiographic study Clin Implant Dent Relat Res 5 10-20