Extension of Rapid Phase-Contrast Magnetic Resonance Imaging Using BRISK in Multidirectional Flow

被引:0
作者
Bradley L. Hershey
Mark Doyle
Eduardo Kortright
Rohan More
Geetha Rayarao
Andreas Anayiotos
机构
[1] University of Alabama at Birmingham,Department of Biomedical Engineering
[2] Allegheny Singer Research Institute,Department of Computer Science
[3] University of New Orleans,undefined
来源
Annals of Biomedical Engineering | 2005年 / 33卷
关键词
Rapid MRI imaging; Computational simulations; Hemodynamics;
D O I
暂无
中图分类号
学科分类号
摘要
We developed BRISK–CON–VPS, a rapid phase-contrast cine approach that is a hybrid of the BRISK–VPS (Block Regional Interpolation Scheme for k-space) and conventional (CONV–VPS) scanning employing k-space views per segment (VPS). BRISK–CON–VPS allows data acquisition approximately four times faster than CONV–VPS imaging and has the advantage compared to BRISK–VPS that it can potentially be incorporated into real-time applications. In BRISK–CON–VPS contiguous regions of k-space are sampled using a views per segment factor that is varied as a function of distance from the k-space center. Computational fluid dynamics (CFD) data were used to simulate CONV–VPS, BRISK–VPS, and BRISK–CON–VPS. BRISK–CON–VPS was simulated by incrementing the VPS progressively with increasing distance from the k-space origin while BRISK–VPS was simulated using a uniform VPS applied to the sparse sampling scheme. Simulations showed that up to a base VPS of 5, both BRISK–CON–VPS and BRISK–VPS retained excellent axial-velocity accuracy. Secondary in-plane velocity flow fields were well represented with BRISK–CON–VPS and BRISK–VPS up to a base VPS of 3. CONV–VPS, BRISK–CON–VPS, and BRISK–VPS were applied in vivo and shown to provide comparable quantitative flow data. BRISK–CON–VPS accomplishes breath-hold acquisitions as efficiently as BRISK–VPS, but without requiring data interpolation or under-sampling k-space.
引用
收藏
页码:929 / 936
页数:7
相关论文
共 50 条
  • [21] Quantifying Hemodynamic Changes in Moyamoya Disease Based on Two-Dimensional Cine Phase-Contrast Magnetic Resonance Imaging and Computational Fluid Dynamics
    Sun, Wenbo
    Ruan, Zhao
    Dai, Xuan
    Li, Sirui
    Li, Shuo
    Zhang, Jianjian
    Chen, Jincao
    Zhang, Heye
    Xu, Haibo
    WORLD NEUROSURGERY, 2018, 120 : E1301 - E1309
  • [22] A phase-contrast MRI study of physiologic cerebral venous flow
    Stoquart-ElSankari, Souraya
    Lehmann, Pierre
    Villette, Agnes
    Czosnyka, Marek
    Meyer, Marc-Etienne
    Deramond, Herve
    Baledent, Olivier
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2009, 29 (06) : 1208 - 1215
  • [23] Blood flow of the venous system during resuscitative endovascular balloon occlusion of the aorta: Noninvasive evaluation using phase contrast magnetic resonance imaging
    Izawa, Yoshimitsu
    Hishikawa, Shuji
    Matsumura, Yosuke
    Nakamura, Hiroyasu
    Sugimoto, Hideharu
    Mato, Takashi
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2020, 88 (02) : 305 - 309
  • [24] Influence of Respiration on Collateral Flow in the Fontan Population Using Real-time Phase-contrast Cardiovascular Magnetic Resonance Collateral Flow Does Not Protect the Ventricle From Volume Deficiency and Diastolic Dysfunction
    Blessing, Maja
    Koerperich, Hermann
    Barth, Peter
    Michel, Miriam
    Dubowy, Otto
    Forreiter, Sophia
    Laser, Kai Thorsten
    JOURNAL OF THORACIC IMAGING, 2023, 38 (05) : W64 - W74
  • [25] Before and after Endovascular Aortic Repair in the Same Patients with Aortic Dissection: A Cohort Study of Four-Dimensional Phase-Contrast Magnetic Resonance Imaging
    Chen, Chien-Wei
    Fang, Yueh-Fu
    Tseng, Yuan-Hsi
    Wong, Min Yi
    Lin, Yu-Hui
    Hsu, Yin-Chen
    Lin, Bor-Shyh
    Huang, Yao-Kuang
    DIAGNOSTICS, 2021, 11 (10)
  • [26] Assessment of splanchnic blood flow using magnetic resonance imaging
    Barthelmes, Daniel
    Parviainen, Ilkka
    Vainio, Pauli
    Vanninen, Ritva
    Takala, Jukka
    Ikonen, Aki
    Tueller, David
    Jakob, Stephan M.
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2009, 21 (06) : 693 - 700
  • [27] Cardiothoracic Magnetic Resonance Flow Imaging
    Hope, Michael D.
    Sedlic, Tony
    Dyverfeldt, Petter
    JOURNAL OF THORACIC IMAGING, 2013, 28 (04) : 217 - 230
  • [28] Visualization and quantification of flow and velocity fields in intracranial arteriovenous malformations using phase-contrast MR angiography
    Grinstead, JW
    Sinha, S
    Tateshima, S
    Nien, YL
    Vinuela, F
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (02) : 553 - 555
  • [29] Computational Simulations and Experimental Studies of 3D Phase-Contrast Imaging of Fluid Flow in Carotid Bifurcation Geometries
    Marshall, Ian
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (04) : 928 - 934
  • [30] Venous Segmental Flow Changes after Superficial Venous Intervention Demonstrating by Quantitative Phase-Contrast Magnetic Resonance Analysis: Preliminary Data from a Longitudinal Cohort Study
    Chen, Chien-Wei
    Tseng, Yuan-Hsi
    Kao, Chih-Chen
    Ngo, Yeh Giin
    Lee, Chung-Yuan
    Yang, Teng-Yao
    Lin, Yu-Hui
    Huang, Yao-Kuang
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (06):