Monitoring of Regional Lung Ventilation Using Electrical Impedance Tomography After Cardiac Surgery in Infants and Children

被引:0
|
作者
Ulrich Krause
Kristin Becker
Günter Hahn
Jörg Dittmar
Wolfgang Ruschewski
Thomas Paul
机构
[1] Georg-August-University Göttingen,Department of Pediatric Cardiology and Intensive Care Medicine, University Medical Center Göttingen
[2] University Medical Center Göttingen,Department of Anesthesiology, Emergency and Intensive Care Medicine
[3] University Medical Center Göttingen,Department of Thoracic and Cardiovascular Surgery, Congenital Cardiac Surgery
来源
Pediatric Cardiology | 2014年 / 35卷
关键词
Congenital heart disease; Electrical impedance tomography; Regional lung ventilation; Intensive care;
D O I
暂无
中图分类号
学科分类号
摘要
Electrical impedance tomography (EIT) is a noninvasive method to monitor regional lung ventilation in infants and children without using radiation. The objective of this prospective study was to determine the value of EIT as an additional monitoring tool to assess regional lung ventilation after pediatric cardiac surgery for congenital heart disease in infants and children. EIT monitoring was performed in a prospective study comprising 30 pediatric patients who were mechanically ventilated after cardiac surgery. Data were analyzed off-line with respect to regional lung ventilation in different clinical situations. EIT data were correlated with respirator settings and arterial carbon dioxide (CO2) partial pressure in the blood. In 29 of 30 patients, regional ventilation of the lung could sufficiently and reliably be monitored by means of EIT. The effects of the transition from mechanical ventilation to spontaneous breathing after extubation on regional lung ventilation were studied. After extubation, a significant decrease of relative impedance changes was evident. In addition, a negative correlation of arterial CO2 partial pressure and relative impedance changes could be shown. EIT was sufficient to discriminate differences of regional lung ventilation in children and adolescents after cardiac surgery. EIT reliably provided additional information on regional lung ventilation in children after cardiac surgery. Neither chest tubes nor pacemaker wires nor the intensive care unit environment interfered with the application of EIT. EIT therefore may be used as an additional real-time monitoring tool in pediatric cardiac intensive care because it is noninvasive.
引用
收藏
页码:990 / 997
页数:7
相关论文
共 50 条
  • [21] Electrical impedance tomography - a method for monitoring regional lung function
    Frerichs, I
    TECHNISCHES MESSEN, 2004, 71 (09): : 519 - 526
  • [22] Regional Ventilation-Perfusion Matching by Electrical Impedance Tomography After Single Lung Transplant
    Scaravilli, Vittorio
    Colombo, Sebastiano Maria
    Fumagalli, Jacopo
    Mauri, Tommaso
    Zanella, Alberto
    Rosso, Lorenzo
    Grasselli, Giacomo
    ASAIO JOURNAL, 2024, 70 (03) : e49 - e52
  • [23] Lung Ventilation Monitoring Incorporating Prior Information by Electrical Impedance Tomography
    Chen, Xiaoyan
    Wang, Huanxiang
    Shi, Xiaolei
    Yan, Yong
    Cui, Ziqiang
    2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, : 1531 - +
  • [24] Respiratory Support Effects over Time on Regional Lung Ventilation Assessed by Electrical Impedance Tomography in Premature Infants
    Virsilas, Ernestas
    Valiulis, Arunas
    Kubilius, Raimondas
    Peciuliene, Skaiste
    Liubsys, Arunas
    MEDICINA-LITHUANIA, 2024, 60 (03):
  • [25] SIMPLIFIED ELECTRICAL IMPEDANCE TOMOGRAPHY FOR MONITORING VENTILATION IN CRITICALLY ILL CHILDREN
    Pung, Jordan
    Miller, Andrew
    Rotta, Alexandre
    CRITICAL CARE MEDICINE, 2023, 51 (01) : 344 - 344
  • [26] Individualized Multiplanar Electrical Impedance Tomography in Infants to Optimize Lung Monitoring
    Miedema, Martijn
    Waldmann, Andreas
    McCall, Karen E.
    Bohm, Stephan H.
    van Kaam, Anton H.
    Tingay, David G.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195 (04) : 536 - 538
  • [27] Methodology of electrical impedance tomography-derived measures of regional lung ventilation
    Frerichs, Inez
    Becher, Tobias
    Weiler, Norbert
    CRITICAL CARE, 2014, 18 (06):
  • [28] Methodology of electrical impedance tomography-derived measures of regional lung ventilation
    Inéz Frerichs
    Tobias Becher
    Norbert Weiler
    Critical Care, 18
  • [29] Unilateral empyema impacts the assessment of regional lung ventilation by electrical impedance tomography
    Blaeser, D.
    Pulletz, S.
    Becher, T.
    Schaedler, D.
    Elke, G.
    Weiler, N.
    Frerichs, I.
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (06) : 975 - 983
  • [30] EFFECT OF UNILATERAL EMPYEMA ON THE ASSESSMENT OF REGIONAL LUNG VENTILATION BY ELECTRICAL IMPEDANCE TOMOGRAPHY
    Blaeser, D.
    Pulletz, S.
    Becher, T.
    Weiler, N.
    Frerichs, I.
    INTENSIVE CARE MEDICINE, 2013, 39 : S494 - S494