Detection of power swing and fault occurring simultaneously with power swing using instantaneous frequency

被引:0
作者
Behrooz Taheri
Sirus Salehimehr
Farzad Razavi
Mohammad Parpaei
机构
[1] Islamic Azad University,Young Researchers and Elite Club, Qazvin Branch
[2] Islamic Azad University,Faculty of Electrical, Biomedical and Mechatronics Engineering, Qazvin Branch
[3] Amirkabir University of Technology,Department of Electrical Engineering
来源
Energy Systems | 2020年 / 11卷
关键词
Power swing; Distance relay; Power system protection; Instantaneous frequency;
D O I
暂无
中图分类号
学科分类号
摘要
Energy transmission lines play a more important role in power transferring from producer to consumers. Energy transmission lines should be protected from the fault and the faults should be cleared as soon as possible time. Distance relays due to their simplicity application are widely used for protection of power transmission lines. When a power swing occurs in the power system the distance relay may mal-operate during this phenomenon. In order to prevent this, the power swing blocking function is used in distance relays. In this paper, a new method based on the rate of change of the instantaneous frequency is proposed. This method has been tested practically in a standard two-area network and its applicability for detection of different types of faults is presented. One of the features of this method is low computing and simplicity in implementation, independent of network type, unnecessarily complicated setting, high impedance fault detection, and unstable power swing detection. Also, the proposed method is compared with the conventional industrial method and it has been shown that the proposed method has better performance.
引用
收藏
页码:491 / 514
页数:23
相关论文
共 73 条
  • [1] Silva KM(2010)Distance protection using a wavelet-based filtering algorithm Electr. Power Syst. Res. 80 84-90
  • [2] Neves WL(2017)Performance evaluation of distance protection of transmission lines connected with VSC-HVDC system using closed-loop test in RTDS Electr. Power Syst. Res. 152 168-183
  • [3] Souza BA(2008)A distance protection relay for a 1000-kV UHV transmission line IEEE Trans. Power Deliv. 23 1795-1804
  • [4] Alam MM(2008)A novel scheme to identify symmetrical faults occurring during power swings IEEE Trans. Power Deliv. 23 73-78
  • [5] Leite H(2007)Distance relay with out-of-step blocking function using wavelet transform IEEE Trans. Power Deliv. 22 1360-1366
  • [6] Silva N(2010)Fast distance relay scheme for detecting symmetrical fault during power swing IEEE Trans. Power Deliv. 25 2205-2212
  • [7] da Silva Carvalho A(2010)Detection of symmetrical faults by distance relays during power swings IEEE Trans. Power Deliv. 25 81-87
  • [8] Xu Z(2010)Theoretical fundamentals and implementation of novel self-adaptive distance protection resistant to power swings IEEE Trans. Power Deliv. 25 1372-1383
  • [9] Huang S(2012)A classification approach using support vector machines to prevent distance relay maloperation under power swing and voltage instability IEEE Trans. Power Deliv. 27 1124-1133
  • [10] Ran L(2008)A novel power swing blocking scheme using adaptive neuro-fuzzy inference system Electr. Power Syst. Res. 78 1138-1146