Performance evaluation of a robot-assisted catheter operating system with haptic feedback

被引:0
作者
Yu Song
Shuxiang Guo
Xuanchun Yin
Linshuai Zhang
Hideyuki Hirata
Hidenori Ishihara
Takashi Tamiya
机构
[1] Kagawa University,Graduate School of Engineering
[2] Beijing Institute of Technology,Key Laboratory of Convergence Medical Engineering System and Healthcare Technology, the Ministry of Industry and Information Technology
[3] Kagawa University,Faculty of Engineering
[4] South China Agricultural University,College of Engineering
[5] Kagawa University,Department of Neurological Surgery Faculty of Medicine
来源
Biomedical Microdevices | 2018年 / 20卷
关键词
Robot-assisted catheter operating system (RCOS); Magnetorheological (MR) fluids; Haptic interface; Catheter manipulator; Haptic feedback;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interface, a hall sensor-based closed-loop control strategy is employed. In slave side, a catheter manipulator is presented to deliver the patient catheter, according to position commands received from the master haptic interface. The contact forces between the patient catheter and blood vessel system can be measured by designed force sensor unit of catheter manipulator. Four levels of haptic force are provided to make the operator aware of the resistance encountered by the patient catheter during the insertion procedure. The catheter manipulator was evaluated for precision positioning. The time lag from the sensed motion to replicated motion is tested. To verify the efficacy of the proposed haptic feedback method, the evaluation experiments in vitro are carried out. The results demonstrate that the proposed system has the ability to enable decreasing the contact forces between the catheter and vasculature.
引用
收藏
相关论文
共 145 条
  • [21] Volkova O(2010)Design and fabrication of a robotic mechanism for remote steering and positioning of interventional devices Int. J. Med. Rob. Comput. Assisted. Surg. 6 160-1600
  • [22] Carlson JD(2013)Robotic endovascular surgery Asian Cardiovasc. Thorac. Ann. 22 110-16
  • [23] Catanzarite DM(2009)Design and performance evaluation of a remote catheter navigation system IEEE Trans. Biomed. Eng. 56 1901-1054
  • [24] Clair KAS(1999)Fiber-optic tactile microsensor for detecting the position of the tip of a fiberscope J. Sel. Top. Quantum Electron. 5 115-undefined
  • [25] Cha HJ(2017)Design and evaluation of safety operation VR training system for robotic catheter surgery Med. Biol. Eng. Comput. 56 25-undefined
  • [26] Yi BJ(2013)Safety and feasibility of robotic percutaneous coronary intervention PRECISE (percutaneous robotically-enhanced coronary intervention) study J. Am. Coll. Cardiol. 61 1596-undefined
  • [27] Won JY(2016)Design and experimental evaluation of a teleoperated haptic robot assisted catheter operating system J. Intell. Mater. Syst. Struct. 27 3-undefined
  • [28] Fabrizio MD(2016)Safety operation consciousness realization of a MR fluids-based novel haptic Interface for teleoperated catheter minimally invasive neurosurgery IEEE/ASME Trans. Mechatron. 21 1043-undefined
  • [29] Lee BR(2018)Operating force information on-line acquisition of a novel slave manipulator for vascular interventional surgery Biomed. Microdevices 20 33-undefined
  • [30] Chan DY(undefined)undefined undefined undefined undefined-undefined