High-Sensitivity Gold-Coated Refractive Index Biosensor Based on Surface Plasmon Resonance

被引:0
作者
Hasan Abdullah
Muhammad Shahin Uddin
Bikash Kumar Paul
机构
[1] Mawlana Bhashani Science and Technology University,Department of Information and Communication Technology
[2] Daffodil International University,Department of Software Engineering, Daffodil Smart City
来源
Plasmonics | 2023年 / 18卷
关键词
PCF; SPR; Biosensor; Sensitivity response; Confinement loss;
D O I
暂无
中图分类号
学科分类号
摘要
High-sensitivity gold-coated photonic crystal fiber (PCF) refractive index (RI) biosensor based on surface plasmon resonance (SPR) is proposed. To evaluate the sensing characteristics of the proposed sensor, the finite element method (FEM) is used. As a base material, silica is used and as a plasmonic material, 40-nm thickness gold layer is chosen. Resonance of electrons requires active plasmonic material. Gold is chosen because it has the highest plasmonic activity of all active plasmonic materials and offers the best resonance. The uppermost wavelength sensitivity response of 45,409.14 nm/RIU is obtained at RI 1.35. The maximum amplitude resolution, amplitude sensitivity response, birefringence, transmittance, coupling length, and dispersion of 2.52 × 10−05, 7679.06 RIU−1, 3.1 × 10−4, − 24.5 dB, 1,87,500 µm, and − 7000 ps/(nm-km) are obtained respectively. The proposed sensor is a strong contender for detecting microfluidic analytes in the biosensor field for its exceptional sensitivity response, compact structural design, and tunable performance.
引用
收藏
页码:2213 / 2223
页数:10
相关论文
共 144 条
  • [1] Xu Y(2018)$\text{MoS}_2 $-based highly sensitive near-infrared surface plasmon resonance refractive index sensor IEEE J Sel Top Quantum Electron 25 1-7
  • [2] Wu L(2021)Cancer detection with surface plasmon resonance-based photonic crystal fiber biosensor Plasmonics 16 1605-1612
  • [3] Ang LK(2021)Surface plasmon resonance based highly sensitive gold coated PCF biosensor Appl Phys A 127 1-12
  • [4] Yasli A(2018)Ultrahigh sensitivity refractive index sensor of a D-shaped PCF based on surface plasmon resonance Appl Opt 57 4002-4007
  • [5] Islam MR(2022)A comprehensive study of large negative dispersion and highly nonlinear perforated core PCF: theoretical insight Phys Scr 97 40734-40747
  • [6] Iftekher ANM(2021)Surface plasmon resonance chemical sensor composed of a microstructured optical fiber for the detection of an ultra-wide refractive index range and gas-liquid pollutants Opt Express 29 1-14
  • [7] Hasan KR(2022)Antimonene-gold based twin-core SPR sensor with a side-polished semi-arc groove dual sensing channel: an investigation with 2D material Opt Quant Electron 54 76-84
  • [8] Nayen M(2020)A surface plasmon resonance bio-sensor based on dual core D-shaped photonic crystal fibre embedded with silver nanowires for multisensing IEEE Sens J 21 1021-1030
  • [9] Islam SB(2021)A highly birefringent bend-insensitive porous core PCF for endlessly single-mode operation in THz regime: an analysis with core porosity Appl Nanosci 11 8287-8293
  • [10] Islam R(2018)Haque E, Hossain MA, Ahmed F, Namihira Y (2018) Surface plasmon resonance sensor based on modified $ D $-shaped photonic crystal fiber for wider range of refractive index detection IEEE Sens J 18 1928-1131