Aortic valves stenosis and regurgitation: assessment with dual source computed tomography

被引:0
作者
Xiaofei Li
Lijun Tang
Lei Zhou
Yuqing Duan
Sheng Yanhui
Rong Yang
Yanhu Wu
Xiangqing Kong
机构
[1] The First Affiliated Hospital of Nanjing Medical University,Department of Cardiology
[2] The First Affiliated Hospital of Nanjing Medical University,Department of Radiology
[3] The First Affiliated Hospital of Nanjing Medical University,Department of Cardiac Surgery
[4] Affiliated Hospital of Nantong University,Department of Cardiology
来源
The International Journal of Cardiovascular Imaging | 2009年 / 25卷
关键词
Computed tomography; Echocardiography; Aortic stenosis; Aortic regurgitation; Aortic valve area; Regurgitant orifice area;
D O I
暂无
中图分类号
学科分类号
摘要
To prospectively evaluate diagnostic accuracy of dual source computed tomography (DSCT) for evaluation of aortic stenosis (AS) and aortic regurgitation (AR) with transthoracic echocardiography (TTE) as reference. We evaluated a total of 79 patients who underwent both DSCT and TTE, 40 with aortic valve disease as assessed by TTE, and 39 matched controls. Maximum aortic valve area (AVA) in systole was planimetrically measured with DSCT, and measurements were compared with TTE, as well as maximum regurgitant orifice area (ROA) in diastole. Dimensions of the aortic root and left ventricular parameters were compared. DSCT correctly identified 30 patients with AS [sensitivity 91%, specificity 100%, positive predictive value (PPV) 100%, and negative predictive value (NPV) 94%], and 32 patients with AR (sensitivity 94%, specificity 98%, PPV 97%, and NPV 96%). A significant correlation was observed between CT planimetric size of aortic valves area and TTE (r = 0.79; P < 0.01). Bland-Altman plot demonstrates a good intermodality agreement between DSCT and TTE with a slight overestimation of AVA by DSCT (+0.14 cm2). A significant correlation was observed between CT planimetric size of ROA (0.49 cm2 ± 0.40) and TTE classification of mild, moderate and severe AR (r = 0.79; P < 0.01). With receiver operating characterisitic curve analysis, discrimination between degrees of AR with DSCT was not very accurate within cutoff ROAs. A significant correlation was observed between methods in dimensions of aortic annulus (r = 0.87, P < 0.01), sinus of Valsalva (r = 0.91, P < 0.01), and ascending aorta (r = 0.92, P < 0.01), and in end-systolic volume (r = 0.82, P< 0.01), end-diastolic volume (r = 0.87, P < 0.01) and ejection fraction (r = 0.86, P < 0.01). DSCT can provide a simultaneous and accurate evaluation of the AVA, left ventricular ejection fraction and aortic root dimensions in patients with AS or AR, but measurement of ROA is not very accurate to differentiate severity of AR. DSCT can achieve an exhaustive and comprehensive preoperative assessment of patients with AS and AR.
引用
收藏
页码:591 / 600
页数:9
相关论文
共 106 条
  • [21] Gallaugher MJ(2004)Evaluation of aortic stenosis by cardiovascular magnetic resonance imaging: comparison with established routine clinical techniques Heart 90 893-901
  • [22] O’Neill WW(2005)Dynamic cine mode imaging of the normal aortic valve using 16-channel multidetector row computed tomography Invest Radiol 40 637-647
  • [23] Gold-stein JA(2007)Sixty-four slice CT evaluation of aortic stenosis using planimetry of the aortic valve area Am J Roentgenol 189 197-203
  • [24] Juergens KU(2007)Comparison of 64-slice computed tomography planimetry and Doppler echocardiography in the assessment of aortic valve stenosis J Heart Valve Dis 16 216-224
  • [25] Grude M(1988)Analysis of the effect of flow rate on the Doppler continuity equation for stenotic orifice area calculations: a numerical study Circulation 97 1597-1605
  • [26] Mlaintz D(2008)64-MDCT for diagnosis of aortic regurgitation in patients referred to CT coronary angiography Am J Roentgenol 191 W1-7
  • [27] Raman SV(2006)Diagnostic performance of MDCT for detecting aortic valve regurgitation Am J Roentgenol 186 1676-1681
  • [28] Shah M(2008)Noninvasive evaluation of the aortic root with multislice computed tomography: implications for transcatheter aortic valve replacement J Am Coll Cardiol Imaging 1 321-330
  • [29] McCarthy B(2003)Silent and apparent cerebral embolism after retrograde catheterisation of the aortic valve in valvular stenosis: a prospective, randomised study Lancet 361 1241-1246
  • [30] Rubin GD(2002)Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description Circulation 106 3006-3008