Blood flow in the tibialis anterior muscle by photoplethysmography during foot-transmitted vibration

被引:0
|
作者
Qiuxia Zhang
Klas Ericson
Jorma Styf
机构
[1] Sahlgrenska University Hospital,Department of Orthopaedics
来源
European Journal of Applied Physiology | 2003年 / 90卷
关键词
Artefact; Filtering; Non-invasive;
D O I
暂无
中图分类号
学科分类号
摘要
Photoplethysmography (PPG) was used to detect changes in the anterior tibial muscle blood flow (MBF) during foot-transmitted vibration in six healthy subjects. A filter was developed for reducing the vibration-induced artefacts in the PPG signal. The vibration applied was random with constant acceleration power density in the range 5–2,000 Hz with an acceleration of 16–46 m s–2 (rms). The application of the filter technique showed a dramatic reduction in the vibration-induced artefacts and distortion of the PPG signal was negligible. The mean ratio and correlation coefficient of MBF originating from filtered and non-filtered PPG signals was [mean (SD)] 0.89 (0.04) and 0.99, respectively. This made it possible to detect a relative increase in MBF of 20% during an acute vibration exposure. The results suggest that the use of the filter enables MBF to be measured by PPG during vibration, thus extending the range of applications of the PPG technique to include ergonomic conditions.
引用
收藏
页码:464 / 469
页数:5
相关论文
共 50 条
  • [1] Blood flow in the tibialis anterior muscle by photoplethysmography during foot-transmitted vibration
    Zhang, QX
    Ericson, K
    Styf, J
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2003, 90 (5-6) : 464 - 469
  • [2] The effects of standing foot-transmitted vibration on self-reported discomfort ratings
    Goggins, Katie A.
    Thompson, Taryn J.
    Lessel, Courtney E.
    Kelly, Elizabeth A.
    O'Hara, Dawson E. L.
    Eger, Tammy R.
    WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2024, 78 (01): : 153 - 165
  • [3] Effects of Tibialis Anterior Muscle Vibration on Quiet Stance
    Temple, David R.
    Lee, Beom-Chan
    Layne, Charles S.
    2014 IEEE HAPTICS SYMPOSIUM (HAPTICS), 2014, : 523 - 528
  • [4] Alterations in Step Width and Reaction Times in Walking Subjects Exposed to Mediolateral Foot-Transmitted Vibration
    Marrone, Flavia
    Marelli, Stefano
    Bertozzi, Filippo
    Goggi, Alessandra
    Marchetti, Enrico
    Galli, Manuela
    Tarabini, Marco
    VIBRATION, 2024, 7 (02): : 374 - 387
  • [5] Evaluation of the inter-rater and intra-rater reliability of a protocol for the measurement of foot-transmitted vibration
    Vance, Brandon
    Goggins, Katie A.
    Godwin, Alison
    Oddson, Bruce E.
    Eger, Tammy R.
    THEORETICAL ISSUES IN ERGONOMICS SCIENCE, 2021, 22 (02) : 219 - 236
  • [6] Gender differences in muscle blood volume reduction in the tibialis anterior muscle during passive plantarflexion
    Otsuki, Aki
    Muraoka, Yoshiho
    Fujita, Emi
    Kubo, Sayaka
    Yoshida, Misaki
    Komuro, Yuko
    Ikegawa, Shigeki
    Ohta, Yuji
    Kuno-Mizumura, Mayumi
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2016, 36 (05) : 421 - 425
  • [7] The Effects of Altering the Center of Pressure in Standing Subjects Exposed to Foot-Transmitted Vibration on an Optimized Lumped-Parameter Model of the Foot
    Marelli, Stefano
    Chadefaux, Delphine
    Goggins, Katie
    Eger, Tammy
    Scaccabarozzi, Diego
    Tarabini, Marco
    VIBRATION, 2021, 4 (04): : 893 - 905
  • [8] Anatomical locations for capturing magnitude differences in foot-transmitted vibration exposure, determined using multiple correspondence analysis
    Goggins, Katie A.
    Oddson, Bruce E.
    Lievers, W. Brent
    Eger, Tammy R.
    THEORETICAL ISSUES IN ERGONOMICS SCIENCE, 2020, 21 (05) : 562 - 576
  • [9] Overall blood flow in the rabbit tibialis anterior muscle is unrelated to duty cycle and intramuscular pressure during cyclic activity
    Degens, H
    Jarvis, JC
    Salmons, S
    JOURNAL OF MUSCLE RESEARCH AND CELL MOTILITY, 1996, 17 (01) : 169 - 169
  • [10] Effects of limb elevation and increased intramuscular pressure on human tibialis anterior muscle blood flow
    Zhang, QX
    Styf, J
    Lindberg, LG
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2001, 85 (06) : 567 - 571