Chiral Ligand-Exchange Chromatography for Separation of Three Stereoisomers of Octahydroindole-2-carboxylic Acid

被引:2
|
作者
Suya Sun
Youzhi Jia
Ning Zeng
Famei Li
机构
[1] Shenyang Pharmaceutical University,
[2] Shanghai Institute of Pharmaceutical Industry,undefined
来源
Chromatographia | 2006年 / 63卷
关键词
Column liquid chromatography; Diastereo-enantio separation; Chiral mobile phase; Ligand-exchange; Octahydroindole-2-carboxylic acid;
D O I
暂无
中图分类号
学科分类号
摘要
A novel HPLC method is described for separation of the three stereoisomers of octahydroindole-2-carboxylic acid (Oic), an intermediate in the synthesis of perindopril. The chiral mobile phase contained the complex of Cu(II) with the optically active selector L-phenylalaninamide (L-PheA), and an ion-pair reagent, sodium 1-octanesulfonate. The effects of the concentrations of the Cu(II)–L-PheA complex and the ion-pair reagent, mobile phase pH, ionic strength, acetonitrile content, and column temperature were studied. Satisfactory resolution was achieved for three stereoisomers, RRR-, SSS-, and SRR-Oic.
引用
收藏
页码:331 / 335
页数:4
相关论文
共 50 条
  • [21] Solvent-Induced Conformational Flexibility of a Bicyclic Proline Analogue: Octahydroindole-2-Carboxylic Acid
    Torras, Juan
    Warren, Javier G.
    Revilla-Lopez, Guillem
    Jimenez, Ana I.
    Cativiela, Carlos
    Aleman, Carlos
    BIOPOLYMERS, 2014, 102 (02) : 176 - 190
  • [22] SEPARATION OF ENKEPHALIN DEGRADATION PRODUCTS BY LIGAND-EXCHANGE CHROMATOGRAPHY
    MAURER, R
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1980, 2 (03): : 183 - 187
  • [23] RESOLUTION OF 2-HYDROXYDICARBOXYLIC ACID ENANTIOMERS BY LIGAND-EXCHANGE CHROMATOGRAPHY ON CHEMICALLY BONDED CHIRAL PHASES
    GUBITZ, G
    MIHELLYES, S
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1994, 17 (10): : 733 - 734
  • [24] Chiral separation and determination of ofloxacin enantiomers by ionic liquid-assisted ligand-exchange chromatography
    Bi, Wentao
    Tian, Minglei
    Row, Kyung Ho
    ANALYST, 2011, 136 (02) : 379 - 387
  • [25] RESOLUTION OF AMINO-ACID ENANTIOMERS BY LIGAND-EXCHANGE CHROMATOGRAPHY ON A NEW CHIRAL PACKING
    YAN, HS
    CHENG, XH
    NI, AG
    HE, BL
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (05): : 1045 - 1055
  • [26] STUDIES IN LIGAND-EXCHANGE CHROMATOGRAPHY .4. SEPARATION OF HYDROXYBENZOIC AND HYDROXYNAPHTHOIC ACID ISOMERS
    FUJIMURA, K
    KOYAMA, T
    TANIGAWA, T
    FUNASAKA, W
    JOURNAL OF CHROMATOGRAPHY, 1973, 85 (01): : 101 - 107
  • [27] Chiral Separations by Ligand-Exchange Micellar Electrokinetic Chromatography and Microemulsion Electrokinetic Chromatography
    HUIE Carmen W
    色谱, 2004, (04) : 309 - 312
  • [28] SEPARATION OF OLIGOPEPTIDES OR AMINO-ACIDS BY LIGAND-EXCHANGE CHROMATOGRAPHY
    BOISSEAU, J
    JOUAN, P
    BULLETIN DE LA SOCIETE CHIMIQUE DE FRANCE, 1973, (01): : 153 - 155
  • [29] AMINO-ACID ANALYSIS BY LIGAND-EXCHANGE CHROMATOGRAPHY
    GEARY, S
    CEREAL SCIENCE TODAY, 1973, 18 (09): : 307 - 307
  • [30] DIRECT SEPARATION OF ENANTIOMERS BY HIGH-PERFORMANCE LIGAND-EXCHANGE CHROMATOGRAPHY ON CHEMICALLY BONDED CHIRAL PHASES
    GUBITZ, G
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1986, 9 (2-3): : 519 - 535