Objective: This is a retrospective analysis of 94 patients who underwent aortic valve replacement for predominant aortic stenosis between January 1998 and December 2004. Patients and Methods: Age ranged from 16 to 70 years (mean 43.2±13.2 years).73 were male (77.7%). Etiology was rheumatic in 71 (75.5%) and degenerative in 23 (24.5%) patients. On transthoracic echocardiography, the diameter of the aortic annulus ranged from 19 mm to 36mm (mean 28.5±3.0 mm) and the peak systolic gradients ranged from 54 mm to 174 mm of Hg (mean of 109.8±28.8 mmHg). Aortic regurgitation was absent or mild in 76 patients (80.8%) and moderate in rest. A mechanical valve was implanted in 66 patients (70.2%) and a tissue valve in 28 patients (29.8%). Valves of size 23 mm or more were implanted in 75 patients (80%). A valve of 25 mm or larger was implanted in 55 patients (54.3%). Results: There were no early deaths. Two patients required permanent pacemaker implantation for complete heart block in the immediate postoperative period. Prosthetic valve thrombosis in one patient was relieved by thrombolysis. Anticoagulant related hemorrhage was seen in two patients. One patient underwent homograft aortic valve replacement for prosthetic valve endocarditis nine months after surgery. Conclusion: Isolated aortic valve replacement in patients with predominant aortic stenosis can be performed safely by implanting an adequately large sized prosthesis, without root enlargement in a large majority of patients. © 2007 Indian Association of Cardiovascular-Thoracic Surgeons.
引用
收藏
页码:141 / 145
页数:4
相关论文
共 26 条
[1]  
Gonzalez-Juanatey J.R., Garcia-Acuna J.M., Vega Fernandez M., Et al., Influence of the size of aortic valve prostheses on hemodynamics and change in left ventricular mass: implications for the surgical management of aortic stenosis, J Thorac Cardiovasc Surg, 112, pp. 273-280, (1996)
[2]  
Connolly H.M., Oh J.K., Schaff H.V., Et al., Severe aortic stenosis with low transvalvular gradient and severe left ventricular dysfunction: result of aortic valve replacement in 52 patients, Circulation, 101, pp. 1940-1946, (2000)
[3]  
Medalion B., Blackstone E.H., Lytle B.W., White J., Arnold J.H., Cosgrove D.M., Aortic valve replacement: is valve size important?, J Thorac Cardiovasc Surg, 119, pp. 963-974, (2000)
[4]  
Teoh K.H., Fulop J.C., Weisel R.D., Et al., Aortic valve replacement with a small prosthesis, Circulation, 76, pp. 123-131, (1987)
[5]  
Kratz M., Sade R.M., Crawford Jr. F.A., Crumbley A.J., Stroud M.R., The Risk of small St. Jude Aortic Valve Prostheses, Ann Thorac Surg, 57, pp. 1114-1119, (1994)
[6]  
Sawant D., Singh A.K., Feng W.C., Bert A.A., Rotenberg F., St. Jude Medical cardiac valves in small aortic roots: follow-up to sixteen years, J Thorac Cardiovasc Surg, 113, pp. 499-509, (1997)
[7]  
Blank R.H., Pupello D.F., Bessone L.N., Harrison E.E., Sbar S., Method of managing the small aortic annulus during valve replacement, Ann Thorac Surg, 22, pp. 356-361, (1976)
[8]  
Konno S., Imai Y., Iida Y., Nakajima M., Tatsuno K., A new method for prosthetic valve replacement in congenital aortic stenosis associated with hypoplasia of the aortic valve ring, J Thorac Cardiovasc Surg, 70, pp. 909-917, (1975)
[9]  
Castro L.J., Arcidi Jr. J.M., Fisher A.L., Gaudiani V.A., Routine enlargement of the small aortic root: a preventive strategy to minimize mismatch, Ann Thorac Surg, 74, pp. 31-36, (2002)
[10]  
Sommers K.E., David T.E., Aortic valve replacement with patch enlargement of the aortic annulus, Ann Thorac Surg, 63, pp. 1608-1612, (1997)