Contrast material injection protocol with the flow rate adjusted to the heart rate for dual source CT coronary angiography

被引:0
作者
Xiaomei Zhu
Wenping Chen
Mei Li
Yi Xu
Hai Xu
Yinsu Zhu
Dehang Wang
Lijun Tang
机构
[1] The First Affiliated Hospital of Nanjing Medical University,Department of Radiology
来源
The International Journal of Cardiovascular Imaging | 2012年 / 28卷
关键词
Dual source CT; Coronary CT angiography; Contrast material; Flow rate; Heart rate;
D O I
暂无
中图分类号
学科分类号
摘要
To investigate the effect on coronary arterial attenuations of contrast material flow rate adjusted to a patient’s heart rate during dual source CT coronary angiography (DSCT-CCTA). A total of 296 consecutive patients (mean age: 58.7 years) undergoing DSCT-CCTA without previous coronary stent placement, bypass surgery, congenital or valvular heart disease were included. The image acquisition protocol was standardized (120 kV, 380 mAs) and retrospective electrocardiograph (ECG) gating was used. Patients were randomly assigned to one of three groups [flow rate: G1: dosage/16, G2: dosage/(scan time +8), G3: fixed flow rate]. The groups were compared with respect to the attenuations of the ascending aorta (AA) above coronary ostia, the left main coronary artery (LM), the proximal right coronary artery (RCA), the left anterior descending artery (LAD), the left circumflex artery (LCX), and the contrast to noise ratio of the LM (LMCNR) and the proximal RCA (RCACNR). Correlations between heart rate and attenuation of the coronary arteries were evaluated in three groups with linear regression. There was no significant difference in the three groups among the mean attenuations of AA (P = 0.141), LM (P = 0.068), RCA (P = 0.284), LMCNR (P = 0.598) and RCACNR (P = 0.546). The attenuations of the LAD and the LCX in group 1 were slightly higher than those in group 2 and 3 (P < 0.05). In group 1, the attenuations of the AA (P < 0.01), LM (P < 0.01), RCA (P < 0.01), LAD (P = 0.02) and LCX (P < 0.01) decreased, respectively, with an increasing heart rate. A similar finding was detected in group 3 (AA: P < 0.01, LM: P < 0.01, RCA: P < 0.01, LAD: P < 0.01and LCX: P < 0.01). In contrast, the attenuations of the AA (P = 0.55), LM (P = 0.27), RCA (P = 0.77), LAD (P = 0.22) and LCX (P = 0.74) had no significant correlation with heart rate in group 2. In all three groups, LMCNR (P = 0.77, 0.69 and 0.73 respectively) and RCACNR (P = 0.75, 0.39 and 0.61 respectively) had no significant correlation with heart rate. Contrast material flow rate adjusted to heart rate can diminish the influence of heart rate on attenuations of the coronary arteries in DSCT-CCTA.
引用
收藏
页码:1557 / 1565
页数:8
相关论文
共 254 条
  • [1] Hoffmann MH(2005)Noninvasive coronary angiography with multislice computed tomography Jama 293 2471-2478
  • [2] Shi H(2008)Initial evaluation of coronary images from 320-detector row computed tomography Int J Cardiovasc Imaging 24 535-546
  • [3] Schmitz BL(2009)Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography Int J Cardiovasc Imaging 25 85-90
  • [4] Schmid FT(2011)Optimal systolic and diastolic reconstruction windows for coronary CT angiography using 320-detector rows dynamic volume CT Clin Radiol 66 614-620
  • [5] Lieberknecht M(2010)Optimal systolic and diastolic image reconstruction windows for coronary 256-slice CT angiography Acad Radiol 17 1386-1393
  • [6] Schulze R(2010)Dual-source CT coronary angiography without heart rate or rhythm control in comparison with conventional coronary angiography Int J Cardiovasc Imaging 26 323-331
  • [7] Ludwig B(2005)Noninvasive coronary angiography with 16-detector row CT: effect of heart rate Radiology 234 86-97
  • [8] Kroschel U(2000)Abdominal helical CT: evaluation of optimal doses of intravenous contrast material–a prospective randomized study Radiology 216 718-723
  • [9] Jahnke N(2002)Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi-detector row helical CT Radiology 224 757-763
  • [10] Haerer W(2004)Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight Radiology 230 142-150