Inline Real-Time Near-Infrared Granule Moisture Measurements of a Continuous Granulation–Drying–Milling Process

被引:0
|
作者
Lipika Chablani
Michael K. Taylor
Amit Mehrotra
Patrick Rameas
William C. Stagner
机构
[1] Campbell University,College of Pharmacy and Health Sciences, Department of Pharmaceutical Sciences
[2] Graduate Program Mercer University,College of Pharmacy and Health Sciences
[3] BioDelivery Sciences,Pharma Launch and Global Supply
[4] GlaxoSmithKline,Pharmaceutical Development
[5] GlaxoSmithKline,undefined
来源
AAPS PharmSciTech | 2011年 / 12卷
关键词
continuous granulation–drying–milling; near-infrared (NIR) spectroscopy; process analytical technology (PAT); real-time moisture determination;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this research was to use inline real-time near-infrared (NIR) to measure the moisture content of granules manufactured using a commercial production scale continuous twin-screw granulator fluid-bed dryer milling process. A central composite response surface statistical design was used to study the effect of inlet air temperature and dew point on granule moisture content. The NIR moisture content was compared to Karl Fischer (KF) and loss on drying (LOD) moisture determinations. Using multivariate analysis, the data showed a statistically significant correlation between the conventional methods and NIR. The R2 values for predicted moisture content by NIR versus KF and predicted moisture values by NIR versus LOD were 0.94 (p < 0.00001) and 0.85 (p < 0.0002), respectively. The adjusted R2 for KF versus LOD correlation was 0.85 (p < 0.0001). Analysis of the response surface design data showed that inlet air temperature over a range of 35–55°C had a significant linear impact on granule moisture content as measured by predicted NIR (adjusted R2 = 0.84, p < 0.02), KF (adjusted R2 = 0.91, p < 0.0001), and LOD (adjusted R2 = 0.85, p < 0.0006). The inlet air dew point range of 10–20°C did not have a significant impact on any of the moisture measurements.
引用
收藏
页码:1050 / 1055
页数:5
相关论文
共 11 条
  • [1] Inline Real-Time Near-Infrared Granule Moisture Measurements of a Continuous Granulation-Drying-Milling Process
    Chablani, Lipika
    Taylor, Michael K.
    Mehrotra, Amit
    Rameas, Patrick
    Stagner, William C.
    AAPS PHARMSCITECH, 2011, 12 (04): : 1050 - 1055
  • [2] Real-Time Particle Size Analysis Using Focused Beam Reflectance Measurement as a Process Analytical Technology Tool for a Continuous Granulation–Drying–Milling Process
    Vijay Kumar
    Michael K. Taylor
    Amit Mehrotra
    William C. Stagner
    AAPS PharmSciTech, 2013, 14 : 523 - 530
  • [3] Real-Time Particle Size Analysis Using Focused Beam Reflectance Measurement as a Process Analytical Technology Tool for a Continuous Granulation-Drying-Milling Process
    Kumar, Vijay
    Taylor, Michael K.
    Mehrotra, Amit
    Stagner, William C.
    AAPS PHARMSCITECH, 2013, 14 (02): : 523 - 530
  • [4] Real-time process monitoring in a semi-continuous fluid-bed dryer - microwave resonance technology versus near-infrared spectroscopy
    Peters, Johanna
    Teske, Andreas
    Taute, Wolfgang
    Doescher, Claas
    Hoeft, Michael
    Knoechel, Reinhard
    Breitkreutz, Joerg
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2018, 537 (1-2) : 193 - 201
  • [5] Real-time near-infrared monitoring of content uniformity, moisture content, compact density, tensile strength, and Young's modulus of roller compacted powder blends
    Gupta, A
    Peck, GE
    Miller, RW
    Morris, KR
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2005, 94 (07) : 1589 - 1597
  • [6] On-Line Real-Time Monitoring of a Rapid Enzymatic Oil Degumming Process: A Feasibility Study Using Free-Run Near-Infrared Spectroscopy
    Forsberg, Jakob
    Nielsen, Per Munk
    Engelsen, Soren Balling
    Sorensen, Klavs Martin
    FOODS, 2021, 10 (10)
  • [7] AI-based analysis of in-line process endoscope images for real-time particle size measurement in a continuous pharmaceutical milling process
    Madarasz, Lajos
    Meszaros, Lilla Alexandra
    Kote, Akos
    Farkas, Attila
    Nagy, Zsombor Kristof
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2023, 641
  • [8] Real-time predictions of drug release and end point detection of a coating operation by in-line near infrared measurements
    Gendre, Claire
    Boiret, Mathieu
    Genty, Muriel
    Chaminade, Pierre
    Pean, Jean Manuel
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2011, 421 (02) : 237 - 243
  • [9] In-line and Real-time Monitoring of Resonant Acoustic Mixing by Near-infrared Spectroscopy Combined with Chemometric Technology for Process Analytical Technology Applications in Pharmaceutical Powder Blending Systems
    Tanaka, Ryoma
    Takahashi, Naoyuki
    Nakamura, Yasuaki
    Hattori, Yusuke
    Ashizawa, Kazuhide
    Otsuka, Makoto
    ANALYTICAL SCIENCES, 2017, 33 (01) : 41 - 46
  • [10] In-line and Real-time Monitoring of Resonant Acoustic Mixing by Near-infrared Spectroscopy Combined with Chemometric Technology for Process Analytical Technology Applications in Pharmaceutical Powder Blending Systems
    Ryoma Tanaka
    Naoyuki Takahashi
    Yasuaki Nakamura
    Yusuke Hattori
    Kazuhide Ashizawa
    Makoto Otsuka
    Analytical Sciences, 2017, 33 : 41 - 46