Experimental and numerical investigation on steady and transient flow in the flat-walled micro-diffuser/nozzle

被引:0
作者
Xiuhua He
Nan Lin
Wei Xu
B. B. Uzoejinwa
Zhidang Deng
机构
[1] Jiangsu University,School of Energy and Power Engineering
[2] University of Nigeria,Agricultural and Bioresources Engineering Department
[3] Jiangsu University,Faculty of Science
来源
Microsystem Technologies | 2018年 / 24卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, experiments and numerical simulations have been conducted to investigate the flow characteristics in the flat-walled micro-diffuser/nozzle on conditions of angle (0°–60°), Reynolds number (100–1500) and excitation frequency (0–5000 Hz). In steady flow, the diffuser efficiency increases with an increase in Reynolds number as θ ≤ 10°, but the optimal diffuser efficiency is found as 20° ≤ θ ≤ 60°, and the internal flow characteristics at the optimal diffuser efficiency are recorded. Based on statistics, it is concluded that the interaction of adverse pressure gradient and diverging flow results in the optimal angle, and the optimal angle decreases with an increase in Reynolds number. While in transient flow, the excitation frequency has great impacts on the optimal angle, the higher frequency results in the larger optimal angle. As the Reynolds numbers are 100 and 1500, the variations of diffuser efficiency with excitation frequency show the opposite trends. At low Reynolds number, the acceleration term caused by the excitation frequency increases the flow loss and reduces the diffuser efficiency. However, at high Reynolds number, the energy of diverging flow is stored in the vortexes and used to prevent the converging flow, this contributes to the great increase in the diffuser efficiency. Therefore, the influence of excitation frequency on the diffuser efficiency is determined by the location and intensity of the vortexes.
引用
收藏
页码:1853 / 1861
页数:8
相关论文
共 60 条
[1]  
Andersson H(2001)A valve-less diffuser micropump for microfluidic analytical systems Sens Actuators B 72 259-265
[2]  
Wijngaart WVD(2007)Study on a piezoelectric micropump for the controlled drug delivery system Microfluid Nanofluid 3 377-390
[3]  
Nilsson P(2011)A dynamic model of valveless micropumps with a fluid damping effect J Micromech Microeng 21 115016-155
[4]  
Enokssona P(2010)Fabrication and experiments of the piezoelectric micropump with novel saw-tooth microchannels Nanotechnol Precis Eng 8 149-776
[5]  
Stemme G(2012)Valveless piezoelectric micropump of parallel double chambers Int J Precis Eng Manuf 13 771-139
[6]  
Cui QF(2014)Effect of phase shift on optimal operation of serial-connected valveless micropumps Sens Actuators A 209 133-34
[7]  
Liu CL(2005)Investigation and application on micropump Fluid Mach 33 29-392
[8]  
Zha XF(2002)MEMS-micropumps: a review J Fluids Eng 124 384-597
[9]  
Dinh TX(1998)Processing and characterization of piezoelectric materials and integration into microelectromechanical systems Annu Rev Mater Res 28 563-94
[10]  
Ogami Y(2012)Multifield analysis of a piezoelectric valveless micropump: effects of actuation frequency and electric potential Smart Mater Struct 21 075002-221