Homogeneous electrogenerated chemiluminescence immunoassay for the detection of biomarkers by magnetic preconcentration on a magnetic electrode

被引:0
作者
Yuxi Wei
Yue Wang
Jiawei Wang
Xiaolin Yang
Honglan Qi
Qiang Gao
Chengxiao Zhang
机构
[1] Shaanxi Normal University,Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering
来源
Analytical and Bioanalytical Chemistry | 2019年 / 411卷
关键词
Homogeneous immunoassays; Electrogenerated chemiluminescence; Magnetic electrode; Magnetic beads; D-Dimer;
D O I
暂无
中图分类号
学科分类号
摘要
A homogeneous electrogenerated chemiluminescence (ECL) immunoassay for highly sensitive quantification of specific biomarkers based on immunomagnetic beads and homogeneous detection on a magnetic electrode was developed, for the first time. The magnetic electrode is made of a glassy carbon electrode and a series of ring permanent magnets. D-Dimer antigen was taken as a model analyte while biotinylated D-dimer antibody bound on the streptavidin-coated magnetic beads was utilized as a magnetic capture probe and ruthenium complex-labeled D-dimer antibody was employed as an ECL probe. After a fixed amount of magnetic capture probe and the ECL probe was introduced into analyte D-dimer solution, the “sandwich” immunoconjugates on the magnetic beads were formed in tested solution and then magnetically concentrated on the surface of the magnetic electrode. The homogeneous ECL immunoassay for quantification of specific biomarker was directly carried out in the presence of co-reactant tripropylamine. The low detection limit of 1 ng/mL in magnetic enrich time of 2 min and the good magnetic regeneration for the detection of D-dimer were achieved. The magnetic bead shield ECL emission was extensively discussed. This work demonstrates that the homogeneous (separation-free) ECL immunoassay using magnetic beads and magnetic electrode is a promising approach to quantify the biomarkers with high sensitivity and selectivity and in a short time. This approach can be easily extended to ECL and electrochemical biosensing for other biomarkers.
引用
收藏
页码:4203 / 4211
页数:8
相关论文
共 206 条
  • [1] Rasooly A(2006)Development of biosensors for cancer clinical testing Biosens Bioelectron 21 1851-1858
  • [2] Jacobson J(2008)Magnetic iron oxide nanoparticles: synthesis, stabilization, vectorization, physicochemical characterizations, and biological applications Chem Rev 108 2064-2110
  • [3] Laurent S(2012)Magnetic nanoparticles: design and characterization, toxicity and biocompatibility, pharmaceutical and biomedical applications Chem Rev 112 5818-5878
  • [4] Forge D(2014)Efficient collection and sensitive detection using conducting magnetic microbeads Anal Chem 86 4977-4981
  • [5] Port M(1999)An immunomagnetic electrochemical sensor based on a perfluorosulfonate-coated screen-printed electrode for the determination of 2,4-dichlorophenoxyacetic acid Anal Chem 71 2571-2577
  • [6] Roch A(2018)A highly sensitive and reliable detection of CA15-3 in patient plasma with electrochemical biosensor labeled with magnetic beads Biosens Bioelectron 122 8-15
  • [7] Robic C(2002)Magnetically-induced solid-state electrochemical detection of DNA hybridization J Am Chem Soc 124 4208-4209
  • [8] Elst LV(2006)Magnetic nanoparticles applied in electrochemical detection of controllable DNA Anal Chem 78 2447-2449
  • [9] Muller RN(2018)Rapid electrochemical assessment of tumor suppressor gene methylations in raw human serum and tumor cells and tissues using immunomagnetic beads and selective DNA hybridization Angew Chem Int Ed 57 8194-8198
  • [10] Reddy LH(2018)Rational design of magnetic micronanoelectrodes for recognition and ultrasensitive quantification of cysteine enantiomers Anal Chem 90 3374-3381