Microbubbles in the belly: optimizing the protocol for contrast-enhanced ultrasound of the pediatric abdomen

被引:0
作者
Lauramay Davis
Susan J. Back
机构
[1] University College Hospital,Institute of Nuclear Medicine
[2] Children’s Hospital of Philadelphia,Department of Radiology
[3] University of Pennsylvania,Perelman School of Medicine
来源
Pediatric Radiology | 2023年 / 53卷
关键词
Abdomen; Children; Contrast-enhanced ultrasound; Protocols; Technique; Ultrasound; Ultrasound contrast agents;
D O I
暂无
中图分类号
学科分类号
摘要
Intravenous contrast-enhanced ultrasound (CEUS) can serve as a diagnostic or problem-solving tool in pediatric imaging. CEUS of abdominal solid organs has been reported for a number of indications. The approach to the examination broadly falls into two categories: evaluation of a focal lesion or surveillance of an organ or organs for lesions or perfusion abnormalities. A consistent, technical imaging protocol for both of these clinical scenarios facilitates integration of routine use of CEUS in an imaging department. Here we review the CEUS imaging protocols for abdominal organs in children, including technical and solid-organ-specific considerations.
引用
收藏
页码:1224 / 1236
页数:12
相关论文
共 118 条
[1]  
Sridharan A(2021)Ultrasound contrast agents: microbubbles made simple for the pediatric radiologist Pediatr Radiol 51 2117-2127
[2]  
Eisenbrey JR(2013)Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS) in the liver — update 2012: a WFUMB-EFSUMB initiative in cooperation with representatives of AFSUMB, AIUM, ASUM, FLAUS and ICUS Ultrasound Med Biol 39 187-210
[3]  
Forsberg F(2017)Retrospective analysis of the safety and cost implications of pediatric contrast-enhanced ultrasound at a single center AJR Am J Roentgenol 208 446-452
[4]  
Claudon M(2022)Safety and parents acceptance of ultrasound contrast agents in children and adolescents — contrast enhanced voiding urosonography and contrast enhanced ultrasound Med Ultrason 24 27-32
[5]  
Dietrich CF(2021)Contrast-enhanced ultrasound: a comprehensive review of safety in children Pediatr Radiol 51 2161-2180
[6]  
Choi BI(2021)Expert consensus statement from the American Society of Echocardiography on hypersensitivity reactions to ultrasound enhancing agents in patients with allergy to polyethylene glycol J Am Soc Echocardiogr 34 707-708
[7]  
Yusuf GT(2013)Safety of ultrasound contrast agents in patients with known or suspected cardiac shunts Am J Cardiol 112 1039-1045
[8]  
Sellars ME(2021)Pediatric contrast-enhanced ultrasound: shedding light on the pursuit of approval in the United States Pediatr Radiol 51 2128-2138
[9]  
Deganello A(2014)Technical aspects of contrast-enhanced ultrasound (CEUS) examinations: tips and tricks Clin Hemorheol Microcirc 58 89-95
[10]  
Seelbach J(2021)Pediatric contrast-enhanced ultrasound: optimization of techniques and dosing Pediatr Radiol 51 2147-2160