Graywater treatment technologies and reuse of reclaimed water for toilet flushing

被引:0
作者
Xueli Ren
Yanyan Zhang
Hongbin Chen
机构
[1] Tongji University,State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering
来源
Environmental Science and Pollution Research | 2020年 / 27卷
关键词
Graywater; Membrane bioreactor; Biological aerated filter; Toilet flushing; Reclaimed water;
D O I
暂无
中图分类号
学科分类号
摘要
The reuse of wastewater is one effective approach to solving the problem of water resource scarcity. However, deterioration in the quality of reused water, such as increased odor and bacterial growth, restricts its reuse. The objectives of this study were to characterize graywater (GW) treatment technology and to verify the suitability of the reclaimed water for toilet flushing. A membrane bioreactor (MBR) and biological aerated filter (BAF) were used to treat GW in a 1-year laboratory-scale experiment. The optimal operational conditions of the MBR and BAF were as follows: hydraulic retention time = 2–3 h, dissolved oxygen = 4–7 mg/L, mixed liquor suspended solids = 3500–4500 mg/L, and contact reaction time = 1.96–5.89 h, dissolved oxygen = 3–5 mg/L, backwash cycle time = 24–48 h, respectively. The MBR treatment resulted in reductions in COD, NH3-N, and turbidity of 60–90%, 80–90%, and 95–99%, respectively, whereas those of BAF treatment were 50–90%, 50–90%, and 80–90%, respectively. The BOD5 values of MBR and BAF effluent were 1.2–4.5 mg/L and 2.5–7 mg/L, respectively. GW treated by both MBR and BAF met the standard for reusing water for toilet flushing. The effluent from MBR, BAF, and BAF + ultrafiltration treatment and purified mixed wastewater was used to simulate toilet flushing at 28 °C, with the addition of 5 mg/L NaClO to the reused water. The residual chlorine levels were 1.5, 0.6, 0.9, and 0.5 mg/L, respectively, after 15 days. No bacteria were detected in any of the reclaimed water after 15 days. The water quality of the effluent of MBR-treated GW was better than that of the mixed wastewater. The results show that it is viable to use GW purified by MBR for toilet flushing. This study provides a scientific basis for the popularization and application of reclaimed water for toilet flushing.
引用
收藏
页码:34653 / 34663
页数:10
相关论文
共 115 条
  • [1] Albalawneh A(2017)Greywater treatment by granular filtration system using volcanic tuff and gravel media Water Sci Technol 75 2331-2341
  • [2] Chang TK(2015)Effects of reclaimed water on the growth and fruit quality of cucumber Irrig Drain 64 370-377
  • [3] Alshawabkeh H(2017)Greywater treatment using a moving bed biofilm reactor at a university campus in Brazil J Clean Prod 142 290-296
  • [4] Chen FW(2015)Greywater treatment in airports using anaerobic filter followed by UV disinfection: an efficient and low cost alternative J Clean Prod 106 372-379
  • [5] Liu CW(2007)Grey water treatment in UASB reactor at ambient temperature Water Sci Technol 55 173-180
  • [6] Chrispim MC(2002)Characteristics of grey wastewater Urban Water 4 85-104
  • [7] Nolasco MA(2005)On-site greywater treatment and reuse in multi-storey buildings Water Sci Technol 51 187-194
  • [8] Couto EA(2007)Potential for potable water savings by using rainwater and greywater in a multi-storey residential building in southern Brazil Build Environ 42 2512-2522
  • [9] Calijuri ML(2007)Recycled vertical flow constructed wetland (RVFCW)-a novel method of recycling greywater for irrigation in small communities Chemosphere 66 916-923
  • [10] Assemany PP(2008)Monitoring of an indoor pilot plant for osmosis rejection and greywater reuse to flush toilets in a hotel Desalination 219 81-88