Assessment of skin doses in small field radiotherapy for 6 MV photons and beam spectral analysis at skin surface: an EGSnrc based Monte Carlo study

被引:0
作者
Attia Gul
M. Basim Kakakhel
Sikander M. Mirza
机构
[1] Pakistan Institute of Engineering and Applied Sciences (PIEAS),Department of Physics & Applied Mathematics
[2] Institute of Nuclear Medicine,Medical Physics Department
[3] Oncology & Radiotherapy (INOR),undefined
来源
Radiation and Environmental Biophysics | 2021年 / 60卷
关键词
Skin dose; Small fields; Spectral analysis; Monte Carlo simulation;
D O I
暂无
中图分类号
学科分类号
摘要
This study aims at the estimation of skin doses during small field radiotherapy with 6 MV photons and analysis of beam spectra at skin surface. The EGSnrc Monte Carlo code was used for spectral analysis and dose scoring in a water phantom. Percent skin dose (PSD) was calculated at a depth of 70 µm (relative to 10 cm depth), and the effects of field size, collimation, source-to-surface distance, and tissue inhomogeneity (bone/air) below the skin were evaluated. Low-energy photons and contaminant electrons from the machine head or back-scattered from underlying tissue were found to be the major contributors to skin dose. As the field size was reduced, the beam hardened, while the photon and electron fluences at the skin decreased compared to those at the reference depth of 10 cm. This resulted in a PSD reduction for fields smaller than the reference field size. Multi leaf collimators increased the PSD (up to 4%) while variation in source-to-skin dose showed a negligible effect. A substantial increase in PSD has been observed (up to 6%) when high Z material like bone was placed below the skin. In contrast, air as underlying material decreased the skin dose. The skin dose varied considerably with various clinical and geometric parameters. It is concluded that, although the skin doses were low for small fields compared to those for the reference field, skin doses may become substantial when escalated target doses are delivered with multi leaf collimators. Moreover, the presence of high Z materials such as bones or metallic implants below the skin can result in significant enhancement of the skin dose.
引用
收藏
页码:299 / 308
页数:9
相关论文
共 104 条
  • [1] Cashmore J(2016)Surface dose variations in 6 and 10 MV flattened and flattening filter-free (FFF) photon beams J Appl Clin Med Phys 17 293-307
  • [2] Chaikh A(2014)Monitoring methods for skin dose in interventional radiology Int J Cancer Ther Oncol 3 03011-34
  • [3] Gaudu A(2010)Intensity modulated radiation therapy (IMRT) surface dose measurements using a PTW advanced Markus chamber Australas Phys Eng Sci Med 33 23-2083
  • [4] Balosso J(2009)Photon beam dosimetry in the superficial buildup region using radiochromic EBT film stack Med Phys 36 2074-35
  • [5] Chen F(2008)Experimental evaluation of the accuracy of skin dose calculation for a commercial treatment planning system J Appl Clin Med Phys 9 29-26
  • [6] Gupta R(1990)Measurement of dose in the buildup region using fixed-separation plane-parallel ionization chambers Med Phys 17 17-148
  • [7] Metcalfe P(2016)Clinically relevant investigation of flattening filter-free skin dose J Appl Clin Med Phys 17 140-2898
  • [8] Chiu-Tsao ST(2004)Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting: Directional bremsstrahlung splitting Med Phys 31 2883-2386
  • [9] Chan MF(2016)Technical Report: Reference photon dosimetry data for Varian accelerators based on IROC-Houston site visit data Med Phys 43 2374-866
  • [10] Court LE(2012)An evaluation of calculation parameters in the EGSnrc/BEAMnrc Monte Carlo codes and their effect on surface dose calculation Phys Med Biol 57 N267-22