Performance of digital data acquisition system in gamma-ray spectroscopy

被引:0
|
作者
Di-Wen Luo
Hong-Yi Wu
Zhi-Huan Li
Chuan Xu
Hui Hua
Xiang-Qing Li
Xiang Wang
Shuang-Quan Zhang
Zhi-Qiang Chen
Chen-Guang Wu
Yu Jin
Jie Lin
机构
[1] Peking University,State Key Laboratory of Nuclear Physics and Technology, School of Physics
来源
关键词
Digital data acquisition system; Gamma spectroscopy; Energy resolution;
D O I
暂无
中图分类号
学科分类号
摘要
A newly developed digital data acquisition system, which is based on the digital pulse processor Pixie-16 modules by XIA LLC, was tested with the γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\gamma$$\end{document}-ray detector array of the China Institute of Atomic Energy using the γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\gamma$$\end{document}-ray source and in-beam γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\gamma$$\end{document}-rays. A comparison between this digital data acquisition system and the conventional analog data acquisition system was made. At a low count rate, both systems exhibit good and comparable energy resolutions. At a high count rate above 8.8 k/s, while the energy resolution obtained by the analog system deteriorates significantly, the energy resolution obtained by the digital system is nearly unchanged. Meanwhile, experimental data with higher statistics can be collected by the digital system. The advantage of this digital system over the conventional analog system can be ascribed to its excellent capability of handling pile-up pulses at higher count rates, and the fact that it has nearly no dead time in data transmission and conversion.
引用
收藏
相关论文
共 50 条
  • [31] ONLINE GAMMA-RAY DATA ACQUISITION AT THE POWER BURST FACILITY
    HARTWELL, JK
    KILLIAN, EW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 242 (03): : 487 - 492
  • [32] JIGSAW - A GAMMA-RAY DATA ACQUISITION, DISPLAY AND ANALYSIS PROGRAM
    HAYWOOD, SE
    BAMFORD, GJ
    RESTER, AC
    COLDWELL, RL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) : 901 - 903
  • [33] Performance of NaI(Tl) detector for gamma-ray spectroscopy
    Akkurt, Iskender
    Waheed, Faez
    Akyildirim, Hakan
    Gunoglu, Kadir
    INDIAN JOURNAL OF PHYSICS, 2022, 96 (10) : 2941 - 2947
  • [34] Performance of NaI(Tl) detector for gamma-ray spectroscopy
    İskender Akkurt
    Faez Waheed
    Hakan Akyildirim
    Kadir Gunoglu
    Indian Journal of Physics, 2022, 96 : 2941 - 2947
  • [35] Gamma-ray spectroscopy at ganil
    De France, G.
    INTERNATIONAL JOURNAL OF MODERN PHYSICS E-NUCLEAR PHYSICS, 2006, 15 (08) : 1957 - 1965
  • [36] Solar Gamma-Ray Spectroscopy
    R. J. Murphy
    Space Science Reviews, 2007, 130 : 127 - 138
  • [37] Gamma-ray spectroscopy with gammasphere
    Macchiavelli, AO
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 82 - NUCL
  • [38] A novel sorting algorithm and its application to a gamma-ray telescope asynchronous data acquisition system
    Colavita, A
    Mumolo, E
    Capello, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 394 (03): : 374 - 380
  • [39] Improvement of a high speed and high density data acquisition system for multiple gamma-ray detection
    Kimura, Atsushi
    Toh, Yosuke
    Koizumi, Mitsuo
    Furutaka, Kazuyoshi
    Kin, Tadahiro
    Oshima, Masumi
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 474 - 477
  • [40] Gamma-ray burst spectroscopy
    Preece, RD
    GAMMA-RAY BURSTS, 2000, 526 : 115 - 124