Performance of digital data acquisition system in gamma-ray spectroscopy

被引:0
作者
Di-Wen Luo
Hong-Yi Wu
Zhi-Huan Li
Chuan Xu
Hui Hua
Xiang-Qing Li
Xiang Wang
Shuang-Quan Zhang
Zhi-Qiang Chen
Chen-Guang Wu
Yu Jin
Jie Lin
机构
[1] Peking University,State Key Laboratory of Nuclear Physics and Technology, School of Physics
来源
Nuclear Science and Techniques | 2021年 / 32卷
关键词
Digital data acquisition system; Gamma spectroscopy; Energy resolution;
D O I
暂无
中图分类号
学科分类号
摘要
A newly developed digital data acquisition system, which is based on the digital pulse processor Pixie-16 modules by XIA LLC, was tested with the γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\gamma$$\end{document}-ray detector array of the China Institute of Atomic Energy using the γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\gamma$$\end{document}-ray source and in-beam γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\gamma$$\end{document}-rays. A comparison between this digital data acquisition system and the conventional analog data acquisition system was made. At a low count rate, both systems exhibit good and comparable energy resolutions. At a high count rate above 8.8 k/s, while the energy resolution obtained by the analog system deteriorates significantly, the energy resolution obtained by the digital system is nearly unchanged. Meanwhile, experimental data with higher statistics can be collected by the digital system. The advantage of this digital system over the conventional analog system can be ascribed to its excellent capability of handling pile-up pulses at higher count rates, and the fact that it has nearly no dead time in data transmission and conversion.
引用
收藏
相关论文
共 70 条
[1]  
Eberth J(2008)From Ge(Li) detectors to gamma-ray tracking arrays-50 years of gamma spectroscopy with germanium detectors Prog. Part. Nucl. Phys. 60 283-337
[2]  
Simpson J(2016)High resolution gamma-ray spectroscopy and the fascinating angular momentum realm of the atomic nucleus Phys. Scr. 91 123002-378
[3]  
Riley MA(1999)Comparison of analog and digital signal processing systems using pulsers Nucl. Instrum. Methods Phys. A 422 373-1468
[4]  
Simpson J(2004)Comparison of a digital and an analog signal processing system for neutron inelastic gamma-ray spectrometry Appl. Radiat. Isot. 61 1463-358
[5]  
Paul ES(2006)Current trends in developing digital signal processing electronics for semiconductor detectors Nucl. Instrum. Methods Phys. A 568 350-690
[6]  
Koskelo MJ(2010)Comparison of digital and analogue data acquisition systems for nuclear spectroscopy Nucl. Instrum. Methods Phys. A 624 684-440
[7]  
Koskelo IJ(2013)An acquisition system of digital nuclear signal processing for the algorithm development. Nucl. Sci. Tech. 24 060408-90
[8]  
Sielaff B(2021)Design of a 20-Gsps 12-bit time-interleaved analog-to-digital conversion system Nucl. Sci. Tech. 32 25-542
[9]  
Mitra S(2005)TIGRESS highly-segmented high-purity germanium clover detector Nucl. Instrum. Methods Phys. A 543 431-498
[10]  
Wielopolski L(2008)The TIGRESS DAQ/trigger system IEEE Trans. Nucl. Sci. 55 84-709