Adaptability of n–γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upgamma$$\end{document} discrimination and filtering methods based on plastic scintillation

被引:0
作者
Zhuo Zuo
Hao-Ran Liu
Yu-Cheng Yan
Bing-Qi Liu
Song Zhang
机构
[1] Chengdu University of Technology College of Engineering Technology,
[2] Southwest Institute of Physics,undefined
[3] Chengdu University,undefined
[4] Chengdu University of Technology,undefined
关键词
Fourier transform; Wavelet transform; Moving average; Kalman filter; Charge comparison method; Fractal spectrum method; Back-propagation neural network;
D O I
10.1007/s41365-021-00865-3
中图分类号
学科分类号
摘要
Neutrons have been extensively used in many fields, such as nuclear physics, biology, geology, medical science, and national defense, owing to their unique penetration characteristics. Gamma rays are usually accompanied by the detection of neutrons. The capability to discriminate neutrons from gamma rays is important for evaluating plastic scintillator neutron detectors because similar pulse shapes are generated from both forms of radiation in the detection system. The pulse signals measured by plastic scintillators contain noise, which decreases the accuracy of n–γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upgamma$$\end{document} discrimination. To improve the performance of n–γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upgamma$$\end{document} discrimination, the noise of the pulse signals should be filtered before the n–γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upgamma$$\end{document} discrimination process. In this study, the influences of the Fourier transform, wavelet transform, moving-average filter, and Kalman algorithm on the charge comparison method, fractal spectrum method, and back-propagation neural network methods were studied. It was found that the Fourier transform filtering algorithm exhibits better adaptability to the charge comparison method than others, with an increasing accuracy of 6.87% compared to that without the filtering process. Meanwhile, the Kalman filter offers an improvement of 3.04% over the fractal spectrum method, and the adaptability of the moving-average filter in back-propagation neural network discrimination is better than that in other methods, with an increase in 8.48%. The Kalman filtering algorithm has a significant impact on the peak value of the pulse, reaching 4.49%, and it has an insignificant impact on the energy resolution of the spectrum measurement after discrimination.
引用
收藏
相关论文
共 74 条
  • [1] Tang B(2020)Experimental study of silicon carbide neutron detectors J. Radiat. Res. Radiat. Process. 38 67-72
  • [2] Cai J(2019)A method for material identification based on X-ray dual-energy backscatter detection Nuclear Tech. 42 060201-23
  • [3] Huang WB(2020)Development of a 4 Nuclear Tech. 43 050401-13
  • [4] Shen TM(2019)-phoswich detector for measuring radioactive inert gases Nuclear Tech. 42 070401-192
  • [5] Chen JM(2013)Neutron detection efficiency and gamma discrimination of boron-coated straw detectors Nucl. Instrum. Methods Phys. Res. A 723 19-2624
  • [6] Li WJ(2015)Pulse shape discrimination in the plastic scintillator EJ-299-33 Nuclear Tech. 38 020501-18
  • [7] Zhou DD(2012)Pulse shape discrimination and energy calibration of EJ301 liquid scintillation detector Nucl. Instrum. Methods Phys. Res. Sect. A 687 7-83
  • [8] You SM(2014)Digital delay-line-shaping method for pulse shape discrimination in stilbene neutron detectors and application to fusion neutron measurement at the HL-2A tokamak Nucl. Instrum. Methods Phys. Res. A 767 188-17
  • [9] Xin J(2016)Plutonium metal vs. oxide determination with the pulse-shape-discrimination-capable plastic scintillator EJ-299-33 Chin. Phys. C 40 066201-1405
  • [10] Zeng J(2009)A fractal spectrum approach for neutron and gamma pulse shape discrimination was supported by the National Natural Science Foundation of China (41274109), Sichuan Youth Science and Technology Innovation Research Team (2015TD0020), Scientific and Technology IEEE Trans. Nucl. Sci. 57 2617-1095