Research on the Corrosion Behavior of X70 Pipeline Steel Under Coupling Effect of AC + DC and Stress

被引:0
作者
Xinhua Wang
Zuquan Wang
Yingchun Chen
Xuting Song
Cheng Xu
机构
[1] Beijing University of Technology,
来源
Journal of Materials Engineering and Performance | 2019年 / 28卷
关键词
alternating current; direct current; pitting corrosion; stress; X70 pipeline steel;
D O I
暂无
中图分类号
学科分类号
摘要
The coupling effect of stray AC (alternating current) + DC (direct current) and tensile stress-induced X70 pipeline corrosion is complicated with its mechanism uncovered. In this work, the corrosion behavior of X70 pipeline steel under three different corrosion (including an individual AC corrosion, mixed AC + 150 MPa tensile stress corrosion, coupling effect of AC + a 30 A/m2 DC interference and 150 MPa tensile stress corrosion) conditions in Dagang soil simulated solution was investigated by COMSOL Multiphysics software simulation, electrochemical tests, scanning electron microscope and other techniques. The results indicated that with the increase in AC density, the open-circuit potential of the X70 steel samples was negatively shifted and corrosion rate increased in three different corrosion conditions. The corrosion rates of X70 steel samples under individual AC interference were almost unchanged when 150.9 MPa tensile stress was applied. When applying 30 A/m2 DC interference, the corrosion rate of X70 steel increases significantly. Therefore, the factors affecting corrosion performance of X70 pipeline steel were DC > AC > stress. Under individual AC interference, uniform corrosion occurred on the X70 steel at an AC current density of less than 30 A/m2, while the pitting corrosion occurred at an AC current density of greater than 100 A/m2. The application of tensile stress and DC had a certain inhibitory effect on pitting corrosion.
引用
收藏
页码:1958 / 1968
页数:10
相关论文
共 95 条
[1]  
Allahkaram SR(2015)Investigation on Corrosion Rate and a Novel Corrosion Criterion for Gas Pipelines Affected by Dynamic Stray Current J. Nat. Gas Sci. Eng. 26 453-460
[2]  
Isakhani-Zakaria M(2013)Experimental Observations of Stray Current Effects on Steel Fibres Embedded in Mortar Corros. Sci. 74 1-12
[3]  
Derakhshani M(2013)Stray Current Corrosion in Buried Pipeline Anti-Corros. Methods Mater. 58 234-237
[4]  
Solgaard AOS(2007)Corrosion Behaviour of Steel in Concrete in the Presence of Stray Current Corros. Sci. 49 1056-1068
[5]  
Carsana M(2013)Experiment Research of Dynamic Stray Current Interference on Buried Gas Pipeline from Urban Rail Transit J. Nat. Gas Sci. Eng. 15 76-81
[6]  
Geiker MR(2017)Corrosive Effects of the Electromagnetic Induction Caused by the High Voltage Power Lines on Buried X70 Steel Pipelines Int. J. Electr. Power Energy Syst. 91 34-41
[7]  
Zhu Q(2013)Effects of Vehicle Running Mode on Rail Potential and Stray Current in DC Mass Transit Systems IEEE Trans. Veh. Technol. 62 3569-3580
[8]  
Cao A(2015)Corrosion Behavior of Carbon Steel in Interference of Stray Current and Cathodic Protection Surf. Technol. 44 12-18
[9]  
Wang Z(2017)Method for Diagnosis of the Effect of AC on the X70 Pipeline Due to an Inductive Coupling Caused by HVPL IET Sci. Meas. Technol. 11 766-772
[10]  