A non-enzymatic voltammetric xanthine sensor based on the use of platinum nanoparticles loaded with a metal-organic framework of type MIL-101(Cr). Application to simultaneous detection of dopamine, uric acid, xanthine and hypoxanthine

被引:0
作者
Li Zhang
Shaobin Li
Jianjiao Xin
Huiyuan Ma
Haijun Pang
Lichao Tan
Xinming Wang
机构
[1] Harbin University of Science and Technology,School of Materials Science and Engineering, College of Chemical and Environmental Engineering
[2] Qiqihar University,College of Materials Science and Engineering, Heilongjiang Provincial Key Laboratory of Polymeric Composite Materials
来源
Microchimica Acta | 2019年 / 186卷
关键词
Metal-organic frameworks; Metal nanoparticles; Electrochemistry; Non-enzymatic sensor; Glassy carbon electrode; Cyclic voltammetry; Differential pulse voltammetry; Electrochemical impedance spectroscopy; Human serum; Standard addition method;
D O I
暂无
中图分类号
学科分类号
摘要
A Cr-based metal-organic framework MIL-101(Cr) was used to load platinum nanoparticles (PtNPs) that were placed on a glassy carbon electrode (GCE). The modified GCE was used as a non-enzymatic xanthine sensor. Compared to bare GCE, it requires a strongly decreased working potential and an increased signal current for xanthine oxidation. This is due to the crystalline ordered structure and large specific surface of the MIL-101(Cr), and to the high conductivity of the Pt NPs. Differential pulse voltammetry (DPV) shows the sensor to have a wide linear range (0.5 – 162 μM), a low detection limit (0.42 μM), and high selectivity. It was applied to the simultaneous determination of dopamine, uric acid, xanthine and hypoxanthine at working potentials of 0.13, 0.28, 0.68 and 1.05 V, respectively (vs. Ag/AgCl) and to quantify xanthine in spiked serum samples.
引用
收藏
相关论文
共 246 条
[1]  
Mu SL(2013)Xanthine biosensor based on the direct oxidation of xanthine at an electrogenerated oligomer film Biosens Bioelectron 47 429-435
[2]  
Shi QF(2002)A quantitative method for the analysis of xanthine alkaloids in Paullinia cupana (guarana) by capillary column gas chromatography J Sep Sci 25 371-374
[3]  
Pagliarussia RS(2006)Quantification of uric acid, xanthine and hypoxanthine in human serum by HPLC for pharmacodynamic studies J Chromatogr B 837 1-10
[4]  
Freitasa LAP(1989)A sensitive fluorometric assay for measuring xanthine dehydrogenase and oxidase in tissues Free Radical Bio Med 6 607-615
[5]  
Bastosa JK(1994)Fibre-optic biosensor for hypoxanthine and xanthine based on a chemiluminescence reaction Biosens Bioelectron 9 189-195
[6]  
Cooper N(2005)Three-way partial least-squares regression for the simultaneous kinetic-enzymatic determination of xanthine and hypoxanthine in human urine Anal Bioanal Chem 382 1380-1388
[7]  
Khosravan R(2009)Development of a high analytical performance-xanthine biosensor based on layered double hydroxides modified-electrode and investigation of the inhibitory effect by allopurinol Biosens Bioelectron 24 1171-1176
[8]  
Erdmann C(2010)The electrochemical study of catecholamine reactions in the presence of nitrite ion under mild acidic conditions Electrochim Acta 55 1809-1813
[9]  
Fiene J(2018)Ultrasensitive binder-free glucose sensors based on the pyrolysis of in situ grown cu MOF Sensor Actuat B-Chem 254 272-281
[10]  
Lee JW(2018)Facile fabrication of a non-enzymatic nanocomposite of heteropolyacids and CeO Electrochim Acta 266 54-65