Long-term results of tissue-engineered small-caliber vascular grafts in a rat carotid arterial replacement model

被引:0
作者
Fumiaki Kuwabara
Yuji Narita
Aika Yamawaki-Ogata
Makoto Satake
Hiroaki Kaneko
Hideki Oshima
Akihiko Usui
Yuichi Ueda
机构
[1] Gifu Prefectural Tajimi Hospital,Department of Cardiovascular Surgery
[2] Nagoya University Graduate School of Medicine,Department of Cardiac Surgery
[3] Teijin Limited,Technology Innovation Center
来源
Journal of Artificial Organs | 2012年 / 15卷
关键词
Tissue engineering; Small-caliber vascular graft; Long-term result;
D O I
暂无
中图分类号
学科分类号
摘要
The concept of tissue engineered small-caliber vascular grafts (TE-SCVGs) is theoretically ideal. In this study, we evaluated the long-term (more than 1 year) course of TE-SCVGs using a rat carotid arterial replacement model. We fabricated a TE-SCVG scaffold (0.7 mm in diameter) with electrospun nano-scale fibers. Poly-ε-caprolactone was used as a biodegradable polymer. These artificial vessels were then used in carotid arterial replacement performed on Sprague–Dawley rats. The implanted grafts were removed at an early phase (1, 2, 6 weeks), middle phase (12, 24 weeks), and late phase (48, 72 weeks) after implantation. Twenty-nine patent grafts from among the 40 implanted grafts (patency 72.5 %) could be evaluated. No aneurysm formation was observed during the follow-up period. Endothelial cells positive for immunostaining with von Willebrand factor were found to be already attached to the inner surface of the TE-SCVGs in the early phase. The percentage of smooth muscle cell specific marker (α-smooth muscle actin and calponin with fluorescent immunostaining) positive cells, which seemed to be mesenchymal cells in the graft wall, increased with time, while, in contrast, the scaffold material decreased. Even after 72 weeks, however, although the scaffold material had degraded, it had not disappeared completely. These results show that the novel TE-SCVGs we developed were still functioning in the rat carotid arterial circulation after more than 1 year. However, further investigations will be required with regard to regeneration of the SMC layer and the complete degradation of graft materials.
引用
收藏
页码:399 / 405
页数:6
相关论文
共 44 条
  • [41] Long-Term Results of Cell-Free Biodegradable Scaffolds for In Situ Tissue-Engineering Pulmonary Artery in a Canine Model
    Matsumura, Goki
    Matsuda, Shojiro
    Isayama, Noriko
    Sakamoto, Yuki
    Ikada, Yoshito
    Yamazaki, Kenji
    CIRCULATION, 2012, 126 (21)
  • [42] Comparison of Synthetic Small-Calibre Biodegradable vs. Stable ePTFE Vascular Prosthesis After Long-term Implantation in the Rat Aorta
    Mugnai, Damiano
    de Valence, Sarra
    Mrowczynski, Wojciech
    Tille, Jean-Christophe
    Montet, Xavier
    Gurny, Robert
    Kalangos, Afksendiyos
    Moeller, Michael
    Walpoth, Beat H.
    CIRCULATION, 2011, 124 (21)
  • [43] In vitro Flow Perfusion Maintaining Long-term Viability of the Rat Groin Fat Flap: A Novel Model for Research on Large-scale Engineered Tissues
    An Yang
    Nie Fang-Fei
    Qin Ze-Lian
    Xue Hong-Yu
    Chen Lu-Jia
    Li Bi
    Li Dong
    中华医学杂志英文版, 2018, 131 (02) : 213 - 217
  • [44] In vitro Flow Perfusion Maintaining Long-term Viability of the Rat Groin Fat Flap: A Novel Model for Research on Large-scale Engineered Tissues
    An, Yang
    Nie, Fang-Fei
    Qin, Ze-Lian
    Xue, Hong-Yu
    Chen, Lu-Jia
    Li, Bi
    Li, Dong
    CHINESE MEDICAL JOURNAL, 2018, 131 (02) : 213 - 217