Compensation of motion artifacts in intracoronary optical frequency domain imaging and optical coherence tomography

被引:0
作者
Jinyong Ha
Hongki Yoo
Guillermo J. Tearney
Brett E. Bouma
机构
[1] Massachusetts General Hospital,Harvard Medical School, Wellman Center for Photomedicine
来源
The International Journal of Cardiovascular Imaging | 2012年 / 28卷
关键词
Motion artifacts; Image compensation; OCT; OFDI;
D O I
暂无
中图分类号
学科分类号
摘要
Intracoronary optical coherence tomography and optical frequency domain imaging (OFDI) have been utilized for two-dimensional and three-dimensional imaging of vascular microanatomy. Image quality and the spatial accuracy of multidimensional reconstructions, however, can be degraded due to artifacts resulting from relative motion between the intracoronary catheter and the vessel wall. To track the relative motion of a catheter with regard to the vessel, a motion tracking system was incorporated with a standard OFDI system by using wavelength division multiplexing techniques. Motion of the vessel was acquired by a frequency shift of the backscattered light caused by the Doppler effect. A single monochromatic beam was utilized for tracking the relative longitudinal displacements of a catheter-based fiber probe with regard to the vessel. Although two tracking beams are, in general, required to correct for longitudinal motion artifacts, the accurate reconstruction in a longitudinal view was achieved by the Doppler frequency information of a single beam. Our results demonstrate that the single beam based motion tracking scheme is a cost-effective, practical approach to compensating for longitudinal distortions due to cardiac dynamics, thus leading to accurate quantitative analysis of 3D intracoronary OFDI.
引用
收藏
页码:1299 / 1304
页数:5
相关论文
共 51 条
[1]  
Huang D(1991)Optical coherence tomography Science 254 1178-609
[2]  
Swanson EA(2002)Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound J Am Coll Cardiol 39 604-2963
[3]  
Lin CP(2003)High-speed optical frequency-domain imaging Opt Express 11 2953-2189
[4]  
Schuman JS(2003)Sensitivity advantage of swept source and Fourier domain optical coherence tomography Opt Express 11 2183-1433
[5]  
Stinson WG(2006)Comprehensive volumetric optical microscopy in vivo Nat Med 12 1429-761
[6]  
Chang W(2008)Three-dimensional coronary artery microscopy by intracoronary optical frequency domain imaging JACC Cardiovasc Imaging 1 752-206
[7]  
Jang IK(2010)Advantage of next-generation frequency-domain optical coherence tomography compared with conventional time-domain system in the assessment of coronary lesion Catheter Cardiovasc Interv 75 202-196
[8]  
Bouma BE(2010)A case of lipid core plaque progression and rupture at the edge of a coronary stent: elucidating the mechanisms of DES failure Circ Cardiovasc Interv 3 193-11427
[9]  
Kang DH(2010)Compensation of motion artifacts in catheter-based optical frequency domain imaging Opt Express 18 11418-undefined
[10]  
Park SJ(undefined)undefined undefined undefined undefined-undefined