Design and experimental analysis of counter-flow heat and mass exchanger incorporating (M-cycle) for evaporative cooling

被引:0
作者
Omar Khalid
Zubair Butt
Waqas Tanveer
Hasan Iqbal Rao
机构
[1] UET Taxila,Department of Mechanical Engineering
[2] UET Taxila,Department of Mechatronics Engineering
来源
Heat and Mass Transfer | 2017年 / 53卷
关键词
Humidity Ratio; Evaporative Cool System; Mass Exchanger; Direct Evaporative Cool; Feed Water Temperature;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, the functioning of dew-point cooler is improved in terms of its thermal effectiveness. For this reason, a heat and mass exchanger has been designed by using a counter-flow pattern incorporating Maisotsenko cycle (M-cycle) having effective absorbing material called Kraft paper on wet channel side and improved width to height ratio. Experimentation has been performed under various inlet air working parameters such as humidity, velocity and temperature in addition with changing feed water temperature. The results from the experiments specify that the dew-point and the wet-bulb effectiveness is achieved between 67–87 % and 104–120 % respectively. Analysis is performed with temperature variation between 25 and 45 °C at different absolute humidity levels ranging from 14.4 to 18 g/kg, while the inlet air velocity is varied between 0.88 and 1.50 m/s. Thus, the working ability of the improved design has been found 5 % more effective in terms of wet bulb effectiveness as compared to previous counter-flow designs.
引用
收藏
页码:1391 / 1403
页数:12
相关论文
共 28 条
[1]  
Zhan C(2011)Comparative study of the performance of the M-Cycle counter-flow and cross-flow heat exchangers for indirect evaporative cooling paving the path toward sustainable cooling of buildings Energy Build 36 6790-6805
[2]  
Zhao X(2011)Exergetic and sustainability performance comparison of novel and conventional air cooling systems for building applications Energy Build 43 146-172
[3]  
Caliskan H(2005)Study on the heat transfer characteristics of an evaporative cooling tower Int Commun Heat Mass Transf 32 1066-1074
[4]  
Dincer I(2008)Numerical study of a novel counter-flow heat and mass exchanger for dew point evaporative cooling Appl Therm Eng 28 1942-1951
[5]  
Hepbasli A(2003)A new ideal evaporative freezing cycle Int J Heat Mass Transf 46 2967-2974
[6]  
Naphon P(2010)Experimental characterization of the operation and comparative study of two semi-indirect evaporative systems Appl Therm Eng 30 1447-1454
[7]  
Zhao X(1981)A general theory of wet surface heat exchangers and its application to regenerative evaporative cooling J Heat Transf 103 579-585
[8]  
Li JM(1989)Optimization of wet-surface heat exchangers Energy Build 14 757-770
[9]  
Riffat SB(1998)Effectiveness of cross flow plate heat exchanger for indirect evaporative cooling Int J Refrig 21 463-471
[10]  
Cerci Y(2011)Numerical study of a M-Cycle cross flow heat exchanger for indirect evaporative cooling Build Environ 46 657-668