Extraction of plasma from whole blood using a deposited microbead plug (DMBP) in a capillary-driven microfluidic device

被引:0
作者
Chunyu Li
Chong Liu
Zheng Xu
Jingmin Li
机构
[1] Dalian University of Technology,Key Laboratory for Micro/Nano Technology and System of Liaoning Province
来源
Biomedical Microdevices | 2012年 / 14卷
关键词
Deposited microbead plug (DMBP); Plasma extraction; Capillary force; Microfluidics;
D O I
暂无
中图分类号
学科分类号
摘要
We presented a deposited microbead plug (DMBP)-based microfluidic device capable of extracting plasma from whole blood by capillary forces. This device was fabricated by reversibly bonding a PDMS slab with a straight channel to a hydrophilic glass substrate. The DMBP was easily constructed at the inlet of the channel within 2 min by a method of natural deposition of microbeads without the need of weirs or photopolymerization. Capillary forces generated mainly on the hydrophilic glass substrate provided a driving force during the fabrication of the DMBP and plasma extraction, resulting in simplicity of operations. The DMBP only allows blood plasma to pass through but blocks blood cells, which was demonstrated experimentally using sheep blood. The DMBP enabled to remain in its initial configuration during plasma extraction. The high quality plasma was obtained without contamination of microbeads and blood cells. This easy-to-use, easy-to-integrate, disposable the DMBP-based microfluidic device has the potential to be integrated with on-chip bioanalytical units for the applications of point-of-care diagnostics.
引用
收藏
页码:565 / 572
页数:7
相关论文
共 152 条
  • [1] Blattert C(2004)Separation of blood in microchannel bends Conf. Proc. IEEE Eng. Med. Biol. Soc. 4 2627-2630
  • [2] Jurischka R(2006)Deterministic hydrodynamics: taking blood apart Proc. Natl. Acad. Sci. U. S. A. 103 14779-14784
  • [3] Tahhan I(1998)Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) Anal. Chem. 70 4974-4984
  • [4] Schoth A(2006)Geometrical focusing of cells in a microfluidic device: An approach to separate blood plasma Biorheology. 43 147-159
  • [5] Kerth P(2008)Integrated barcode chips for rapid, multiplexed analysis of proteins in microliter quantities of blood Nat. Biotechnol. 26 1373-1378
  • [6] Menz W(2010)Surface acoustic wave actuated cell sorting (SAWACS) Lab Chip 10 789-794
  • [7] Davis JA(2006)Centrifugal extraction of plasma from whole blood on a rotating disk Lab Chip 6 776-781
  • [8] Inglis DW(2004)Continuous microfluidic immunomagnetic cell separation Appl. Phys. Lett. 85 5093-5095
  • [9] Morton KJ(2008)Silicon-based microfilters for whole blood cell separation Biomed. Microdevices 10 251-257
  • [10] Lawrence DA(2010)Plasma extraction in a capillary-driven microfluidic device using surfactant-added poly(dimethylsiloxane) Sensor Actuat B-Chem. 145 861-868