Electrochemical Prevention of Needle-Tract Seeding

被引:0
作者
Antoni Ivorra
机构
[1] Universitat Pompeu Fabra,Department of Information and Communication Technologies
来源
Annals of Biomedical Engineering | 2011年 / 39卷
关键词
Neoplasm seeding; Needle-tract seeding; Tumor cell dissemination; Electrochemical treatment;
D O I
暂无
中图分类号
学科分类号
摘要
Needle-tract seeding refers to the implantation of tumor cells by contamination when instruments, such as biopsy needles, are employed to examine, excise, or ablate a tumor. The incidence of this iatrogenic phenomenon is low but it entails serious consequences. Here, as a new method for preventing neoplasm seeding, it is proposed to cause electrochemical reactions at the instrument surface so that a toxic microenvironment is formed. In particular, the instrument shaft would act as the cathode, and the tissues would act as the electrolyte in an electrolysis cell. By employing numerical models and experimental observations reported by researchers on Electrochemical Treatment of tumors, it is numerically showed that a sufficiently toxic environment of supraphysiological pH can be created in a few seconds without excessive heating. Then, by employing an ex vivo model consisting of meat pieces, validity of the conclusions provided by the numerical model concerning pH evolution is confirmed. Furthermore, a simplified in vitro model based on bacteria, instead of tumor cells, is implemented for showing the plausibility of the method. Depending on the geometry of the instrument, suitable current densities will probably range from about 5 to 200 mA/cm2, and the duration of DC current delivery will range from a few seconds to a few minutes.
引用
收藏
页码:2080 / 2089
页数:9
相关论文
共 89 条
  • [1] Castillo OA(2008)Port site metastasis and tumor seeding in oncologic laparoscopic urology Urology 71 372-378
  • [2] Vitagliano G(2003)Theoretical analysis of the thermal effects during in vivo tissue electroporation Bioelectrochemistry 61 99-107
  • [3] Davalos RV(2005)Radiofrequency cauterization: an alternative to reduce post-biopsy hemorrhage Cardiovasc. Intervent. Radiol. 28 681-682
  • [4] Rubinsky B(2002)Liver electrolysis: pH can reliably monitor the extent of hepatic ablation in pigs Clin. Sci. (Lond.) 102 389-395
  • [5] Mir LM(1996)The dielectric properties of biological tissues: I. Literature survey Phys. Med. Biol. 41 2231-2249
  • [6] Dromi SA(2001)Cell membrane electropermeabilization by symmetrical bipolar rectangular pulses. Part II. Reduced electrolytic contamination Bioelectrochemistry 54 91-95
  • [7] Locklin J(2006)Does stereotactic core needle biopsy increase the risk of local recurrence of invasive breast cancer? Breast J. 12 191-193
  • [8] Wood BJ(2003)Postbiopsy bleeding in a porcine model: reduction with radio-frequency ablation—preliminary results Radiology 227 493-499
  • [9] Finch JG(2007)Needle tract implantation of hepatocellular carcinoma after fine needle biopsy Dig. Dis. Sci. 52 228-231
  • [10] Fosh B(1947)Studies of thermal injury: II. The relative importance of time and surface temperature in the causation of cutaneous burns Am. J. Pathol. 23 695-720