In-line Filtration Decreases Systemic Inflammatory Response Syndrome, Renal and Hematologic Dysfunction in Pediatric Cardiac Intensive Care Patients

被引:0
作者
Michael Sasse
Friederike Dziuba
Thomas Jack
Harald Köditz
Torsten Kaussen
Harald Bertram
Philipp Beerbaum
Martin Boehne
机构
[1] Hannover Medical School,Department of Pediatric Cardiology and Intensive Care Medicine
来源
Pediatric Cardiology | 2015年 / 36卷
关键词
In-line filtration; Cardiac surgery; SIRS; Intensive care; Particle; Inflammation;
D O I
暂无
中图分类号
学科分类号
摘要
Cardiac surgery with cardiopulmonary bypass (CPB) frequently leads to systemic inflammatory response syndrome (SIRS) with concomitant organ malfunction. Infused particles may exacerbate inflammatory syndromes since they activate the coagulation cascade and alter inflammatory response or microvascular perfusion. In a randomized, controlled, prospective trial, we have previously shown that particle-retentive in-line filtration prevented major complications in critically ill children. Now, we investigated the effect of in-line filtration on major complications in the subgroup of cardiac patients. Children admitted to tertiary pediatric intensive care unit were randomized to either control or filter group obtaining in-line filtration throughout complete infusion therapy. Risk differences and 95 % confidence intervals (CI) of several complications such as SIRS, sepsis, mortality, various organ failure and dysfunction were compared between both groups using the Wald method. 305 children (n = 150 control, n = 155 filter group) with cardiac diseases were finally analyzed. The majority was admitted after cardiac surgery with CPB. Risk of SIRS (−11.3 %; 95 % CI −21.8 to −0.5 %), renal (−10.0 %; 95 % CI −17.0 to −3.0 %) and hematologic (−8.1 %; 95 % CI −14.2 to −0.2 %) dysfunction were significantly decreased within the filter group. No risk differences were demonstrated for occurrence of sepsis, any other organ failure or dysfunctions between both groups. Infused particles might aggravate a systemic hypercoagulability and inflammation with subsequent organ malfunction in pediatric cardiac intensive care patients. Particle-retentive in-line filtration might be effective in preventing SIRS and maintaining renal and hematologic function. In-line filtration offers a novel therapeutic option to decrease morbidity in cardiac intensive care.
引用
收藏
页码:1270 / 1278
页数:8
相关论文
共 222 条
[1]  
Abu-Omar Y(2006)Cardiopulmonary bypass and renal injury Perfusion 21 209-213
[2]  
Ratnatunga C(2005)Effect of congenital heart disease on renal function in childhood Nephron Physiol 99 p10-p15
[3]  
Agras PI(2007)Modified RIFLE criteria in critically ill children with acute kidney injury Kidney Int 71 1028-1035
[4]  
Derbent M(2010)Lung dysfunction following cardiopulmonary bypass J Card Surg 25 47-55
[5]  
Ozcay F(1994)The American-European Consensus Conference on ARDS. Definitions, mechanisms, relevant outcomes, and clinical trial coordination Am J Respir Crit Care Med 149 818-824
[6]  
Baskin E(2006)Comparison of the inflammatory response between miniaturized and standard CPB circuits in aortic valve surgery Eur J Cardiothorac Surg 29 699-702
[7]  
Turkoglu S(2013)In-line filtration minimizes organ dysfunction: new aspects from a prospective, randomized, controlled trial BMC Pediatr 13 21-392
[8]  
Aldemir D(2014)Marked changes in platelet count and function following pediatric congenital heart surgery Paediatr Anaesth 24 386-874
[9]  
Tokel K(1992)American-College of Chest Physicians Society of Critical Care Medicine Consensus Conference—definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis Crit Care Med 20 864-140
[10]  
Saatci U(2005)The systemic inflammatory response syndrome and cardiopulmonary bypass Int J Surg 3 129-1403