Finite element analysis of idealised unit cell cancellous structure based on morphological indices of cancellous bone

被引:0
|
作者
Mohammed Rafiq Abdul Kadir
Ardiyansyah Syahrom
Andreas Öchsner
机构
[1] Universiti Teknologi Malaysia,Medical Implant Technology Group (MEDITEG), Faculty of Biomedical Engineering and Health Sciences
[2] Universiti Teknologi Malaysia,Faculty of Mechanical Engineering
来源
Medical & Biological Engineering & Computing | 2010年 / 48卷
关键词
Cancellous bone; Idealised architecture; Finite element analyses;
D O I
暂无
中图分类号
学科分类号
摘要
Human bones can be categorised into one of two types—the compact cortical and the porous cancellous. Whilst the cortical is a solid structure macroscopically, the structure of cancellous bone is highly complex with plate-like and strut-like structures of various sizes and shapes depending on the anatomical site. Reconstructing the actual structure of cancellous bone for defect filling is highly unfeasible. However, the complex structure can be simplified into an idealised structure with similar properties. In this study, two idealised architectures were developed based on morphological indices of cancellous bone: the tetrakaidecahedral and the prismatic. The two architectures were further subdivided into two types of microstructure, the first consists of struts only and the second consists of a combination of plates and struts. The microstructures were transformed into finite element models and displacement boundary condition was applied to all four idealised cancellous models with periodic boundary conditions. Eight unit cells extracted from the actual cancellous bone obtained from micro-computed tomography were also analysed with the same boundary conditions. Young’s modulus values were calculated and comparison was made between the idealised and real cancellous structures. Results showed that all models with a combination of plates and struts have higher rigidity compared to the one with struts only. Values of Young’s modulus from eight unit cells of cancellous bone varied from 42 to 479 MPa with an average of 234 MPa. The prismatic architecture with plates and rods closely resemble the average stiffness of a unit cell of cancellous bone.
引用
收藏
页码:497 / 505
页数:8
相关论文
共 32 条
  • [21] Three dimensional stereolithography models of cancellous bone structures from μCT data:: testing and validation of finite element results
    Dobson, CA
    Sisias, G
    Phillips, R
    Fagan, MJ
    Langton, CM
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H3) : 481 - 484
  • [22] Micro-CT based finite element models of cancellous bone predict accurately displacement once the boundary condition is well replicated: A validation study
    Chen, Yuan
    Dall'Ara, Enrico
    Sales, Erika
    Manda, Krishnagoud
    Wallace, Robert
    Pankaj, Pankaj
    Viceconti, Marco
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 65 : 644 - 651
  • [23] Gaussian random field-based characterization and reconstruction of cancellous bone microstructure considering the constraint of correlation structure
    He, Lei
    Zhao, Moxin
    Cheung, Jason Pui Yin
    Zhang, Teng
    Ren, Xiaodan
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 152
  • [24] Mechanistic Analysis of Porous Iron Scaffold Degradation in Cancellous Bone Structure Subjected to Dynamic Simulated Body Fluid
    Noordin, Muhammad Azfar
    Yusop, Abdul Hakim Md
    Syahrom, Ardiyansyah
    Md Saad, Amir Putra
    JOURNAL OF BIONIC ENGINEERING, 2025, 22 (01) : 306 - 321
  • [25] Development of selective laser melting irregular open-cell titanium lattice structure to mimic the human cancellous bone
    Bautin, Vasily A.
    Bardin, Ilya, V
    Yudin, Artem, V
    Svistunov, Evgeny, V
    Bazhenov, Vyacheslav E.
    Rytov, Ruslan A.
    PROGRESS IN ADDITIVE MANUFACTURING, 2022, 7 (06) : 1287 - 1295
  • [26] Development of selective laser melting irregular open-cell titanium lattice structure to mimic the human cancellous bone
    Vasily A. Bautin
    Ilya V. Bardin
    Artem V. Yudin
    Evgeny V. Svistunov
    Vyacheslav E. Bazhenov
    Ruslan A. Rytov
    Progress in Additive Manufacturing, 2022, 7 : 1287 - 1295
  • [27] Finite element calculated uniaxial apparent stiffness is a consistent predictor of uniaxial apparent strength in human vertebral cancellous bone tested with different boundary conditions
    Yeni, YN
    Fyhrie, DP
    JOURNAL OF BIOMECHANICS, 2001, 34 (12) : 1649 - 1654
  • [28] A Validated Skeleton-based Finite Element Mesh for Parametric Analysis of Trabecular Bone Competence
    Vanderoost, J.
    Jaecques, S. V. N.
    Van der Perre, G.
    Boonen, S.
    D'hooge, J.
    Lauriks, W.
    van Lenthe, G. H.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 1777 - 1780
  • [29] Differences in subchondral trabecular bone microstructure and finite element analysis-based biomechanical properties between osteoporosis and osteoarthritis
    He, Zihao
    Chu, Linyang
    Liu, Xuqiang
    Han, Xuequan
    Zhang, Kai
    Yan, Mengning
    Li, Xiaofeng
    Yu, Zhifeng
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 24 : 39 - 45
  • [30] Need for CT-based bone density modelling in finite element analysis of a shoulder arthroplasty revealed through a novel method for result analysis
    Pomwenger, Werner
    Entacher, Karl
    Resch, Herbert
    Schuller-Goetzburg, Peter
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 (05): : 421 - 430