Application of infrared spectroscopy to monitoring gas insulated high-voltage equipment: electrode material-dependent SF6 decomposition

被引:0
|
作者
R. Kurte
C. Beyer
H. Heise
D. Klockow
机构
[1] Institute of Spectrochemistry and Applied Spectroscopy,
[2] University of Dortmund,undefined
[3] Bunsen-Kirchhoff-Str. 11,undefined
[4] 44139 Dortmund,undefined
来源
关键词
Fourier transform infrared spectroscopy Trace gas analysis Sulfur hexafluoride decomposition By-product monitoring Partial least-squares calibration;
D O I
暂无
中图分类号
学科分类号
摘要
Sulfur hexafluoride is a chemically inert gas which is used in gas insulated substations (GIS) and other high-voltage equipment, leading to a significant enhancement of apparatus lifetime and reductions in installation size and maintenance requirements compared to conventional air insulated substations. However, component failures due to aging of the gas through electrical discharges may occur, and on-site monitoring for risk assessment is needed. Infrared spectroscopy was used for the analysis of gaseous by-products generated from electrical discharges in sulfur hexafluoride gas. An infrared monitoring system was developed using a micro-cell coupled to an FTIR spectrometer by silver halide fibers. Partial least-squares calibration was applied by using a limited number of optimally selected spectral variables. Emphasis was placed on the determination of main decomposition products, such as SOF2, SOF4, and SO2F2. Besides the different electrical conditions, the material of the plane counter electrode of the discharge chamber was also varied between silver, aluminum, copper, tungsten, or tungsten/copper alloy. For the spark experiments the point electrode was the same material as chosen for the plane electrode, whereas for partial discharges a stainless steel needle was employed. Complementary investigations on the chemical composition within the solid counter electrode material by secondary neutral mass spectrometry (SNMS) were also carried out. Under sparking conditions, the electrode material plays an important role in the decomposition rates of the gas-phase, but no relevant material dependence could be observed under partial discharge conditions.
引用
收藏
页码:639 / 646
页数:7
相关论文
共 50 条
  • [21] Simulation and Experiment on SF6 Gas Decomposition Detection Based on Infrared Absorption Spectroscopy
    Ye, Rixin
    Dong, Ming
    Ma, Ao
    Xie, Jiacheng
    Zhou, Jierui
    Huang, Wenguang
    Ren, Ming
    2017 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENON (CEIDP), 2017, : 249 - 252
  • [22] The research of temperature properties of photoacoustic spectroscopy detection for SF6 decomposition products in gas insulated switchgear
    Luo, J.
    Fang, Y. H.
    Su, Z. X.
    Li, D. C.
    Zhao, Y. D.
    Wang, A. J.
    Wu, J.
    Cui, F. X.
    Li, Y. Y.
    ANALYTICAL METHODS, 2015, 7 (09) : 3806 - 3813
  • [23] SCHLIERENINTERFEROMETRIC INVESTIGATIONS OF THE GAS FLOW OCCURRING IN HIGH-VOLTAGE SF6 SWITCHGEAR.
    Mentel, Juergen
    Siemens Forschungs- und Entwicklungsberichte/Siemens Research and Development Reports, 1975, 4 (06): : 380 - 388
  • [24] Novel Gas-Sensitive Material for Monitoring the Status of SF6 Gas-Insulated Switches: Gese Monolayer
    Qian, Guochao
    Hu, Xiqian
    Chen, Weigen
    Zhou, Qu
    CHEMOSENSORS, 2022, 10 (07)
  • [25] Low Jitter, High Voltage, Repetitive Laser Triggered SF6 Gas Insulated Spark Gaps
    Hegeler, Frank
    Myers, Matthew C.
    Wolford, Matthew F.
    Sethian, John D.
    Fielding, Andrew M.
    PROCEEDINGS OF THE 2012 IEEE INTERNATIONAL POWER MODULATOR AND HIGH VOLTAGE CONFERENCE, 2012, : 128 - 131
  • [26] Compact QEPAS humidity sensor in SF6 buffer gas for high-voltage gas power systems
    Yin, Xukun
    Dong, Lei
    Wu, Hongpeng
    Gao, Miao
    Zhang, Le
    Zhang, Xueshi
    Liu, Lixian
    Shao, Xiaopeng
    Tittel, Frank K.
    PHOTOACOUSTICS, 2022, 25
  • [27] Combination of emission spectroscopy and fast imagery to characterize high-voltage SF6 circuit breakers
    Hartinger, KT
    Pierre, L
    Cahen, C
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1998, 31 (19) : 2566 - 2576
  • [28] Review of decomposition characteristics of eco-friendly gas insulating medium for high-voltage gas-insulated equipment
    Xiao, Song
    Shi, ShengYao
    Li, Yi
    Ye, Fanchao
    Li, Yalong
    Tian, Shuangshuang
    Tang, Ju
    Zhang, Xiaoxing
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2021, 54 (37)
  • [29] Interruption Characteristics of High-voltage Hybrid Circuit Breaker Based on the Alternative of SF6 Gas
    Cheng X.
    Chen Z.
    Ge G.
    Jiao L.
    Liao M.
    Gaodianya Jishu, 12 (3862-3868): : 3862 - 3868
  • [30] A real gas model for numerical flow analysis in a high-voltage SF6 circuit breaker
    Bosovic, B.
    Beslija, D.
    Kim, M. H.
    Torlak, M.
    Dzaferovic, E.
    Kapetanovic, M.
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON TURBULENCE HEAT AND MASS TRANSFER (THMT-15), 2015, : 767 - 770