Validation of the Mobius system for patient-specific quality assurance using introduced intentional errors

被引:0
|
作者
Ivy Win Long Au
Laura Ciurlionis
Neil Campbell
Daniel Goodwin
机构
[1] Auckland City Hospital,
来源
Australasian Physical & Engineering Sciences in Medicine | 2017年 / 40卷
关键词
Patient specific QA; Treatment verification; VMAT; Gamma analysis; Introduced errors; Mobius; ArcCHECK; 3DVH;
D O I
暂无
中图分类号
学科分类号
摘要
Mobius3D and MobiusFX are model-based verification tools for treatment plan dose calculation and treatment delivery. The software facilitates patient-specific quality assurance by extracting data from linear accelerator treatment log files and performing a 3D dose calculation on the original patient CT dataset using an independent collapsed cone algorithm. In this study, we evaluate the ability of the Mobius system to detect linear accelerator-related errors compared with existing measurement-based systems, namely the ArcCHECK® and 3DVH® systems. Three original treatment plans and 47 plans with introduced delivery errors, for a total of 50 plan deliveries, were investigated. The results from this study demonstrated comparable gamma passing rates and error detectability between the Mobius and ArcCHECK® systems while the 3DVH system generally exhibited a lower sensitivity. This work also demonstrated the ability of the Mobius system to detect delivery errors of down to 2° collimator rotation, 1 mm MLC bank offset and 10 mm collimator jaw offset.
引用
收藏
页码:181 / 189
页数:8
相关论文
共 50 条
  • [21] Assessment of the Dosimetric Performance of the Mobius3D against Portal Dose Measurements in Patient-specific Quality Assurance
    Labagnoy, Yasmine Joy M.
    Oonsiri, Sornjarod
    Vimolnoch, Mananchaya
    Kingkaew, Sakda
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (04) : 350 - 357
  • [22] Development and validation of a comprehensive patient-specific quality assurance program for a novel stereotactic radiation delivery system for breast lesions
    Becker, Stewart J.
    Niu, Ying
    Mutaf, Yildirim
    Chen, Shifeng
    Poirier, Yannick
    Nichols, Elizabeth M.
    Yi, ByongYong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (12): : 138 - 148
  • [23] Patient-specific quality assurance and plan dose errors on breast intensity-modulated proton therapy
    Liu, Chunbo
    Zheng, Dandan
    Bradley, Julie A.
    Vega, Raymond B. Mailhot
    Li, Zuofeng
    Mendenhall, Nancy P.
    Liang, Xiaoying
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 84 - 91
  • [24] Dosimetric Validation for Patient-specific Quality Assurance using the Delta44 Phantom with Volumetric Modulated Arc Therapy
    Arino Gil, A.
    Calvo, O.
    Gutierrez, A.
    Papanikolau, N.
    Hdez-Armas, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S717 - S717
  • [25] Validation and Implementation of Model-Based Patient Specific Quality Assurance Using Mobius3D and MobiusFX in a Clinical Setting
    Galavis, P.
    Osterman, K.
    Jozsef, G.
    Becker, S.
    Dewyngaert, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 350 - 350
  • [26] Patient-specific quality assurance method for VMAT treatment delivery
    Schreibmann, Eduard
    Dhabaan, Anees
    Elder, Eric
    Fox, Tim
    MEDICAL PHYSICS, 2009, 36 (10) : 4530 - 4535
  • [27] Evaluation of Patient-Specific Quality Assurance Based On Different Methods
    Yang, T.
    Qu, B.
    Dai, X.
    Xie, C.
    Xiaoshen, W.
    Cong, X.
    Wang, J.
    Xu, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2896 - 2896
  • [28] Analysis of ion beam teletherapy patient-specific quality assurance
    Liu, Xiaoli
    Deng, Yu
    Schlegel, Nicki
    Huang, Zhijie
    Moyers, Michael F.
    MEDICAL DOSIMETRY, 2019, 44 (01) : 43 - 50
  • [29] Evaluation of a Phantom for Patient-specific Quality Assurance in the MR Linac
    Baumgartl, M.
    Safarkhanlo, Y.
    Ehrbar, S.
    Wilke, L.
    Krayenbuhl, J.
    Chamberlain, M.
    Zamburlini, M.
    Guckenberger, M.
    Andratschke, N.
    Tanadini-Lang, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2021, 197 (SUPPL 1) : S33 - S34
  • [30] Survey of patient-specific quality assurance practice for IMRT and VMAT
    Chan, Gordon H.
    Chin, Lee C. L.
    Abdellatif, Ady
    Bissonnette, Jean-Pierre
    Buckley, Lesley
    Comsa, Daria
    Granville, Dal
    King, Jenna
    Rapley, Patrick L.
    Vandermeer, Aaron
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (07): : 155 - 164