Electrical storm reveals worse prognosis compared to myocardial infarction complicated by ventricular tachyarrhythmias in ICD recipients

被引:0
|
作者
Julian Müller
Michael Behnes
Tobias Schupp
Dominik Ellguth
Gabriel Taton
Linda Reiser
Niko Engelke
Martin Borggrefe
Thomas Reichelt
Armin Bollow
Ibrahim El-Battrawy
Kathrin Weidner
Seung-Hyun Kim
Christian Barth
Uzair Ansari
Dirk Große Meininghaus
Muharrem Akin
Kambis Mashayekhi
Ibrahim Akin
机构
[1] University of Heidelberg,First Department of Medicine, Faculty of Medicine Mannheim
[2] Carl-Thiem-Klinikum Cottbus,Department of Cardiology
[3] Hannover Medical School,Department of Cardiology and Angiology
[4] University Heart Center Freiburg,Department of Cardiology and Angiology II
来源
Heart and Vessels | 2021年 / 36卷
关键词
Electrical storm; Acute myocardial infarction; Ventricular tachycardia; Ventricular fibrillation; Acute heart failure; Heart failure; Sudden cardiac death; MACE; Mortality; Hospitalization;
D O I
暂无
中图分类号
学科分类号
摘要
Both acute myocardial infarction complicated by ventricular tachyarrhythmias (AMI–VTA) and electrical storm (ES) represent life-threatening clinical conditions. However, a direct comparison of both sub-groups regarding prognostic endpoints has never been investigated. All consecutive implantable cardioverter-defibrillator (ICD) recipients were included retrospectively from 2002 to 2016. Patients with ES apart from AMI (ES) were compared to patients with AMI accompanied by ventricular tachyarrhythmias (AMI–VTA). The primary endpoint was all-cause mortality at 3 years, secondary endpoints were in-hospital mortality, rehospitalization rates and major adverse cardiac event (MACE) at 3 years. A total of 198 consecutive ICD recipients were included (AMI–VTA: 56%; ST-segment elevation myocardial infarction (STEMI): 22%; non-ST-segment myocardial infarction (NSTEMI) 78%; ES: 44%). ES patients were older and had higher rates of severely reduced left ventricular ejection fraction (LVEF) < 35%. ES was associated with increased all-cause mortality at 3 years (37% vs. 19%; p = 0.001; hazard ratio [HR] = 2.242; 95% CI 2.291–3.894; p = 0.004) and with increased risk of first cardiac rehospitalization (44% vs. 12%; p = 0.001; HR = 4.694; 95% CI 2.498–8.823; p = 0.001). This worse prognosis of ES compared to AMI–VTA was still evident after multivariable adjustment (long-term all-cause mortality: HR = 2.504; 95% CI 1.093–5.739; p = 0.030; first cardiac rehospitalization: HR = 2.887; 95% CI 1.240–6.720; p = 0.014). In contrast, the rates of MACE (40% vs. 32%; p = 0.326) were comparable in both groups. At long-term follow-up of 3 years, ES was associated with higher rates of all-cause mortality and rehospitalization compared to patients with AMI–VTA.
引用
收藏
页码:1701 / 1711
页数:10
相关论文
共 19 条
  • [1] Electrical storm reveals worse prognosis compared to myocardial infarction complicated by ventricular tachyarrhythmias in ICD recipients
    Mueller, Julian
    Behnes, Michael
    Schupp, Tobias
    Ellguth, Dominik
    Taton, Gabriel
    Reiser, Linda
    Engelke, Niko
    Borggrefe, Martin
    Reichelt, Thomas
    Bollow, Armin
    El-Battrawy, Ibrahim
    Weidner, Kathrin
    Kim, Seung-Hyun
    Barth, Christian
    Ansari, Uzair
    Grosse Meininghaus, Dirk
    Akin, Muharrem
    Mashayekhi, Kambis
    Akin, Ibrahim
    HEART AND VESSELS, 2021, 36 (11) : 1701 - 1711
  • [2] Electrical storm is associated with impaired prognosis compared to ventricular tachyarrhythmias
    Behnes, Michael
    Mueller, Julian
    Ellguth, Dominik
    Schupp, Tobias
    Taton, Gabriel
    Reiser, Linda
    Engelke, Niko
    Reichelt, Thomas
    Bollow, Armin
    Kim, Seung-Hyun
    Barth, Christian
    Saleh, Ahmad
    Rusnak, Jonas
    Weidner, Kathrin
    Nienaber, Christoph A.
    Mashayekhi, Kambis
    Akin, Muharrem
    Bertsch, Thomas
    Weiss, Christel
    Borggrefe, Martin
    Akin, Ibrahim
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 292 : 119 - 125
  • [3] Electrical Storm Has Worse Prognosis Compared to Sustained Ventricular Tachycardia after VT Ablation
    Mueller, Julian
    Chakarov, Ivaylo
    Halbfass, Philipp
    Nentwich, Karin
    Ene, Elena
    Berkovitz, Artur
    Sonne, Kai
    Barth, Sebastian
    Waechter, Christian
    Schupp, Tobias
    Behnes, Michael
    Akin, Ibrahim
    Deneke, Thomas
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (07)
  • [4] Electrical Storm in ICD Recipients with Arrhythmogenic Right Ventricular Cardiomyopathy
    Yin, Kang
    Ding, Ligang
    Hua, Wei
    Zhang, Shu
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (06): : 683 - 692
  • [5] Risk factors and prognostic role of an electrical storm in patients after myocardial infarction with an implanted ICD for secondary prevention
    Kwasniewski, Wojciech
    Filipecki, Artur
    Orszulak, Michal
    Orszulak, Witold
    Urbanczyk, Dagmara
    Roczniok, Robert
    Trusz-Gluza, Maria
    Mizia-Stec, Katarzyna
    ARCHIVES OF MEDICAL SCIENCE, 2018, 14 (03) : 500 - 509
  • [6] Is electrical storm in ICD patients the sign of a dying heart? Outcome of patients with clusters of ventricular tachyarrhythmias
    Greene, M
    Newman, D
    Geist, M
    Paquette, M
    Heng, D
    Dorian, P
    EUROPACE, 2000, 2 (03): : 263 - 269
  • [7] A Refractory Electrical Storm after Acute Myocardial Infarction: The Role of Temporary Ventricular Overdrive Pacing as a Bridge to ICD Implantation
    Meter, Mijo
    Borovac, Josip Andelo
    PATHOPHYSIOLOGY, 2024, 31 (01) : 44 - 51
  • [8] RISK STRATIFICATION AND PROGNOSIS OF PATIENTS TREATED WITH AMIODARONE FOR MALIGNANT VENTRICULAR TACHYARRHYTHMIAS AFTER MYOCARDIAL-INFARCTION
    PROCLEMER, A
    FACCHIN, D
    VANUZZO, D
    FERUGLIO, GA
    CARDIOVASCULAR DRUGS AND THERAPY, 1993, 7 (04) : 683 - 689
  • [9] Management of electrical storm of unstable ventricular tachycardia in post myocardial infarction patients: A single centre experience
    Rao, B. Hygriv
    Azam, Mohammed Sadiq
    Manik, Geetesh
    INDIAN HEART JOURNAL, 2018, 70 (02) : 289 - 295
  • [10] Outcomes in patients with sustained ventricular tachyarrhythmias occurring within 48 h of acute myocardial infarction: when is ICD appropriate?
    Liang, Jackson J.
    Hodge, David O.
    Mehta, Ramila A.
    Russo, Andrea M.
    Prasad, Abhiram
    Cha, Yong-Mei
    EUROPACE, 2014, 16 (12): : 1759 - 1766