The influence of water/air cooling on collateral tissue damage using a diode laser with an innovative pulse design (micropulsed mode)—an in vitro study

被引:0
作者
F. Beer
W. Körpert
A. G. Buchmair
H. Passow
A. Meinl
P. Heimel
A. Moritz
机构
[1] Medical University Vienna,Department of Conservative Dentistry, Dental School
[2] Danube University Krems,Department of Environmental and Medical Sciences, Centre for Interdisciplinary Dentistry
[3] Ludwig Boltzmann Institute for Experimental and Clinical Traumatology,Austrian Cluster for Tissue Regeneration, Histology
[4] Medical University of Vienna,Karl Donath Laboratory for Hard Tissue and Biomaterial Research, Department of Oral Surgery
来源
Lasers in Medical Science | 2013年 / 28卷
关键词
Diode laser; Thermal damage; Micropulsed; Soft tissue; Surgery;
D O I
暂无
中图分类号
学科分类号
摘要
Since the diode laser is a good compromise for the daily use in dental offices, finding usage in numerous dental indications (e.g., surgery, periodontics, and endodontics), the minimization of the collateral damage in laser surgery is important to improve the therapeutical outcome. The aim of this study was to investigate the effect of water/air cooling on the collateral thermal soft tissue damage of 980-nm diode laser incisions. A total of 36 mechanically executed laser cuts in pork liver were made with a 980-nm diode laser in micropulsed mode with three different settings of water/air cooling and examined by histological assessment to determine the area and size of carbonization, necrosis, and reversible tissue damage as well as incision depth and width. In our study, clearly the incision depth increased significantly under water/air cooling (270.9 versus 502.3 μm—test group 3) without significant changes of incision width. In test group 2, the total area of damage was significantly smaller than in the control group (in this group, the incision depth increases by 65 %). In test group 3, the total area of damage was significantly higher (incision depth increased by 85 %), but the bigger part of it represented a reversible tissue alteration leaving the amount of irreversible damage almost the same as in the control group. This first pilot study clearly shows that water/air cooling in vitro has an effect on collateral tissue damage. Further studies will have to verify, if the reduced collateral damage we have proved in this study can lead to accelerated wound healing. Reduction of collateral thermal damage after diode laser incisions is clinically relevant for promoted wound healing.
引用
收藏
页码:965 / 971
页数:6
相关论文
共 44 条
[31]  
Polanyi TG(undefined)Use of the water absorption spectrum to quantify tissue chromophore concentration changes in near-infrared spectroscopy undefined undefined undefined-undefined
[32]  
Bar-Am A(undefined)A multi-wavelength spectrophotometric method for the simultaneous determination of five haemoglobin derivatives undefined undefined undefined-undefined
[33]  
Fitzpatrick RE(undefined)The absorption spectra of hemoglobin and its derivatives in the visible and near infra-red regions undefined undefined undefined-undefined
[34]  
Ruiz-Esparza J(undefined)Diode laser (808 nm) applied to oral soft tissue lesions: a retrospective study to assess histopathological diagnosis and evaluate physical damage undefined undefined undefined-undefined
[35]  
Goldman MP(undefined)Re-oxygenation of haemoglobin in livores after post-mortem exposure to a cold environment undefined undefined undefined-undefined
[36]  
Iaria G(undefined)undefined undefined undefined undefined-undefined
[37]  
Matcher SJ(undefined)undefined undefined undefined undefined-undefined
[38]  
Matcher SJ(undefined)undefined undefined undefined undefined-undefined
[39]  
Cope M(undefined)undefined undefined undefined undefined-undefined
[40]  
Delpy DT(undefined)undefined undefined undefined undefined-undefined